ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Current/Voltage Transducer Monitors

Explore Current/Voltage Transducer Monitors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Input Range Output Isolation Response Time Accuracy Voltage - Supply Mounting Type Termination Style Operating Temperature Approval Agency
ISOBLOCK V-1C (1000V 10V) Verivolt LLC

ISOBLOCK V-1C (1000V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

107
Datasheet IsoBlock V Box Active Voltage Transducer ±1000V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-1C (1500V 10V) Verivolt LLC

ISOBLOCK V-1C (1500V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

2,060
Datasheet IsoBlock V Box Active Voltage Transducer ±1500V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
AIMDC-5V-1000V Aim Dynamics

AIMDC-5V-1000V

TRANSDUCER 0-1000V:0-5VDC

Aim Dynamics

101
Datasheet AIMDC Bulk Active DC Voltage Transducer 0 ~ 1000VDC 0 ~ 5VDC - 10ms 0.005% 15 ~ 36VDC DIN Rail, Wall Mount Screw Terminal -35°C ~ 100°C -
AIMDC-420-100V Aim Dynamics

AIMDC-420-100V

TRANSDUCER 0-100V:4-20MA

Aim Dynamics

4,826
Datasheet AIMDC Bulk Active DC Voltage Transducer 0 ~ 100VDC 4 ~ 20mA - 10ms 0.005% 15 ~ 36VDC DIN Rail, Wall Mount Screw Terminal -35°C ~ 100°C -
AIMDC-5V-100V Aim Dynamics

AIMDC-5V-100V

TRANSDUCER 0-100V:0-5VDC

Aim Dynamics

3,306
Datasheet AIMDC Bulk Active DC Voltage Transducer 0 ~ 100VDC 0 ~ 5VDC - 10ms 0.005% 15 ~ 36VDC DIN Rail, Wall Mount Screw Terminal -35°C ~ 100°C -
AIMDC-420-1000V Aim Dynamics

AIMDC-420-1000V

TRANSDUCER 0-1000V:4-20MA

Aim Dynamics

4,048
Datasheet AIMDC Bulk Active DC Voltage Transducer 0 ~ 1000VDC 4 ~ 20mA - 10ms 0.005% 15 ~ 36VDC DIN Rail, Wall Mount Screw Terminal -35°C ~ 100°C -
AIMDC-10V-100V Aim Dynamics

AIMDC-10V-100V

TRANSDUCER 0-100V:0-10VDC

Aim Dynamics

2,145
Datasheet AIMDC Bulk Active DC Voltage Transducer 0 ~ 100VDC 0 ~ 10VDC - 10ms 0.005% 15 ~ 36VDC DIN Rail, Wall Mount Screw Terminal -35°C ~ 100°C -
DC1-PRO-1000V:420 Aim Dynamics

DC1-PRO-1000V:420

TRANSDUCER 0-1000V:4-20MA 0.5%

Aim Dynamics

554
Datasheet DC1-PRO Case Active DC Voltage Transducer 0 ~ 1000VDC 4 ~ 20mA 3000V, 1 minute 10ms 0.5% 15 ~ 36VDC DIN Rail, Wall Mount Screw Terminal -35°C ~ 100°C -
DC1-PRO-1500V:5V Aim Dynamics

DC1-PRO-1500V:5V

DC Voltage Transducer, Input: 0

Aim Dynamics

100
Datasheet DC1-PRO Case Active DC Voltage Transducer 0 ~ 1500VDC 0 ~ 5VDC 3000V, 1 minute 10ms 0.5% 15 ~ 36VDC DIN Rail, Wall Mount Screw Terminal -35°C ~ 100°C -
DC1-PRO-5V Aim Dynamics

DC1-PRO-5V

TRANSDUCER 0-1000V:0-5VDC 0.5%

Aim Dynamics

3,634
Datasheet DC1 Tape & Box (TB) Active DC Voltage Transducer 0 ~ 1000VDC 0 ~ 5VDC 4500V (Test) 200ms 0.005% 15 ~ 48VDC DIN Rail, Wall Mount Screw Terminal -30°C ~ 70°C -
DN-848VI-10V ICP DAS USA INC

