ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Signal Conditioners and Isolators

Explore Signal Conditioners and Isolators parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Input Type Input Range (Current, Voltage) Input Range (Additional) Output Type Output Range Isolation Features Voltage - Supply Mounting Type Termination Style Operating Temperature
1175980000 Weidmüller

1175980000

SIGNAL CONVERTER/DISCONNECTOR

Weidmüller

2,789
Datasheet ACT20M Bulk Active Isolation Amplifier Current 4 ~ 20mA - Current 4 ~ 20mA 300V (Working), 2500V (Test) - 24VDC DIN Rail Screw Terminal -25°C ~ 70°C
2902016 Phoenix Contact

2902016

MINI MCR-2-POT-UI

Phoenix Contact

3,862
Datasheet MINI MCR Bulk Active Signal Conditioner Resistance - 0.1 ~ 100kOhm Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) - - 24VDC DIN Rail Screw Terminal -40°C ~ 70°C
857-416 WAGO Corporation

857-416

ISOLATION AMPLIFIER; CURRENT INP

WAGO Corporation

4,429
Datasheet 857 Bag Active Isolation Amplifier Current 4 ~ 20mA 0 ~ 50Ohm Voltage 0 ~ 10V 2500V (Test) - 24VDC DIN Rail Spring Terminal -25°C ~ 70°C
1175990000 Weidmüller

1175990000

SIGNAL CONVERTER/DISCONNECTOR

Weidmüller

1,558
Datasheet ACT20M Bulk Active Isolation Amplifier Current 0 ~ 20mA - Current 0 ~ 20mA 300V (Working), 2500V (Test) - 24VDC DIN Rail Screw Terminal -25°C ~ 70°C
8965430000 Weidmüller

8965430000

SIGNAL CONVERTER/DISCONNECTOR

Weidmüller

1,505
Datasheet ACT20X Bulk Active Isolation Amplifier Current 4 ~ 20mA 0.5 ~ 2.5kHz Current 4 ~ 20mA 300V (Working), 2600V (Test) Alarm Relay (2) 19.2 ~ 31.2VDC DIN Rail Screw Terminal -20°C ~ 60°C
1477420000 Weidmüller

1477420000

ACT20P-AI-AO-DC-S

Weidmüller

1,850
Datasheet ACT20P Bulk Active Signal Conditioner Current, Voltage 0 ~ 22mA, 0 ~ 11V (Configurable) - Current 0 ~ 22mA 2000V (Test) - 12 ~ 60VDC DIN Rail Screw Terminal -20°C ~ 60°C
2865007 Phoenix Contact

2865007

3-WAY ISOLATING AMP 4-20MA

Phoenix Contact

3,734
Datasheet MINI MCR Bulk Active Signal Conditioner Voltage 0 ~ 30V (Configurable) - Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) 1500V (Test) - 24VDC DIN Rail Screw Terminal -20°C ~ 65°C
2865421 Phoenix Contact

2865421

SET CONSISTING OF A 1 A MEASURIN

Phoenix Contact

1,453
Datasheet MACX MCR Box Active Signal Conditioner Current 0 ~ 24mA - Current 0 ~ 24mA 375V - 24VDC DIN Rail Screw Terminal -40°C ~ 70°C
8965440000 Weidmüller

8965440000

SIGNAL CONVERTER/DISCONNECTOR

Weidmüller

4,123
Datasheet ACT20X Bulk Active Signal Conditioner Current 4 ~ 20mA (Configurable) - Current 4 ~ 20mA (Configurable) 300V (Working), 2600V (Test) - 19.2 ~ 31.2VDC DIN Rail Screw Terminal -20°C ~ 60°C
RMA42-AAA Endress+Hauser

RMA42-AAA

TRANSMITTER 1X UNIVERSAL 1X ANAL

Endress+Hauser

4,414
Datasheet RMA42 Box Active Signal Conditioner Current, Resistance, Voltage 0 ~ 20mA, ±100mV (Configurable) 0.03 ~ 3kOhm Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) 500V - 24VDC DIN Rail Screw Terminal -20°C ~ 60°C
8965490000 Weidmüller

