Signal Conditioners and Isolators
Explore Signal Conditioners and Isolators parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Type | Input Range (Current, Voltage) | Input Range (Additional) | Output Type | Output Range | Isolation | Features | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ADAM-3014-AEISOLATED DC I/O MODULE |
3,099 |
|
Datasheet | ADAM-3014 | Box | Active | Isolation Amplifier | Current, Voltage | ±20mA, ±10V (Configurable) | - | Current, Voltage | 0 ~ 20mA, ±10V | 1000V | - | 24VDC | DIN Rail | Screw Terminal | -10°C ~ 70°C |
|
2901994SINGLE-CHANNEL INPUT LOOP-POWERE |
3,393 |
|
Datasheet | MINI MCR | Bulk | Active | Isolation Amplifier | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | 3000V (Test) | - | Loop Powered | DIN Rail | Screw Terminal | -40°C ~ 70°C |
|
|
2901998MINI MCR-2-I-I |
3,861 |
|
Datasheet | MINI MCR | Bulk | Active | Isolation Amplifier | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | - | - | 24VDC | DIN Rail | Screw Terminal | -40°C ~ 70°C |
|
7760054122SIGNAL DISTRIBUTOR SCREW CONN |
3,907 |
|
Datasheet | ACT20P | Bulk | Active | Signal Conditioner | Current | 4 ~ 20mA | - | Current | 4 ~ 20mA | 300V (Working), 2000V (Test) | - | Loop Powered | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
|
2902061OUTPUT LOOP-POWERED 2-WAY ISOLAT |
2,058 |
|
Datasheet | MINI MCR | Bulk | Active | Signal Conditioner | Current | 4 ~ 20mA, ±20V (Configurable) | - | Current | 4 ~ 20mA (Configurable) | 3000V (Test) | - | Loop Powered | DIN Rail | - | -25°C ~ 65°C |
|
2902019MINI MCR-2-U-UI |
1,364 |
|
Datasheet | MINI MCR | Bulk | Active | Signal Conditioner | Voltage | 0 ~ 10V | - | Voltage | ±10V | 3000V | - | 24V | DIN Rail | Screw Terminal | -40°C ~ 70°C |
|
|
2902037MINI MCR-2-UI-UI |
111 |
|
Datasheet | MINI MCR | Bulk | Active | Signal Conditioner | Current, Voltage | ±20mA, ±30V (Configurable) | - | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | - | - | 24VDC | DIN Rail | Screw Terminal | -40°C ~ 70°C |
|
2864406MCR 3-WAY ISOLATING AMPLIFIER |
4,451 |
|
Datasheet | MINI MCR | Bulk | Active | Isolation Amplifier | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | 1500V (Test) | - | 24VDC | DIN Rail | Screw Terminal | -20°C ~ 65°C |
|
2905026UNIVERSALLY CONFIGURABLE 4-WAY S |
242 |
|
Datasheet | MINI MCR | Bulk | Active | Signal Conditioner | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | - | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 3000V (Test) | - | 24VDC | DIN Rail | Screw Terminal | -40°C ~ 70°C |
|
2902829REPEATER POWER SUPPLY |
4,578 |
|
Datasheet | MINI MCR | Bulk | Active | Signal Conditioner | Current | ±40mA, ±30V (Configurable) | - | Current | 4 ~ 20mA (Configurable) | 1500V (Test) | - | Loop Powered | DIN Rail | Screw Terminal | -25°C ~ 70°C |
|
857-800TEMPERATURE SIGNAL CONDITIONER F |
1,360 |
|
Datasheet | - | Bulk | Active | Signal Conditioner | Current, Voltage | - | - | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 2500V | - | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C |
|
|
28641764-WAY SIGNAL DUPLICATOR |
2,529 |
|
Datasheet | MINI MCR | Bulk | Active | Signal Conditioner Multiplier | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 1500V (Test) | - | 24VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
857-400ISOLATION AMPLIFIER; CURRENT AND |
2,391 |
|
Datasheet | - | Bulk | Active | Isolation Amplifier | Current, Voltage | - | - | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 2500V | - | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C |
|
2902014MINI MCR-2-RPSS-I-I |
4,987 |
|
Datasheet | MINI MCR | Bulk | Active | Isolation Amplifier | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | - | - | 24VDC | DIN Rail | Screw Terminal | -40°C ~ 70°C |
|
F11-40THERMOCOUPLE/RTD HEAD MOUNT ISOL |
3,641 |
|
Datasheet | - | Tape & Box (TB) | Active | - | - | - | - | - | - | - | - | - | DIN Rail | - | - |
|
ASI4511454-20mA Signal Splitter, 1 Input |
135 |
|
Datasheet | - | Retail Package | Active | Signal Conditioner | Current, Voltage | 0 ~ 20mA, 17.5 ~ 25V (Configurable) | - | Current | 0 ~ 20mA x 2 | 1500V | - | 20 ~ 30VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
ASI4511304-20mA Signal Isolator, 2 Channe |
4,325 |
|
Datasheet | - | Retail Package | Active | Signal Conditioner | Current | 4 ~ 20mA | - | Current | 4 ~ 20mA | 1500V | - | 20 ~ 30VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
ASI4511244-20mA Signal Splitter, 1 Input, |
200 |
|
Datasheet | - | Retail Package | Active | Signal Conditioner | Current | 4 ~ 20mA | - | Current | 4 ~ 20mA x 2 | 1000V | - | 24V | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
SEM1600TPt100 or thermocouple signal con |
3,780 |
|
Datasheet | - | Box | Active | Signal Conditioner | Resistance, Temperature, Voltage | -100 ~ 200mV | 0.01 ~ 10.5kOhm, -200°C ~ 1760°C | Current, Voltage | 0 ~ 20mA, ±10V | - | - | 10 ~ 32VAC, 10 ~ 48VDC | DIN Rail | Screw Terminal | -30°C ~ 70°C |
|
SEM1600VImA / voltage repeater conditione |
3,645 |
|
Datasheet | - | Box | Active | Signal Conditioner | Current, Voltage | ±50mA, ±50V | - | Current, Voltage | 0 ~ 20mA, ±10V | - | Loop Powered | 10 ~ 32VAC, 10 ~ 48VDC | DIN Rail | Screw Terminal | -30°C ~ 70°C |
Frequently Asked Questions
What are Signal Conditioners and Isolators components used for?
Signal Conditioners and Isolators components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Signal Conditioners and Isolators part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Signal Conditioners and Isolators parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.