Current/Voltage Transducer Monitors
Explore Current/Voltage Transducer Monitors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output | Isolation | Response Time | Accuracy | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ENTUBE SE (50V 10V)TRANSDUCER VOLTAGE DIVIDER |
3,366 |
|
Datasheet | Entube SE | Box | Active | Voltage Transducer | ±50V | ±10V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
2813460TRANSDUCER CURRENT 20-30VDC |
1,619 |
|
Datasheet | MCR | Bulk | Active | Current Transducer | 0 ~ 200A | 0 ~ 10VDC | 5000VAC (Test) | 340ms | - | 20 ~ 30VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C | CE, cULus |
|
2906243TRANSDUCER VOLTAGE 24VDC |
4,997 |
|
Datasheet | MACX | Bulk | Active | Voltage Transducer | ±660VDC | ±10V | 5300VAC (Test) | 16ms | - | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 60°C | CE, cULus |
|
ENTUBE DE-HB (500V 10V DIFFSC)TRANSDUCER VOLTAGE 9-28VDC |
2,317 |
|
Datasheet | Entube DE-HB | Box | Active | Voltage Transducer | ±500V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ENTUBE DE-HB (1000V 10V DIFFSC)TRANSDUCER VOLTAGE 9-28VDC |
3,127 |
|
Datasheet | Entube DE-HB | Box | Active | Voltage Transducer | ±1000V | ±10V | - | 20ns | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-4C (1500V 10V)TRANSDUCER VOLTAGE 9-28VDC |
3,647 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±1500V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-4C (50V 10V)TRANSDUCER VOLTAGE 9-28VDC |
3,854 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±50V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
286-662CURRENT FLOW MONITORING MODULE D |
3,416 |
|
Datasheet | - | Box | Active | Current Transducer | 24 ~ 210mV | 0.4 ~ 3.5A | - | 0.5ms | - | 12 ~ 28VDC | Socketable | Plug In | -25°C ~ 40°C | - |
|
2810638MACX MCR-SL-CAC-12-I-UP |
3,327 |
|
Datasheet | MACX MCR | Bulk | Active | Current Transducer | 0 ~ 12A | 0 ~ 20mA | 4000VAC (Test) | 200ms | - | 19.2 ~ 253VAC/DC | DIN Rail | Screw Terminal | -20°C ~ 65°C | ATEX, EAC |
|
CR4580-150TRANSDUCER VOLTAGE 24VDC |
4,076 |
|
Datasheet | CR4500 | Box | Active | True RMS AC Voltage Transducer | 0 ~ 150VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
ISOBLOCK V-1C (1000V 10V0.1%)TRANSDUCER VOLTAGE 9-28VDC |
1,128 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±1000V | ±10V | 1500V (Working) | 2.8µs | ±0.1% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ATM130104RSHEECURRENT SENSING , CONTROL AND MO |
4,439 |
|
Datasheet | - | Tray | Active | - | 0 ~ 40A | - | - | - | 1% | - | - | - | -40°C ~ 85°C | - |
|
T201Loop Power AC Current Transducer |
2,353 |
|
Datasheet | T201 | Bulk | Active | AC Current Transducer | 5 ~ 40VAC (Configurable) | 4 ~ 20mA | 3000VAC | 100ms | ±0.2% | 5 ~ 28VDC | DIN Rail | Spring Terminal | -20°C ~ 65°C | CE, UL |
|
DN-831I-100V-200A1 CH 100V AC/DC& 200A ATTENUATOR |
1,395 |
|
Datasheet | DN-831I-100V | Box | Active | Current Transducer | ±200A | ±10V | 2500V (Working) | - | 1% | 10 ~ 30VDC | DIN Rail | - | -25°C ~ 75°C | CE, FCC |
|
AIMDC-10V-1000VTRANSDUCER 0-100V:0-10VDC |
2,847 |
|
Datasheet | AIMDC | Bulk | Active | DC Voltage Transducer | 0 ~ 1000VDC | 0 ~ 10VDC | - | 10ms | 0.005% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
CR4520-600TRANSDUCER VOLTAGE 24VDC |
1,401 |
|
Datasheet | CR4500 | Bulk | Active | True RMS AC Voltage Transducer | 0 ~ 600VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
DC1-PRO-1000V:5VTRANSDUCER 0-1000V:0-5VDC 0.5% |
2,395 |
|
Datasheet | DC1-PRO | Case | Active | DC Voltage Transducer | 0 ~ 1000VDC | 0 ~ 5VDC | 3000V, 1 minute | 10ms | 0.5% | 15 ~ 36VDC | DIN Rail, Wall Mount | Screw Terminal | -35°C ~ 100°C | - |
|
ISOBLOCK V-1C (5V 5V)VOLTAGE SEN W/GALVANIC ISOLATION |
3,589 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±5V | ±5V | 1500V (Working) | 3µs | ±0.2% | 12 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | CE |
|
|
2814731TRANSDUCER CURRENT 20-30VDC |
1,914 |
|
Datasheet | MCR | Bulk | Obsolete | Current Transducer | 0 ~ 11A | ±10VDC, 0 ~ 20mA | 300VAC (Working), 4000VAC (Test) | 40ms, 330ms | - | 20 ~ 30VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C | CE, cULus |
|
CPTDINAV53HA1AXTRANSDUCER VOLTAGE 90-260VAC/DC |
4,146 |
|
Datasheet | CPT-DIN | Bulk | Active | True RMS AC Voltage Transducer | 400 ~ 690VAC | 0 ~ 20mA | 4000VAC (Test) | 400ms | ±0.5% | 90 ~ 260VAC/DC | DIN Rail | Screw Terminal | 0°C ~ 50°C | CE, CSA, cURus |
Frequently Asked Questions
What are Current/Voltage Transducer Monitors components used for?
Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current/Voltage Transducer Monitors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.