Signal Conditioners and Isolators
Explore Signal Conditioners and Isolators parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Type | Input Range (Current, Voltage) | Input Range (Additional) | Output Type | Output Range | Isolation | Features | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CTX-AC-0AC Current Transmitter, Split Co |
4,113 |
|
Datasheet | CTX-AC | Bulk | Active | Transmitter Isolator | Current | 0 ~ 5A (Configurable) | - | Current | 4 ~ 20mA | 1270VAC, 5000VAC (Test) | - | Loop Powered | Chassis Mount | - | -20°C ~ 50°C |
|
K109TCTC to DC Isolated Transmitter |
1,245 |
|
Datasheet | K-Line | Bulk | Active | Transmitter Isolator | Temperature | - | -210°C ~ 1820°C (Configurable) | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 1500V | BUS Power Option, SPST Relay | 19.2 ~ 30VDC | DIN Rail | Spring Terminal | -20°C ~ 65°C |
|
K109PTRTD to DC Isolated Transmitter, |
1,011 |
|
Datasheet | K-Line | Bulk | Active | Transmitter Isolator | Resistance, Temperature | - | 100Ohm, -210°C ~ 2320°C | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 1500V | BUS Power Option | 19.2 ~ 30VDC | DIN Rail | Spring Terminal | -20°C ~ 65°C |
|
CTX-AC-3SAC Current Transmitter, Solid Co |
3,719 |
|
Datasheet | CTX-AC | Bulk | Active | Transmitter Isolator | Current | 0 ~ 750A (Configurable) | - | Current | 4 ~ 20mA | 3000VAC | - | Loop Powered | Chassis Mount | - | -20°C ~ 50°C |
|
3B32-003B32 - ISO MA INPUT - REQUIRES A |
2,560 |
|
Datasheet | * | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - |
|
CN-6100-C2Signal Conditioner Universal Inp |
1,900 |
|
Datasheet | CN-6000 | Retail Package | Active | Signal Conditioner | Current, Voltage, Resistance, Temperature | 0 ~ 20mA, -1 ~ 10V | -200°C ~ 2300°C (Configurable) | Current | 0 ~ 20mA | - | - | 100 ~ 240VAC | Panel Mount | 11-Pin Socket | -10°C ~ 50°C |
|
CN-6401-V1Signal Conditioner Pulse input |
3,836 |
|
Datasheet | CN-6000 | Retail Package | Active | Signal Conditioner | Pulse | 0 ~ 50.00kHz | -200°C ~ 2300°C (Configurable) | Voltage | 0 ~ 10V | - | - | 24VDC | Panel Mount | 8-Pin Socket | -10°C ~ 50°C |
|
CN-6101-C1Signal Conditioner Universal Inp |
4,863 |
|
Datasheet | CN-6000 | Retail Package | Active | Signal Conditioner | Current, Voltage, Resistance, Temperature | 0 ~ 20mA, -1 ~ 10V | -200°C ~ 2300°C (Configurable) | Current | 0 ~ 20mA | - | - | 24VDC | Panel Mount | 8-Pin Socket | -10°C ~ 50°C |
|
CN-6101-V2Signal Conditioner Universal Inp |
1,150 |
|
Datasheet | CN-6000 | Retail Package | Active | Signal Conditioner | Current, Voltage, Resistance, Temperature | 0 ~ 20mA, -1 ~ 10V | -200°C ~ 2300°C (Configurable) | Voltage | 0 ~ 10V | - | - | 24VDC | Panel Mount | 11-Pin Socket | -10°C ~ 50°C |
|
CN-6101-C2Signal Conditioner Universal Inp |
2,716 |
|
Datasheet | CN-6000 | Retail Package | Active | Signal Conditioner | Current, Voltage, Resistance, Temperature | 0 ~ 20mA, -1 ~ 10V | -200°C ~ 2300°C (Configurable) | Current | 0 ~ 20mA | - | - | 24VDC | Panel Mount | 11-Pin Socket | -10°C ~ 50°C |
|
3B43-003B43 - ISO AC SINE INPUT - REQUI |
4,318 |
|
