Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Input Range Output Isolation Response Time Accuracy Voltage - Supply Mounting Type Termination Style Operating Temperature Approval Agency
ENTUBE QE (1500V 5V L-N ) Verivolt LLC

ENTUBE QE (1500V 5V L-N )

THREE-PHASE VOLT DIVIDER W/NEUT

Verivolt LLC

3,582
Datasheet Entube QE Box Active Voltage Transducer ±1500V ±5V - - ±0.2% - DIN Rail RJ45, Spring Terminal -25°C ~ 70°C CE
ENTUBE QE (500VAC 7VAC L-N ) Verivolt LLC

ENTUBE QE (500VAC 7VAC L-N )

THREE-PHASE VOLT DIVIDER W/NEUT

Verivolt LLC

1,132
Datasheet Entube QE Box Active Voltage Transducer 0 ~ 500VAC 0 ~ 7VAC - - ±0.2% - DIN Rail RJ45, Spring Terminal -25°C ~ 70°C CE
ENTUBE QE (250VAC 7VAC L-L ) Verivolt LLC

ENTUBE QE (250VAC 7VAC L-L )

THREE-PHASE VOLT DIVIDER W/NEUT

Verivolt LLC

1,915
Datasheet Entube QE Box Active Voltage Transducer 0 ~ 250VAC 0 ~ 7VAC - - ±0.2% - DIN Rail RJ45, Spring Terminal -25°C ~ 70°C CE
ENTUBE QE (250VAC 7VAC L-N ) Verivolt LLC

ENTUBE QE (250VAC 7VAC L-N )

THREE-PHASE VOLT DIVIDER W/NEUT

Verivolt LLC

1,179
Datasheet Entube QE Box Active Voltage Transducer 0 ~ 250VAC 0 ~ 7VAC - - ±0.2% - DIN Rail RJ45, Spring Terminal -25°C ~ 70°C CE
ENTUBE QE (500VAC 7VAC L-L ) Verivolt LLC

ENTUBE QE (500VAC 7VAC L-L )

THREE-PHASE VOLT DIVIDER W/NEUT

Verivolt LLC

3,149
Datasheet Entube QE Box Active Voltage Transducer 0 ~ 500VAC 0 ~ 7VAC - - ±0.2% - DIN Rail RJ45, Spring Terminal -25°C ~ 70°C CE
CR4860-500 CR Magnetics Inc.

CR4860-500

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

3,210
Datasheet CR4800 Bulk Active Average RMS AC Voltage Transducer 0 ~ 500VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4860-50 CR Magnetics Inc.

CR4860-50

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

1,603
Datasheet CR4800 Bulk Active Average RMS AC Voltage Transducer 0 ~ 50VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4860-150 CR Magnetics Inc.

CR4860-150

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

1,385
Datasheet CR4800 Bulk Active Average RMS AC Voltage Transducer 0 ~ 150VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4860-250 CR Magnetics Inc.

CR4860-250

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

1,119
Datasheet CR4800 Bulk Active Average RMS AC Voltage Transducer 0 ~ 250VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4520-150 CR Magnetics Inc.

CR4520-150

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

4,439
Datasheet CR4500 Box Active True RMS AC Voltage Transducer 0 ~ 150VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4520-250 CR Magnetics Inc.

CR4520-250

TRANSDUCER VOLTAGE 250V TRUE RMS

CR Magnetics Inc.

1,840
Datasheet CR4500 Bulk Active True RMS AC Voltage Transducer 0 ~ 250VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4520-50 CR Magnetics Inc.

CR4520-50

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

2,884
Datasheet CR4500 Bulk Active True RMS AC Voltage Transducer 0 ~ 50VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
T201DC100 Seneca

T201DC100

Loop Power DC Current Transducer

Seneca

4,264
Datasheet T201 Bulk Active DC Current Transducer 0 ~ 100VAC (Configurable) 4 ~ 20mA 3000VAC 100ms ±0.2% 6 ~ 100V DIN Rail Spring Terminal -10°C ~ 60°C CE, UL
CR6220-150-5 CR Magnetics Inc.

CR6220-150-5

TRANSDUCER AC 4-20MA OUT 1 PHASE

CR Magnetics Inc.

3,898
Datasheet CR6200 Box Active Current Transducer 0 ~ 150VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus, UL
CR6220-250-5 CR Magnetics Inc.

CR6220-250-5

TRANSDCR AC 4-20 MADC OUT 1PHASE

CR Magnetics Inc.

1,840
Datasheet CR6200 Bulk Active Current Transducer 0 ~ 250VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus, UL
CR4870-500 CR Magnetics Inc.

CR4870-500

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

4,505
Datasheet CR4800 Bulk Active Average RMS AC Voltage Transducer 0 ~ 500VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4870-50 CR Magnetics Inc.

CR4870-50

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

4,008
Datasheet CR4800 Bulk Active Average RMS AC Voltage Transducer 0 ~ 50VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4870-250 CR Magnetics Inc.

CR4870-250

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

1,525
Datasheet CR4800 Bulk Active Average RMS AC Voltage Transducer 0 ~ 250VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR4870-150 CR Magnetics Inc.

CR4870-150

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

2,599
Datasheet CR4800 Bulk Active Average RMS AC Voltage Transducer 0 ~ 150VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
CR6220-150-20 CR Magnetics Inc.

CR6220-150-20

TRANSDCR AC 4-20 MADC OUT 1PHASE

CR Magnetics Inc.

3,422
Datasheet CR6200 Bulk Active Current Transducer 0 ~ 150VAC 4 ~ 20mA 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus, UL
Total 1041 Record«Prev1... 678910111213...53Next»
FAQ

Frequently Asked Questions

What are Current/Voltage Transducer Monitors components used for?

Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current/Voltage Transducer Monitors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.