Current/Voltage Transducer Monitors
Explore Current/Voltage Transducer Monitors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output | Isolation | Response Time | Accuracy | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RISH CON-CV-AVG-07-F-V-01-HVOLTAGE TRANSDUCER 0~240V I/P |
2,922 |
|
Datasheet | - | Bulk | Active | Voltage Transducer | 0 ~ 240VAC | 0 ~ 10VDC | - | 250ms | - | 40 ~ 300VAC/DC | DIN Rail | Screw Terminal | 0°C ~ 45°C | UL |
|
RISH CON-CA-AVG-05-F-I-02-HCURRENT TRANSDUCER 4~20 MA O/P |
1,775 |
|
Datasheet | - | Bulk | Active | Current Transducer | 0 ~ 5A | 4 ~ 20mA | - | 250ms | - | 40 ~ 300VAC/DC | DIN Rail | Screw Terminal | 0°C ~ 45°C | UL |
|
RISH CON-CV-AVG-14-F-I-02-HVOLTAGE TRANSDUCER 4~20 MA O/P |
1,561 |
|
Datasheet | - | Bulk | Active | Voltage Transducer | 0 ~ 500VAC | 4 ~ 20mA | - | 250ms | - | 40 ~ 300VAC/DC | DIN Rail | Screw Terminal | 0°C ~ 45°C | UL |
|
RISH CON-CV-AVG-05-F-V-01-LVOLTAGE TRANSDUCER 0~220V I/P |
3,521 |
|
Datasheet | - | Bulk | Active | Voltage Transducer | 0 ~ 220VAC | 0 ~ 10VDC | - | 250ms | - | 24 ~ 60VAC/DC | DIN Rail | Screw Terminal | 0°C ~ 45°C | UL |
|
RISH CON-CV-AVG-04-F-V-01-LVOLTAGE TRANSDUCER 0~150V I/P |
3,923 |
|
Datasheet | - | Bulk | Active | Voltage Transducer | 0 ~ 150VAC | 0 ~ 10VDC | - | 250ms | - | 24 ~ 60VAC/DC | DIN Rail | Screw Terminal | 0°C ~ 45°C | UL |
|
RISH CON-CA-AVG-01-F-I-02-HCURRENT TRANSDUCER 4~20 MA O/P |
4,050 |
|
Datasheet | - | Bulk | Active | Current Transducer | 0 ~ 1A | 4 ~ 20mA | - | 250ms | - | 40 ~ 300VAC/DC | DIN Rail | Screw Terminal | 0°C ~ 45°C | UL |
|
CM21-V7GF550000000VOLTAGE TRANSDUCER 0-300V 4-20MA |
2,486 |
|
Datasheet | - | Bulk | Active | Voltage Transducer | 0 ~ 300VAC | 4 ~ 20mA | - | 250ms | - | 24 ~ 60VAC/DC | DIN Rail | Screw Terminal | 0°C ~ 45°C | CE, UL |
|
CR4620-250TRANSDUCER VOLTAGE 24VDC |
4,886 |
|
Datasheet | CR4600 | Bulk | Active | Average RMS AC Voltage Transducer | 0 ~ 250VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
CR4620-50TRANSDUCER VOLTAGE 24VDC |
1,236 |
|
Datasheet | CR4600 | Bulk | Active | Average RMS AC Voltage Transducer | 0 ~ 50VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
CR4620-500TRANSDUCER VOLTAGE 24VDC |
2,522 |
|
Datasheet | CR4600 | Bulk | Active | Average RMS AC Voltage Transducer | 0 ~ 500VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
DCSA20TRANSDUCER CURRENT 10-30VDC |
3,903 |
|
Datasheet | DCSA | Bulk | Active | Current Transducer | 0 ~ 20mA | 4 ~ 20mA, 1 ~ 10VDC | Not Isolated | 300ms | ±0.25% | 10 ~ 30VDC | DIN Rail | Screw Terminal | -30°C ~ 60°C | CE, CSA, UL |
|
DCSA5TRANSDUCER CURRENT 10-30VDC |
2,948 |
|
Datasheet | DCSA | Bulk | Active | Current Transducer | 0 ~ 5mA | 4 ~ 20mA, 1 ~ 10VDC | Not Isolated | 300ms | ±0.25% | 10 ~ 30VDC | DIN Rail | Screw Terminal | -30°C ~ 60°C | CE, CSA, UL |
|
CR4810-250TRANSDUCER VOLTAGE 24VDC |
2,032 |
|
Datasheet | CR4800 | Box | Active | Average RMS AC Voltage Transducer | 0 ~ 250VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
CR4810-150TRANSDUCER VOLTAGE 24VDC |
4,315 |
|
Datasheet | CR4800 | Bulk | Active | Average RMS AC Voltage Transducer | 0 ~ 150VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
CR4810-500TRANSDUCER VOLTAGE 24VDC |
2,481 |
|
Datasheet | CR4800 | Bulk | Active | Average RMS AC Voltage Transducer | 0 ~ 500VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
CR4810-50TRANSDUCER VOLTAGE 24VDC |
2,459 |
|
Datasheet | CR4800 | Bulk | Active | Average RMS AC Voltage Transducer | 0 ~ 50VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
TCSA20TRANSDUCER CURRENT 10-30VDC |
3,855 |
|
Datasheet | TCSA | Bulk | Active | Current Transducer | 0 ~ 20A | 4 ~ 20mA | - | 300ms | ±0.25% | 10 ~ 30VDC | Chassis Mount | Quick Connect - 0.250" (6.3mm) | -30°C ~ 60°C | CE, CSA, UL |
|
TCSA50TRANSDUCER CURRENT 10-30VDC |
2,899 |
|
Datasheet | TCSA | Bulk | Active | Current Transducer | 0 ~ 50A | 4 ~ 20mA | - | 300ms | ±0.25% | 10 ~ 30VDC | Chassis Mount | Quick Connect - 0.250" (6.3mm) | -30°C ~ 60°C | CE, CSA, UL |
|
CR4820-150TRANSDUCER VOLTAGE 24VDC |
1,929 |
|
Datasheet | CR4800 | Bulk | Active | Average RMS AC Voltage Transducer | 0 ~ 150VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
CR4820-250TRANSDUCER VOLTAGE 24VDC |
3,950 |
|
Datasheet | CR4800 | Bulk | Active | Average RMS AC Voltage Transducer | 0 ~ 250VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
Frequently Asked Questions
What are Current/Voltage Transducer Monitors components used for?
Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current/Voltage Transducer Monitors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?