Current/Voltage Transducer Monitors
Explore Current/Voltage Transducer Monitors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output | Isolation | Response Time | Accuracy | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
10CP552SINGLE PHASE CURRENT TRANSDUCER |
1,736 |
|
Datasheet | - | Bulk | Active | Current Transducer | 0 ~ 10A | 4 ~ 20mA | - | 400ms | ±0.2% | 100 ~ 130VAC | Chassis Mount | Screw Terminal | -20°C ~ 70°C | - |
|
DN-848VI-80V8-CH 80 VDC VOLTAGE ATTENUATOR |
4,732 |
|
Datasheet | DN-848VI | Box | Active | Voltage Transducer | ±80V | ±10V | 3000VAC (Test) | - | 1% | 10 ~ 24VDC | DIN Rail | - | -25°C ~ 75°C | CE, FCC |
|
P29001P2/01CURRENT TRANSDUCER 1000 VDC |
2,014 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±100V (Configurable) | ±20mA, ±10V (Configurable) | 1000VAC/DC (Working), 5400VAC (Test) | 200µs | ±0.1% | 20 ~ 230VAC/DC | DIN Rail | Screw Terminal | -25°C ~ 70°C | cULus |
|
P41000D1-S024CURRENT TRANSDUCER 2200 VDC |
2,455 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±300mV (Configurable) | ±2mA (Configurable) | 2200VAC/DC (Working), 10000VAC (Test) | 110µs | ±0.1% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | UL |
|
P41000D1-0121CURRENT TRANSDUCER 2200 VDC |
4,710 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±100mV (Configurable) | ±20mA, ±10V (Configurable) | 2200VAC/DC (Working), 10000VAC (Test) | 110µs | ±0.1% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | UL |
|
P41000D1CURRENT TRANSDUCER 2200 VDC |
3,187 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±10V (Configurable) | ±20mA, ±10V (Configurable) | 2200VAC/DC (Working), 10000VAC (Test) | 110µs | ±0.1% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | UL |
|
P41100D1-0028CURRENT TRANSDUCER 3600 VDC |
4,806 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±50mV | 4 ~ 20mA | 3600VAC/DC (Working), 15000VAC (Test) | 110µs | ±0.1% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | UL |
|
P42001D3VOLTAGE TRANSDUCER 2200 VDC |
1,469 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±2200V (Configurable) | ±20mA, ±10V (Configurable) | 2200VAC/DC (Working), 10000VAC (Test) | 110µs | ±0.3% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | UL |
|
P42000D3VOLTAGE TRANSDUCER 2200 VDC |
3,929 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±3600V (Configurable) | ±20mA, ±10V (Configurable) | 2200VAC/DC (Working), 10000VAC (Test) | 110µs | ±0.3% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | UL |
|
P42000D2VOLTAGE TRANSDUCER 2200 VDC |
1,762 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±1200V (Configurable) | ±20mA, ±10V (Configurable) | 2200VAC/DC (Working), 10000VAC (Test) | 110µs | ±0.3% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | UL |
|
P42000D3-S043VOLTAGE TRANSDUCER 2200 VDC |
2,235 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±2000V (Configurable) | ±2mA (Configurable) | 2200VAC/DC (Working), 10000VAC (Test) | 110µs | ±0.3% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | UL |
|
T201DCHTRMS Current Transducer, 50 AAC/ |
2,392 |
|
Datasheet | T201 | Bulk | Active | True RMS AC Voltage Transducer | 0 ~ 50VAC, 0 ~ 50VDC (Configurable) | 0 ~ 10VDC | 3000VAC | 800ms | 1% | 10 ~ 28VDC | DIN Rail | Spring Terminal | -10°C ~ 60°C | CE, UL |
|
DVT-1000-420TRANSDUCER 0-1000V:4-20MA 0.5% |
4,833 |
|
Datasheet | DVT | Tape & Box (TB) | Active | DC Voltage Transducer | 0 ~ 1000VDC | 4 ~ 20mA | 4500V (Test) | 200ms | 0.005% | 15 ~ 48VDC | DIN Rail | Screw Terminal | -30°C ~ 70°C | - |
|
10VP552SINGLE PHASE VOLTAGE TRANSDUCER |
2,024 |
|
Datasheet | - | Bulk | Active | Voltage Transducer | 0 ~ 180V | 4 ~ 20mA | - | 400ms | ±0.2% | 100 ~ 130VAC | Chassis Mount | Screw Terminal | -20°C ~ 70°C | - |
|
|
CR4550-500TRANSDUCER VOLTAGE 24VDC |
4,044 |
|
Datasheet | CR4500 | Bulk | Active | True RMS AC Voltage Transducer | 0 ~ 500VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
TPRVM001TESYS ISLAND VOLTAGE INTERFACE M |
4,445 |
|
Datasheet | - | Box | Active | DC Voltage Transducer | - | - | - | - | ±5% | 24VDC | DIN Rail | Spring Terminal | -10°C ~ 60°C | CSA, EAC, UL |
|
ISOBLOCK I-FG-1C (6A 5V)TRANSDUCER CURRENT 9-28VDC |
1,092 |
|
Datasheet | IsoBlock I-FG | Box | Active | Current Transducer | 0 ~ 6A | ±5V | 1200V (Working) | 5µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK I-FG-1C (15A 5V)TRANSDUCER CURRENT 9-28VDC |
3,126 |
|
Datasheet | IsoBlock I-FG | Box | Active | Current Transducer | 0 ~ 15A | ±5V | 1200V (Working) | 5µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ENTUBE SE (100V 10V)TRANSDUCER VOLTAGE DIVIDER |
3,356 |
|
Datasheet | Entube SE | Box | Active | Voltage Transducer | ±100V | ±10V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ENTUBE SE (500V 5V)TRANSDUCER VOLTAGE DIVIDER |
2,401 |
|
Datasheet | Entube SE | Box | Active | Voltage Transducer | ±500V | ±5V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
Frequently Asked Questions
What are Current/Voltage Transducer Monitors components used for?
Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current/Voltage Transducer Monitors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.