Current/Voltage Transducer Monitors
Explore Current/Voltage Transducer Monitors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output | Isolation | Response Time | Accuracy | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ISOBLOCK V-1C (1000V 10V)TRANSDUCER VOLTAGE 9-28VDC |
107 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±1000V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-1C (1500V 10V)TRANSDUCER VOLTAGE 9-28VDC |
2,060 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±1500V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
AIMDC-5V-1000VTRANSDUCER 0-1000V:0-5VDC |
101 |
|
Datasheet | AIMDC | Bulk | Active | DC Voltage Transducer | 0 ~ 1000VDC | 0 ~ 5VDC | - | 10ms | 0.005% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
AIMDC-420-100VTRANSDUCER 0-100V:4-20MA |
4,826 |
|
Datasheet | AIMDC | Bulk | Active | DC Voltage Transducer | 0 ~ 100VDC | 4 ~ 20mA | - | 10ms | 0.005% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
AIMDC-5V-100VTRANSDUCER 0-100V:0-5VDC |
3,306 |
|
Datasheet | AIMDC | Bulk | Active | DC Voltage Transducer | 0 ~ 100VDC | 0 ~ 5VDC | - | 10ms | 0.005% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
AIMDC-420-1000VTRANSDUCER 0-1000V:4-20MA |
4,048 |
|
Datasheet | AIMDC | Bulk | Active | DC Voltage Transducer | 0 ~ 1000VDC | 4 ~ 20mA | - | 10ms | 0.005% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
AIMDC-10V-100VTRANSDUCER 0-100V:0-10VDC |
2,145 |
|
Datasheet | AIMDC | Bulk | Active | DC Voltage Transducer | 0 ~ 100VDC | 0 ~ 10VDC | - | 10ms | 0.005% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
DC1-PRO-1000V:420TRANSDUCER 0-1000V:4-20MA 0.5% |
554 |
|
Datasheet | DC1-PRO | Case | Active | DC Voltage Transducer | 0 ~ 1000VDC | 4 ~ 20mA | 3000V, 1 minute | 10ms | 0.5% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
DC1-PRO-1500V:5VDC Voltage Transducer, Input: 0 |
100 |
|
Datasheet | DC1-PRO | Case | Active | DC Voltage Transducer | 0 ~ 1500VDC | 0 ~ 5VDC | 3000V, 1 minute | 10ms | 0.5% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
DC1-PRO-5VTRANSDUCER 0-1000V:0-5VDC 0.5% |
3,634 |
|
Datasheet | DC1 | Tape & Box (TB) | Active | DC Voltage Transducer | 0 ~ 1000VDC | 0 ~ 5VDC | 4500V (Test) | 200ms | 0.005% | 15 ~ 48VDC | DIN Rail, Wall Mount | Screw Terminal | -30°C ~ 70°C | - |
|
DN-848VI-10V8-CH 10 VDC VOLTAGE ATTEN W/ISO |
3,883 |
|
Datasheet | DN-848VI | Box | Active | Voltage Transducer | ±10V | ±10V | 3000VAC (Test) | - | 1% | 10 ~ 24VDC | DIN Rail | - | -25°C ~ 75°C | CE, FCC |
|
DN-831I-100V-50A1 CH 100V AC/DC& 50A ATTENUATOR |
1,915 |
|
Datasheet | DN-831I-100V | Box | Active | Current Transducer | ±50A | ±10V | 2500V (Working) | - | 1% | 10 ~ 30VDC | DIN Rail | - | -25°C ~ 75°C | CE, FCC |
|
DN-843V-600V3-CH 600 VDC VOLTAGE ATTENUATOR |
2,943 |
|
Datasheet | DN-843V | Box | Active | Voltage Transducer | ±600V | ±10V | 3000VAC (Test) | - | 1% | 10 ~ 24VDC | DIN Rail | - | -25°C ~ 75°C | CE, FCC |
|
DN-831I-100V-500A1 CH 100V AC/DC& 500A ATTENUATOR |
3,972 |
|
Datasheet | DN-831I-100V | Box | Active | Current Transducer | ±500A | ±10V | 2500V (Working) | - | 1% | 10 ~ 30VDC | DIN Rail | - | -25°C ~ 75°C | CE, FCC |
|
DC1-PRO-420TRANSDUCER 0-1000V:4-20MA 0.5% |
432 |
|
Datasheet | DC1 | Tape & Box (TB) | Active | DC Voltage Transducer | 0 ~ 1000VDC | 4 ~ 20mA | 4500V (Test) | 200ms | 0.005% | 15 ~ 48VDC | DIN Rail, Wall Mount | Screw Terminal | -30°C ~ 70°C | - |
|
DC1-PRO-1500V:420TRANSDUCER 0-1000V:4-20MA 0.5% |
100 |
|
Datasheet | DC1-PRO | Case | Active | DC Voltage Transducer | 0 ~ 1500VDC | 4 ~ 20mA | 3000V, 1 minute | 10ms | 0.5% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
DVT-1000-V01TRANSDUCER 0-1000V:0-1VDC 0.5% |
2,482 |
|
Datasheet | DVT | Tape & Box (TB) | Active | DC Voltage Transducer | 0 ~ 1000VDC | 0 ~ 1VDC | 4500V (Test) | 200ms | 0.005% | 15 ~ 48VDC | DIN Rail | Screw Terminal | -30°C ~ 70°C | - |
|
DVT-1000-V05TRANSDUCER 0-1000V:0-5VDC 0.5% |
2,307 |
|
Datasheet | DVT | Tape & Box (TB) | Active | DC Voltage Transducer | 0 ~ 1000VDC | 0 ~ 5VDC | 4500V (Test) | 200ms | 0.005% | 15 ~ 48VDC | DIN Rail | Screw Terminal | -30°C ~ 70°C | - |
|
DN-843VI-600V3-CH 600 VDC VOLTAGE ATTEN W/ISO |
2,031 |
|
Datasheet | DN-843VI | Box | Active | Voltage Transducer | ±600V | ±10V | 3000VAC (Test) | - | 1% | 10 ~ 24VDC | DIN Rail | - | -25°C ~ 75°C | CE, FCC |
|
DN-848VI-150V8-CH 150 VDC VOLTAGE ATTEN W/ISO |
1,493 |
|
Datasheet | DN-848VI | Box | Active | Voltage Transducer | ±150V | ±10V | 3000VAC (Test) | - | 1% | 10 ~ 24VDC | DIN Rail | - | -25°C ~ 75°C | CE, FCC |
Frequently Asked Questions
What are Current/Voltage Transducer Monitors components used for?
Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current/Voltage Transducer Monitors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.