Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Input Type Input Range (Current, Voltage) Input Range (Additional) Output Type Output Range Isolation Features Voltage - Supply Mounting Type Termination Style Operating Temperature
857-550 WAGO Corporation

857-550

CURRENT SIGNAL CONDITIONER; CURR

WAGO Corporation

3,378
Datasheet 857 Bag Active Signal Conditioner Current 0 ~ 5A (Configurable) 16 ~ 400Kz, 0 ~ 47mOhm Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) 2500V (Test) - 24VDC DIN Rail Spring Terminal -25°C ~ 70°C
2864150 Phoenix Contact

2864150

3-WAY ISOLATING AMP 4-20MA

Phoenix Contact

3,166
Datasheet MINI MCR Bulk Active Signal Conditioner Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) - Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) 1500V (Test) - 24VDC DIN Rail Screw Terminal -20°C ~ 65°C
PR100250 Kunbus GmbH

PR100250

REVPI AIO

Kunbus GmbH

3,679
Datasheet - Retail Package Active Signal Conditioner Current, Voltage, Temperature ±25mA, ±10V -200°C ~ 850°C Current, Voltage 0 ~ 24mA, ±11V - - 12 ~ 24VDC DIN Rail Spring Terminal -30°C ~ 55°C
857-401 WAGO Corporation

857-401

ISOLATION AMPLIFIER; CURRENT AND

WAGO Corporation

1,754
Datasheet 857 Bag Active Isolation Amplifier Current, Voltage ±20mA, 0 ~ 30V (Configurable) 0 ~ 100kOhm Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) 2500V (Test) - 24VDC DIN Rail Spring Terminal -25°C ~ 70°C
2905280 Phoenix Contact

2905280

TWO-CHANNEL 2-WAY ISOLATOR

Phoenix Contact

4,335
Datasheet MACX MCR Bulk Active Passive Isolator Current 0 ~ 20mA - Current 0 ~ 20mA - - Loop Powered DIN Rail Screw Terminal -40°C ~ 85°C
857-409 WAGO Corporation

857-409

ISOLATION AMPLIFIER; BIPOLAR CUR

WAGO Corporation

4,275
Datasheet 857 Bag Active Isolation Amplifier Current, Voltage ±20mA, ±10V (Configurable) 0 ~ 1MOhm Current, Voltage ±20mA, ±10V (Configurable) 3000V (Test) - 24VDC DIN Rail Spring Terminal -25°C ~ 70°C
2865382 Phoenix Contact

2865382

TRANSDUCER MEASURING 0/4-20MA

Phoenix Contact

1,924
Datasheet MACX MCR Bulk Active Isolation Amplifier Current 0 ~ 20mA - Current 4 ~ 20mA 375V - 24VDC DIN Rail Screw Terminal -20°C ~ 60°C
2864655 Phoenix Contact

2864655

2 CHANNEL PASSIVE ISOLATOR

Phoenix Contact

1,114
Datasheet MINI MCR Bulk Active Passive Isolator Current 0 ~ 20mA - Current 0 ~ 20mA 1500V (Test) - Loop Powered DIN Rail Screw Terminal -20°C ~ 65°C
2906239 Phoenix Contact

2906239

MACX MCR VOLTAGE TRANSDUCER, FOR

Phoenix Contact

2,798
Datasheet MINI MCR Bulk Active Isolation Amplifier Voltage 0 ~ 660VAC 240 ~ 5500kOhm Current, Voltage 0 ~ 20mA, 0 ~ 10V 5300V (Test) - 24VDC DIN Rail Screw Terminal -25°C ~ 60°C
1481970000 Weidmüller

1481970000

ACT20P-PRO DCDC II-S

Weidmüller

3,804
Datasheet ACT20P Bulk Active Signal Conditioner Current, Voltage ±100mA, ±300V (Configurable) - Current, Voltage ±20mA, ±10V (Configurable) 600V (Working), 5000V (Test) - 24 ~ 230VAC/DC DIN Rail Screw Terminal -25°C ~ 70°C
2811446 Phoenix Contact

