Current/Voltage Transducer Monitors
Explore Current/Voltage Transducer Monitors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output | Isolation | Response Time | Accuracy | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ISOBLOCK V-4C (300V 10V)TRANSDUCER VOLTAGE 9-28VDC |
1,601 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±300V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-4C (500V 10V)TRANSDUCER VOLTAGE 9-28VDC |
1,977 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±500V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-4C (100V 10V)TRANSDUCER VOLTAGE 9-28VDC |
3,385 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±100V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
CR4620-150TRANSDUCER VOLTAGE 24VDC |
3,391 |
|
Datasheet | CR4600 | Box | Active | Average RMS AC Voltage Transducer | 0 ~ 150VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
|
CR4510-150TRANSDUCER VOLTAGE 24VDC |
1,523 |
|
Datasheet | CR4500 | Bulk | Active | True RMS AC Voltage Transducer | 0 ~ 150VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
ISOBLOCK I-FG-1C (15A 10V)TRANSDUCER CURRENT 9-28VDC |
2,079 |
|
Datasheet | IsoBlock I-FG | Box | Active | Current Transducer | 0 ~ 15A | ±10V | 1200V (Working) | 5µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK I-FG-1C (25A 10V)TRANSDUCER CURRENT 9-28VDC |
4,159 |
|
Datasheet | IsoBlock I-FG | Box | Active | Current Transducer | 0 ~ 25A | ±10V | 1200V (Working) | 5µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
|
2810612TRANSDUCER CURRENT 24VDC |
4,555 |
|
Datasheet | MCR | Bulk | Active | Current Transducer | 0 ~ 5A | 0 ~ 20mA | 4000VAC (Test) | - | - | 24VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C | ATEX, cULus |
|
2308043TRANSDUCER CURRENT 24VDC |
2,840 |
|
Datasheet | MCR | Bulk | Active | Current Transducer | 0 ~ 300A | 4 ~ 20mA | 300VAC (Working), 3500VAC (Test) | 150ms | - | 24VDC | Chassis Mount, DIN Rail | Spring Terminal | -40°C ~ 65°C | CE, cULus |
|
|
2813486TRANSDUCER CURRENT 20-30VDC |
3,557 |
|
Datasheet | MCR | Bulk | Active | Current Transducer | 0 ~ 100A | 4 ~ 20mA | 5000VAC (Test) | 340ms | - | 20 ~ 30VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C | CE, cULus |
|
2810625TRANSDUCER CURR 19.2-253VAC/DC |
3,522 |
|
Datasheet | MCR | Bulk | Active | Current Transducer | 0 ~ 5A | 0 ~ 20mA | 4000VAC (Test) | 200ms | - | 19.2 ~ 253VAC/DC | DIN Rail | Screw Terminal | -20°C ~ 65°C | ATEX, cULus |
|
2308085TRANSDUCER CURRENT 24VDC |
2,303 |
|
Datasheet | MCR | Bulk | Active | Current Transducer | 0 ~ 500A | 4 ~ 20mA | 300VAC (Working), 3500VAC (Test) | 150ms | - | 24VDC | DIN Rail | Spring Terminal | -40°C ~ 65°C | CE, cULus |
|
ISOBLOCK V-1C (1000V 5V)TRANSDUCER VOLTAGE 9-28VDC |
1,557 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±1000V | ±5V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-1C (500V 5V)TRANSDUCER VOLTAGE 9-28VDC |
1,996 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±500V | ±5V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
TCSA10TRANSDUCER CURRENT 10-30VDC |
4,211 |
|
Datasheet | TCSA | Bulk | Active | Current Transducer | 0 ~ 10A | 4 ~ 20mA | - | 300ms | ±0.25% | 10 ~ 30VDC | Chassis Mount | Quick Connect - 0.250" (6.3mm) | -30°C ~ 60°C | CE, CSA, UL |
|
TCSA5TRANSDUCER CURRENT 10-30VDC |
2,071 |
|
Datasheet | TCSA | Bulk | Active | Current Transducer | 0 ~ 5A | 4 ~ 20mA | - | 300ms | ±0.25% | 10 ~ 30VDC | Chassis Mount | Quick Connect - 0.250" (6.3mm) | -30°C ~ 60°C | CE, CSA, UL |
|
DCSA50TRANSDUCER CURRENT 10-30VDC |
1,584 |
|
Datasheet | DCSA | Bulk | Active | Current Transducer | 0 ~ 50mA | 4 ~ 20mA, 1 ~ 10VDC | Not Isolated | 300ms | ±0.25% | 10 ~ 30VDC | DIN Rail | Screw Terminal | -30°C ~ 60°C | CE, CSA, UL |
|
|
E83-2050TRANSDUCER CURRENT 10-40VDC |
4,603 |
|
Datasheet | E83 | Bag | Active | Current Transducer | 0 ~ 50A | 4 ~ 20mA | - | 200ms | ±2% | 10 ~ 40VDC | DIN Rail | Screw Terminal | -20°C ~ 50°C | CE, UL |
|
|
CR4510-50TRANSDUCER VOLTAGE 24VDC |
4,944 |
|
Datasheet | CR4500 | Bulk | Active | True RMS AC Voltage Transducer | 0 ~ 50VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
ENTUBE SE (1500V 10V)TRANSDUCER VOLTAGE DIVIDER |
2,390 |
|
Datasheet | Entube SE | Box | Active | Voltage Transducer | ±1500V | ±10V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
Frequently Asked Questions
What are Current/Voltage Transducer Monitors components used for?
Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current/Voltage Transducer Monitors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.