Datasheet | * | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - |
|
CTX-AC-4SAC Current Transmitter, Solid Co |
4,646 |
|
Datasheet | CTX-AC | Bulk | Active | Transmitter Isolator | Current | 0 ~ 2000A (Configurable) | - | Current | 4 ~ 20mA | 3000VAC | - | Loop Powered | Chassis Mount | - | -20°C ~ 50°C |
|
APD 4300 D4-20mA DC to DC Transmitter |
4,848 |
|
Datasheet | APD | Bulk | Active | Signal Conditioner | Current | 4 ~ 20mA | - | Current | 4 ~ 20mA | 1200V | Input Loop Supply, LoopTracker LEDs, Output Test Button | 10 ~ 32VAC, 9 ~ 30VDC | DIN Rail | Screw Terminal | -10°C ~ 60°C |
|
APD 4008 DPotentiometer Transmitter |
3,090 |
|
Datasheet | APD | Bulk | Active | Signal Conditioner | Resistance | - | 100 ~ 1MOhm | Current, Voltage | 0 ~ 20mA, 0 ~ 10V, ±10V (Configurable) | 1200V | LoopTracker LEDs, Output Test Button | 10 ~ 32VAC, 9 ~ 30VDC | DIN Rail | Screw Terminal | -10°C ~ 60°C |
|
APD 43004-20mA DC to DC Transmitter |
3,906 |
|
Datasheet | APD | Bulk | Active | Signal Conditioner | Current | 4 ~ 20mA | - | Current | 4 ~ 20mA | 1200V | Input Loop Supply, LoopTracker LEDs, Output Test Button | 85 ~ 265VAC, 60 ~ 300VDC | DIN Rail | Screw Terminal | -10°C ~ 60°C |
|
API 4008 G DPotentiometer Transmitter |
1,263 |
|
Datasheet | API | Bulk | Active | Signal Conditioner | Resistance | - | 100 ~ 1MOhm | Current, Voltage | 0 ~ 20mA, 0 ~ 10V, ±10V (Configurable) | 2000V | Excitation Supply, LoopTracker LEDs, Output Test Button | 9 ~ 30VDC | - | Screw Terminal | -10°C ~ 60°C |
|
APD 7500 DDC to Frequency Transmitter |
1,597 |
|
Datasheet | APD | Bulk | Active | Signal Conditioner | Current, Voltage | 0 ~ 20mA, ±10V (Configurable) | - | Frequency | 0 ~ 1500 Hz, 0 ~ 30 kHz (Configurable) | 1200V | LoopTracker LEDs, Output Test Button | 10 ~ 32VAC, 9 ~ 30VDC | DIN Rail | Screw Terminal | -10°C ~ 60°C |
|
APD 7580Frequency to DC Transmitter |
3,196 |
|
Datasheet | APD | Bulk | Active | Signal Conditioner | Frequency | 0 ~ 100Hz, 0 ~ 30kHz (Configurable) | - | Current, Voltage | 0 ~ 20mA, 0 ~ 10V, ±10V (Configurable) | 1200V | LoopTracker LEDs, Output Test Button | 85 ~ 265VAC, 60 ~ 300VDC | DIN Rail | Screw Terminal | -10°C ~ 60°C |
|
CTX-ACR-4SAC Current Transmitter, Solid Co |
2,549 |
|
Datasheet | CTX-AC | Bulk | Active | Transmitter Isolator | Current | 0 ~ 2000A (Configurable) | - | Current | 4 ~ 20mA | 3000VAC | True RMS | Loop Powered | Chassis Mount | - | -20°C ~ 50°C |
|
API 7500 GDC to Frequency Transmitter |
2,188 |
|
Datasheet | API | Bulk | Active | Signal Conditioner | Current, Voltage | 0 ~ 20mA, ±10V (Configurable) | - | Frequency | 0 ~ 1500 Hz, 0 ~ 30 kHz (Configurable) | 2000V | LoopTracker LEDs, Output Test Button | 115VAC | - | Screw Terminal | -10°C ~ 60°C |
Frequently Asked Questions
What are Signal Conditioners and Isolators components used for?
Signal Conditioners and Isolators components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Signal Conditioners and Isolators part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Signal Conditioners and Isolators parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.