DN-848VI-10V

8-CH 10 VDC VOLTAGE ATTEN W/ISO

ICP DAS USA INC

3,883
Datasheet DN-848VI Box Active Voltage Transducer ±10V ±10V 3000VAC (Test) - 1% 10 ~ 24VDC DIN Rail - -25°C ~ 75°C CE, FCC
DN-831I-100V-50A ICP DAS USA INC

DN-831I-100V-50A

1 CH 100V AC/DC& 50A ATTENUATOR

ICP DAS USA INC

1,915
Datasheet DN-831I-100V Box Active Current Transducer ±50A ±10V 2500V (Working) - 1% 10 ~ 30VDC DIN Rail - -25°C ~ 75°C CE, FCC
DN-843V-600V ICP DAS USA INC

DN-843V-600V

3-CH 600 VDC VOLTAGE ATTENUATOR

ICP DAS USA INC

2,943
Datasheet DN-843V Box Active Voltage Transducer ±600V ±10V 3000VAC (Test) - 1% 10 ~ 24VDC DIN Rail - -25°C ~ 75°C CE, FCC
DN-831I-100V-500A ICP DAS USA INC

DN-831I-100V-500A

1 CH 100V AC/DC& 500A ATTENUATOR

ICP DAS USA INC

3,972
Datasheet DN-831I-100V Box Active Current Transducer ±500A ±10V 2500V (Working) - 1% 10 ~ 30VDC DIN Rail - -25°C ~ 75°C CE, FCC
DC1-PRO-420 Aim Dynamics

DC1-PRO-420

TRANSDUCER 0-1000V:4-20MA 0.5%

Aim Dynamics

432
Datasheet DC1 Tape & Box (TB) Active DC Voltage Transducer 0 ~ 1000VDC 4 ~ 20mA 4500V (Test) 200ms 0.005% 15 ~ 48VDC DIN Rail, Wall Mount Screw Terminal -30°C ~ 70°C -
DC1-PRO-1500V:420 Aim Dynamics

DC1-PRO-1500V:420

TRANSDUCER 0-1000V:4-20MA 0.5%

Aim Dynamics

100
Datasheet DC1-PRO Case Active DC Voltage Transducer 0 ~ 1500VDC 4 ~ 20mA 3000V, 1 minute 10ms 0.5% 15 ~ 36VDC DIN Rail, Wall Mount Screw Terminal -35°C ~ 100°C -
DVT-1000-V01 Magnelab, Inc.

DVT-1000-V01

TRANSDUCER 0-1000V:0-1VDC 0.5%

Magnelab, Inc.

2,482
Datasheet DVT Tape & Box (TB) Active DC Voltage Transducer 0 ~ 1000VDC 0 ~ 1VDC 4500V (Test) 200ms 0.005% 15 ~ 48VDC DIN Rail Screw Terminal -30°C ~ 70°C -
DVT-1000-V05 Magnelab, Inc.

DVT-1000-V05

TRANSDUCER 0-1000V:0-5VDC 0.5%

Magnelab, Inc.

2,307
Datasheet DVT Tape & Box (TB) Active DC Voltage Transducer 0 ~ 1000VDC 0 ~ 5VDC 4500V (Test) 200ms 0.005% 15 ~ 48VDC DIN Rail Screw Terminal -30°C ~ 70°C -
DN-843VI-600V ICP DAS USA INC

DN-843VI-600V

3-CH 600 VDC VOLTAGE ATTEN W/ISO

ICP DAS USA INC

2,031
Datasheet DN-843VI Box Active Voltage Transducer ±600V ±10V 3000VAC (Test) - 1% 10 ~ 24VDC DIN Rail - -25°C ~ 75°C CE, FCC
DN-848VI-150V ICP DAS USA INC

DN-848VI-150V

8-CH 150 VDC VOLTAGE ATTEN W/ISO

ICP DAS USA INC

1,493
Datasheet DN-848VI Box Active Voltage Transducer ±150V ±10V 3000VAC (Test) - 1% 10 ~ 24VDC DIN Rail - -25°C ~ 75°C CE, FCC
Total 1041 Record«Prev1234...53Next»
FAQ

Frequently Asked Questions

What are Current/Voltage Transducer Monitors components used for?

Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current/Voltage Transducer Monitors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Current/Voltage Transducer Monitors?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top