Signal Conditioners and Isolators
Explore Signal Conditioners and Isolators parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Type | Input Range (Current, Voltage) | Input Range (Additional) | Output Type | Output Range | Isolation | Features | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
857-550CURRENT SIGNAL CONDITIONER; CURR |
3,378 |
|
Datasheet | 857 | Bag | Active | Signal Conditioner | Current | 0 ~ 5A (Configurable) | 16 ~ 400Kz, 0 ~ 47mOhm | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 2500V (Test) | - | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C |
|
|
28641503-WAY ISOLATING AMP 4-20MA |
3,166 |
|
Datasheet | MINI MCR | Bulk | Active | Signal Conditioner | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | - | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 1500V (Test) | - | 24VDC | DIN Rail | Screw Terminal | -20°C ~ 65°C |
|
PR100250REVPI AIO |
3,679 |
|
Datasheet | - | Retail Package | Active | Signal Conditioner | Current, Voltage, Temperature | ±25mA, ±10V | -200°C ~ 850°C | Current, Voltage | 0 ~ 24mA, ±11V | - | - | 12 ~ 24VDC | DIN Rail | Spring Terminal | -30°C ~ 55°C |
|
857-401ISOLATION AMPLIFIER; CURRENT AND |
1,754 |
|
Datasheet | 857 | Bag | Active | Isolation Amplifier | Current, Voltage | ±20mA, 0 ~ 30V (Configurable) | 0 ~ 100kOhm | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 2500V (Test) | - | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C |
|
|
2905280TWO-CHANNEL 2-WAY ISOLATOR |
4,335 |
|
Datasheet | MACX MCR | Bulk | Active | Passive Isolator | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | - | - | Loop Powered | DIN Rail | Screw Terminal | -40°C ~ 85°C |
|
857-409ISOLATION AMPLIFIER; BIPOLAR CUR |
4,275 |
|
Datasheet | 857 | Bag | Active | Isolation Amplifier | Current, Voltage | ±20mA, ±10V (Configurable) | 0 ~ 1MOhm | Current, Voltage | ±20mA, ±10V (Configurable) | 3000V (Test) | - | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C |
|
2865382TRANSDUCER MEASURING 0/4-20MA |
1,924 |
|
Datasheet | MACX MCR | Bulk | Active | Isolation Amplifier | Current | 0 ~ 20mA | - | Current | 4 ~ 20mA | 375V | - | 24VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
|
28646552 CHANNEL PASSIVE ISOLATOR |
1,114 |
|
Datasheet | MINI MCR | Bulk | Active | Passive Isolator | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | 1500V (Test) | - | Loop Powered | DIN Rail | Screw Terminal | -20°C ~ 65°C |
|
2906239MACX MCR VOLTAGE TRANSDUCER, FOR |
2,798 |
|
Datasheet | MINI MCR | Bulk | Active | Isolation Amplifier | Voltage | 0 ~ 660VAC | 240 ~ 5500kOhm | Current, Voltage | 0 ~ 20mA, 0 ~ 10V | 5300V (Test) | - | 24VDC | DIN Rail | Screw Terminal | -25°C ~ 60°C |
|
1481970000ACT20P-PRO DCDC II-S |
3,804 |
|
Datasheet | ACT20P | Bulk | Active | Signal Conditioner | Current, Voltage | ±100mA, ±300V (Configurable) | - | Current, Voltage | ±20mA, ±10V (Configurable) | 600V (Working), 5000V (Test) | - | 24 ~ 230VAC/DC | DIN Rail | Screw Terminal | -25°C ~ 70°C |
|
|
2811446ISOLATED AMP DIN RAIL |
4,695 |
|
Datasheet | MACX MCR | Bulk | Active | Signal Conditioner | Current, Voltage | ±100mA, ±100V (Configurable) | - | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 2500V (Test) | - | 12 ~ 24VDC | DIN Rail | Spring Terminal | -20°C ~ 70°C |
|
|
2811556MCR 3-WAY ISOLATING AMPLIFIER |
2,517 |
|
Datasheet | MACX MCR | Bulk | Active | Isolation Amplifier | Current, Voltage | ±100mA, ±100V (Configurable) | - | Current, Voltage | ±20mA, ±10V (Configurable) | 2500V (Test) | - | 12 ~ 24VDC | DIN Rail | Spring Terminal | -20°C ~ 70°C |
|
857-423ISOLATION AMPLIFIER; CURRENT AND |
3,879 |
|
Datasheet | - | Bulk | Active | Isolation Amplifier | Current, Voltage | - | - | Current | 0 ~ 20mA (Configurable) | 2500V | - | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C |
|
|
2811297ISOLATED AMP 2 CHAN DIN RAIL |
4,258 |
|
Datasheet | MACX MCR | Bulk | Active | Signal Conditioner | Current, Voltage | ±100mA, ±100V (Configurable) | - | Current, Voltage | ±20mA, ±10V (Configurable) | 300V (Working) | - | 24 ~ 230VAC/DC | DIN Rail | Screw Terminal | -20°C ~ 70°C |
|
857-403ISOLATION AMPLIFIER UI UI (BIP) |
2,567 |
|
Datasheet | 857 | Bulk | Active | Isolation Amplifier | Current, Voltage | ±100mA, ±500V (Configurable) | 0 ~ 1MOhm | Current, Voltage | ±20mA, ±10V (Configurable) | 2500V (Test) | - | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C |
|
RMCN22BDHARMONY ANALOG, ISOLATED ANALOG |
1,648 |
|
Datasheet | Harmony | Box | Active | Signal Conditioner | Current, Voltage | 4 ~ 20mA, 0 ~ 10V | - | Current, Voltage | 4 ~ 20mA, 0 ~ 10V | - | - | 24VDC | DIN Rail | Screw Terminal | -40°C ~ 85°C |
|
2901995SINGLE-CHANNEL INPUT LOOP-POWERE |
4,878 |
|
Datasheet | MINI MCR | Bulk | Active | Isolation Amplifier | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | 3000V (Test) | - | Loop Powered | DIN Rail | Spring Terminal | -40°C ~ 70°C |
|
2901999MINI MCR-2-I-I-PT |
3,817 |
|
Datasheet | MINI MCR | Bulk | Active | Isolation Amplifier | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | - | - | 24VDC | DIN Rail | Screw Terminal | -40°C ~ 70°C |
|
2902030MINI MCR-2-U-I4-PT |
2,802 |
|
Datasheet | MINI MCR | Bulk | Active | Signal Conditioner | Voltage | 0 ~ 10V | - | Current | 4 ~ 20mA | - | - | 24VDC | DIN Rail | Screw Terminal | -40°C ~ 70°C |
|
RMCV60BDHARMONY ANALOG, ISOLATED ANALOG |
2,424 |
|
Datasheet | Harmony | Box | Active | Signal Conditioner | Voltage | 0 ~ 500V (Configurable) | - | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | - | - | 24VDC | DIN Rail | Screw Terminal | -40°C ~ 85°C |
Frequently Asked Questions
What are Signal Conditioners and Isolators components used for?
Signal Conditioners and Isolators components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Signal Conditioners and Isolators part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Signal Conditioners and Isolators parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.