Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Input Range Output Isolation Response Time Accuracy Voltage - Supply Mounting Type Termination Style Operating Temperature Approval Agency
ATR-5A-04 Aim Dynamics

ATR-5A-04

TRANSDUCER 3PH 60000A:5A 4"COIL

Aim Dynamics

3,500
Datasheet ATR Tape & Box (TB) Active AC Current Transducer 2.5 ~ 60000A 5A - 10ms 0.01% 24VDC Chassis Mount, DIN Rail Screw Terminal - CE, UL
ATR-5A-07 Aim Dynamics

ATR-5A-07

TRANSDUCER 3PH 60000A:5A 7"COIL

Aim Dynamics

1,205
Datasheet ATR Tape & Box (TB) Active AC Current Transducer 2.5 ~ 60000A 5A - 10ms 0.01% 24VDC Chassis Mount, DIN Rail Screw Terminal - CE, UL
ATR-5A-11 Aim Dynamics

ATR-5A-11

TRANSDUCER 3PH 60000A:5A 11"COIL

Aim Dynamics

3,369
Datasheet ATR Tape & Box (TB) Active AC Current Transducer 2.5 ~ 60000A 5A - 10ms 0.01% 24VDC Chassis Mount, DIN Rail Screw Terminal - CE, UL
CR4510-250 CR Magnetics Inc.

CR4510-250

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

3,551
Datasheet CR4500 Box Active True RMS AC Voltage Transducer 0 ~ 250VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4510-500 CR Magnetics Inc.

CR4510-500

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

4,940
Datasheet CR4500 Box Active True RMS AC Voltage Transducer 0 ~ 500VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
ISOBLOCK I-FG-1C (6A 10V) Verivolt LLC

ISOBLOCK I-FG-1C (6A 10V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

4,752
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 6A ±10V 1200V (Working) 5µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK I-FG-1C (50A 10V) Verivolt LLC

ISOBLOCK I-FG-1C (50A 10V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

3,403
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 50A ±10V 1200V (Working) 5µs ±0.2% 9 ~ 28VDC DIN Rail Screw Terminal, Spring Terminal -25°C ~ 70°C -
2308108 Phoenix Contact

2308108

TRANSDUCER CURRENT 24VDC

Phoenix Contact

3,079
Datasheet MCR Bulk Active Current Transducer 0 ~ 100A 0 ~ 10VDC 300VAC (Working), 3500VAC (Test) 150ms - 24VDC Chassis Mount, DIN Rail Spring Terminal -40°C ~ 65°C CE, cULus
2308027 Phoenix Contact

2308027

TRANSDUCER CURRENT 24VDC

Phoenix Contact

4,588
Datasheet MCR Bulk Active Current Transducer 0 ~ 100A 4 ~ 20mA 300VAC (Working), 3500VAC (Test) 150ms - 24VDC Chassis Mount, DIN Rail Spring Terminal -40°C ~ 65°C CE, cULus
2308030 Phoenix Contact

2308030

TRANSDUCER CURRENT 24VDC

Phoenix Contact

1,580
Datasheet MCR Bulk Active Current Transducer 0 ~ 200A 4 ~ 20mA 300VAC (Working), 3500VAC (Test) 150ms - 24VDC Chassis Mount, DIN Rail Spring Terminal -40°C ~ 65°C CE, cULus
ISOBLOCK V-1C (50V 10V) Verivolt LLC

ISOBLOCK V-1C (50V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

4,445
Datasheet IsoBlock V Box Active Voltage Transducer ±50V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-1C (300V 10V) Verivolt LLC

ISOBLOCK V-1C (300V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

2,612
Datasheet IsoBlock V Box Active Voltage Transducer ±300V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-1C (750V 10V) Verivolt LLC

ISOBLOCK V-1C (750V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

2,484
Datasheet IsoBlock V Box Active Voltage Transducer ±750V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-1C (100V 10V) Verivolt LLC

ISOBLOCK V-1C (100V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

1,857
Datasheet IsoBlock V Box Active Voltage Transducer ±100V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-1C (500V 10V) Verivolt LLC

ISOBLOCK V-1C (500V 10V)

TRANSDUCER VOLTAGE 8-28VDC

Verivolt LLC

4,966
Datasheet IsoBlock V Box Active Voltage Transducer ±500V ±10V 1500V (Working) 2.8µs ±0.2% 8 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
2906242 Phoenix Contact

2906242

TRANSDUCER VOLTAGE 24VDC

Phoenix Contact

1,855
Datasheet MACX Bulk Active Voltage Transducer ±660VDC ±10V 5300VAC (Test) 16ms - 24VDC DIN Rail Screw Terminal -25°C ~ 60°C CE, cULus
ISOBLOCK I-FG-4C (6A 10V) Verivolt LLC

ISOBLOCK I-FG-4C (6A 10V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

1,747
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 6A ±10V 1200V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK I-FG-4C (25A 10V) Verivolt LLC

ISOBLOCK I-FG-4C (25A 10V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

3,422
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 25A ±10V 1200V (Working) 5µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK I-FG-4C (15A 10V) Verivolt LLC

ISOBLOCK I-FG-4C (15A 10V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

2,801
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 15A ±10V 1200V (Working) 5µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK V-4C (1000V 10V) Verivolt LLC

ISOBLOCK V-4C (1000V 10V)

TRANSDUCER VOLTAGE 9-28VDC

Verivolt LLC

4,671
Datasheet IsoBlock V Box Active Voltage Transducer ±1000V ±10V 1500V (Working) 2.8µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
Total 1041 Record«Prev12345...53Next»
FAQ

Frequently Asked Questions

What are Current/Voltage Transducer Monitors components used for?

Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current/Voltage Transducer Monitors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Current/Voltage Transducer Monitors?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top