Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Input Range Output Isolation Response Time Accuracy Voltage - Supply Mounting Type Termination Style Operating Temperature Approval Agency
ISOBLOCK V-4C (300V 10V) Verivolt LLC

ISOBLOCK V-4C (300V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

1,601
Datasheet IsoBlock V Box Active Voltage Transducer ±300V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-4C (500V 10V) Verivolt LLC

ISOBLOCK V-4C (500V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

1,977
Datasheet IsoBlock V Box Active Voltage Transducer ±500V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-4C (100V 10V) Verivolt LLC

ISOBLOCK V-4C (100V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

3,385
Datasheet IsoBlock V Box Active Voltage Transducer ±100V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
CR4620-150 CR Magnetics Inc.

CR4620-150

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

3,391
Datasheet CR4600 Box Active Average RMS AC Voltage Transducer 0 ~ 150VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4510-150 CR Magnetics Inc.

CR4510-150

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

1,523
Datasheet CR4500 Bulk Active True RMS AC Voltage Transducer 0 ~ 150VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
ISOBLOCK I-FG-1C (15A 10V) Verivolt LLC

ISOBLOCK I-FG-1C (15A 10V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

2,079
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 15A ±10V 1200V (Working) 5µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK I-FG-1C (25A 10V) Verivolt LLC

ISOBLOCK I-FG-1C (25A 10V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

4,159
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 25A ±10V 1200V (Working) 5µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
2810612 Phoenix Contact

2810612

TRANSDUCER CURRENT 24VDC

Phoenix Contact

4,555
Datasheet MCR Bulk Active Current Transducer 0 ~ 5A 0 ~ 20mA 4000VAC (Test) - - 24VDC DIN Rail Screw Terminal -20°C ~ 60°C ATEX, cULus
2308043 Phoenix Contact

2308043

TRANSDUCER CURRENT 24VDC

Phoenix Contact

2,840
Datasheet MCR Bulk Active Current Transducer 0 ~ 300A 4 ~ 20mA 300VAC (Working), 3500VAC (Test) 150ms - 24VDC Chassis Mount, DIN Rail Spring Terminal -40°C ~ 65°C CE, cULus
2813486 Phoenix Contact

2813486

TRANSDUCER CURRENT 20-30VDC

Phoenix Contact

3,557
Datasheet MCR Bulk Active Current Transducer 0 ~ 100A 4 ~ 20mA 5000VAC (Test) 340ms - 20 ~ 30VDC DIN Rail Screw Terminal -20°C ~ 60°C CE, cULus
2810625 Phoenix Contact

2810625

TRANSDUCER CURR 19.2-253VAC/DC

Phoenix Contact

3,522
Datasheet MCR Bulk Active Current Transducer 0 ~ 5A 0 ~ 20mA 4000VAC (Test) 200ms - 19.2 ~ 253VAC/DC DIN Rail Screw Terminal -20°C ~ 65°C ATEX, cULus
2308085 Phoenix Contact

2308085

TRANSDUCER CURRENT 24VDC

Phoenix Contact

2,303
Datasheet MCR Bulk Active Current Transducer 0 ~ 500A 4 ~ 20mA 300VAC (Working), 3500VAC (Test) 150ms - 24VDC DIN Rail Spring Terminal -40°C ~ 65°C CE, cULus
ISOBLOCK V-1C (1000V 5V) Verivolt LLC

ISOBLOCK V-1C (1000V 5V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

1,557
Datasheet IsoBlock V Box Active Voltage Transducer ±1000V ±5V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-1C (500V 5V) Verivolt LLC

ISOBLOCK V-1C (500V 5V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

1,996
Datasheet IsoBlock V Box Active Voltage Transducer ±500V ±5V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
TCSA10 Littelfuse Inc.

TCSA10

TRANSDUCER CURRENT 10-30VDC

Littelfuse Inc.

4,211
Datasheet TCSA Bulk Active Current Transducer 0 ~ 10A 4 ~ 20mA - 300ms ±0.25% 10 ~ 30VDC Chassis Mount Quick Connect - 0.250" (6.3mm) -30°C ~ 60°C CE, CSA, UL
TCSA5 Littelfuse Inc.

TCSA5

TRANSDUCER CURRENT 10-30VDC

Littelfuse Inc.

2,071
Datasheet TCSA Bulk Active Current Transducer 0 ~ 5A 4 ~ 20mA - 300ms ±0.25% 10 ~ 30VDC Chassis Mount Quick Connect - 0.250" (6.3mm) -30°C ~ 60°C CE, CSA, UL
DCSA50 Littelfuse Inc.

DCSA50

TRANSDUCER CURRENT 10-30VDC

Littelfuse Inc.

1,584
Datasheet DCSA Bulk Active Current Transducer 0 ~ 50mA 4 ~ 20mA, 1 ~ 10VDC Not Isolated 300ms ±0.25% 10 ~ 30VDC DIN Rail Screw Terminal -30°C ~ 60°C CE, CSA, UL
E83-2050 Carlo Gavazzi Inc.

E83-2050

TRANSDUCER CURRENT 10-40VDC

Carlo Gavazzi Inc.

4,603
Datasheet E83 Bag Active Current Transducer 0 ~ 50A 4 ~ 20mA - 200ms ±2% 10 ~ 40VDC DIN Rail Screw Terminal -20°C ~ 50°C CE, UL
CR4510-50 CR Magnetics Inc.

CR4510-50

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

4,944
Datasheet CR4500 Bulk Active True RMS AC Voltage Transducer 0 ~ 50VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
ENTUBE SE (1500V 10V) Verivolt LLC

ENTUBE SE (1500V 10V)

TRANSDUCER VOLTAGE DIVIDER

Verivolt LLC

2,390
Datasheet Entube SE Box Active Voltage Transducer ±1500V ±10V - - ±0.2% - DIN Rail Spring Terminal -25°C ~ 70°C -
Total 1041 Record«Prev123456...53Next»
FAQ

Frequently Asked Questions

What are Current/Voltage Transducer Monitors components used for?

Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current/Voltage Transducer Monitors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Current/Voltage Transducer Monitors?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top