8965490000

SIGNAL CONVERTER/DISCONNECTOR

Weidmüller

4,701
Datasheet ACT20X Bulk Active Signal Conditioner Current, Voltage, Resistance, Temperature 0 ~ 20mA, 0 ~ 10V 0 ~ 100kOhm, -200°C ~ 800°C Current 0 ~ 23mA 300V (Working), 2600V (Test) Alarm Relay (2) 19.2 ~ 31.2VDC DIN Rail Screw Terminal -20°C ~ 60°C
1481960000 Weidmüller

1481960000

SIGNAL CONDITIONER ACT20P

Weidmüller

1,897
Datasheet ACT20P Bulk Active Signal Conditioner Current, Voltage ±100mA, ±300V (Configurable) - Current, Voltage ±20mA, ±10V (Configurable) 600V (Working), 4000V (Test) - 24 ~ 230VAC/DC DIN Rail Spring Terminal -
2811569 Phoenix Contact

2811569

ISOLATED AMP

Phoenix Contact

1,263
Datasheet MACX MCR Bulk Active Signal Conditioner Current, Voltage ±100mA, ±100V (Configurable) - Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) - - 24 ~ 230VAC/DC DIN Rail Spring Terminal -20°C ~ 70°C
RNO22-AA1B Endress+Hauser

RNO22-AA1B

OUTPUT AMPLIFIER 1-CHANNEL

Endress+Hauser

3,212
Datasheet RNO22 Box Active Isolation Amplifier Current 0 ~ 20mA (Configurable) - Current 0 ~ 20mA (Configurable) 2500VAC (Test) - 24V DIN Rail Screw Terminal -40°C ~ 70°C
RNO22-8M1A Endress+Hauser

RNO22-8M1A

OUTPUT AMPLIFIER ATEX 1-CHANNEL

Endress+Hauser

3,274
Datasheet RNO22 Box Active Isolation Amplifier Current 0 ~ 20mA (Configurable) - Current 0 ~ 20mA (Configurable) 2500VAC (Test) - 24V DIN Rail Screw Terminal -40°C ~ 70°C
RN22-CB2B+LT Endress+Hauser

RN22-CB2B+LT

ACTIVE BARRIER CSA 2-CHANNEL PUS

Endress+Hauser

1,732
Datasheet RN22 Box Active Signal Conditioner Current 0 ~ 20mA (Configurable) - Current 0 ~ 20mA (Configurable) 3000VAC (Test) - 24V DIN Rail Screw Terminal -40°C ~ 60°C
RN22-8L2B Endress+Hauser

RN22-8L2B

ACTIVE BARRIER ATEX 2-CHANNEL

Endress+Hauser

1,840
Datasheet RN22 Box Active Signal Conditioner Current 0 ~ 20mA (Configurable) - Current 0 ~ 20mA (Configurable) 3000VAC (Test) - 24V DIN Rail Screw Terminal -40°C ~ 60°C
2908065 Phoenix Contact

2908065

2-CHANNEL OUTPUT SIGNAL CONDITIO

Phoenix Contact

4,127
Datasheet MACX MCR Box Active Signal Conditioner Current 0 ~ 24mA - Current 0 ~ 24mA - - 24VDC DIN Rail Screw Terminal -40°C ~ 70°C
2908066 Phoenix Contact

2908066

2-CHANNEL OUTPUT SIGNAL CONDITIO

Phoenix Contact

1,943
Datasheet MACX MCR Box Active Signal Conditioner Current 0 ~ 24mA - Current 0 ~ 24mA - - 24VDC DIN Rail Screw Terminal -40°C ~ 70°C
1282490000 Weidmüller

1282490000

ACT20M-FEED-IN-BASIC-S

Weidmüller

4,337
Datasheet - Bulk Active Signal Conditioner Current, Voltage 0.5 ~ 2.5A, 21.6 ~ 26.4VDC - Current, Voltage 0.5 ~ 2.5A, 21.6 ~ 26.4VDC - - 21.6 ~ 26.4VDC DIN Rail Screw Terminal -25°C ~ 70°C
Total 1063 Record«Prev1... 3132333435363738...54Next»
FAQ

Frequently Asked Questions

What are Signal Conditioners and Isolators components used for?

Signal Conditioners and Isolators components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Signal Conditioners and Isolators part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Signal Conditioners and Isolators parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Signal Conditioners and Isolators?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top