2811446

ISOLATED AMP DIN RAIL

Phoenix Contact

4,695
Datasheet MACX MCR Bulk Active Signal Conditioner Current, Voltage ±100mA, ±100V (Configurable) - Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) 2500V (Test) - 12 ~ 24VDC DIN Rail Spring Terminal -20°C ~ 70°C
2811556 Phoenix Contact

2811556

MCR 3-WAY ISOLATING AMPLIFIER

Phoenix Contact

2,517
Datasheet MACX MCR Bulk Active Isolation Amplifier Current, Voltage ±100mA, ±100V (Configurable) - Current, Voltage ±20mA, ±10V (Configurable) 2500V (Test) - 12 ~ 24VDC DIN Rail Spring Terminal -20°C ~ 70°C
857-423 WAGO Corporation

857-423

ISOLATION AMPLIFIER; CURRENT AND

WAGO Corporation

3,879
Datasheet - Bulk Active Isolation Amplifier Current, Voltage - - Current 0 ~ 20mA (Configurable) 2500V - 24VDC DIN Rail Spring Terminal -25°C ~ 70°C
2811297 Phoenix Contact

2811297

ISOLATED AMP 2 CHAN DIN RAIL

Phoenix Contact

4,258
Datasheet MACX MCR Bulk Active Signal Conditioner Current, Voltage ±100mA, ±100V (Configurable) - Current, Voltage ±20mA, ±10V (Configurable) 300V (Working) - 24 ~ 230VAC/DC DIN Rail Screw Terminal -20°C ~ 70°C
857-403 WAGO Corporation

857-403

ISOLATION AMPLIFIER UI UI (BIP)

WAGO Corporation

2,567
Datasheet 857 Bulk Active Isolation Amplifier Current, Voltage ±100mA, ±500V (Configurable) 0 ~ 1MOhm Current, Voltage ±20mA, ±10V (Configurable) 2500V (Test) - 24VDC DIN Rail Spring Terminal -25°C ~ 70°C
RMCN22BD Schneider Electric

RMCN22BD

HARMONY ANALOG, ISOLATED ANALOG

Schneider Electric

1,648
Datasheet Harmony Box Active Signal Conditioner Current, Voltage 4 ~ 20mA, 0 ~ 10V - Current, Voltage 4 ~ 20mA, 0 ~ 10V - - 24VDC DIN Rail Screw Terminal -40°C ~ 85°C
2901995 Phoenix Contact

2901995

SINGLE-CHANNEL INPUT LOOP-POWERE

Phoenix Contact

4,878
Datasheet MINI MCR Bulk Active Isolation Amplifier Current 0 ~ 20mA - Current 0 ~ 20mA 3000V (Test) - Loop Powered DIN Rail Spring Terminal -40°C ~ 70°C
2901999 Phoenix Contact

2901999

MINI MCR-2-I-I-PT

Phoenix Contact

3,817
Datasheet MINI MCR Bulk Active Isolation Amplifier Current 0 ~ 20mA - Current 0 ~ 20mA - - 24VDC DIN Rail Screw Terminal -40°C ~ 70°C
2902030 Phoenix Contact

2902030

MINI MCR-2-U-I4-PT

Phoenix Contact

2,802
Datasheet MINI MCR Bulk Active Signal Conditioner Voltage 0 ~ 10V - Current 4 ~ 20mA - - 24VDC DIN Rail Screw Terminal -40°C ~ 70°C
RMCV60BD Schneider Electric

RMCV60BD

HARMONY ANALOG, ISOLATED ANALOG

Schneider Electric

2,424
Datasheet Harmony Box Active Signal Conditioner Voltage 0 ~ 500V (Configurable) - Current, Voltage 0 ~ 20mA, 0 ~ 10V (Configurable) - - 24VDC DIN Rail Screw Terminal -40°C ~ 85°C
Total 1063 Record«Prev1234567...54Next»
FAQ

Frequently Asked Questions

What are Signal Conditioners and Isolators components used for?

Signal Conditioners and Isolators components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Signal Conditioners and Isolators part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Signal Conditioners and Isolators parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Signal Conditioners and Isolators?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top