| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3BH30D LFLINE FILTER 480VAC 30A CHASS MNT |
1,486 |
|
Datasheet | 3BH | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 30 A | 50/60Hz | General Purpose | CE, CSA, cURus, SEMKO | - | Chassis Mount | Threaded Post (10-32) | - |
|
057.03013.00LINE FILTER 277V/480VAC 30A CHAS |
3,862 |
|
Datasheet | 57 | Box | Active | Three Phase (Delta) | - | - | 277V, 480V | 2.2 kV | - | 30 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -40°C ~ 85°C | Chassis Mount | Threaded Post (M6) | - |
|
RP105-16-4.7-QDLINE FILTER 250VAC 16A CHASS MNT |
1,853 |
|
Datasheet | RP105 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
080M.02002.00LINE FILTER 250VAC 20A CHASS MNT |
4,681 |
|
Datasheet | 080 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 85°C | Chassis Mount | IEC Outlet-C19, Quick Connect | - |
|
057.03012.00LINE FILTER 277V/480VAC 30A CHAS |
4,844 |
|
Datasheet | 57 | Box | Active | Single Phase | - | - | 277V, 480V | - | - | 30 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -40°C ~ 85°C | Chassis Mount | Threaded Post (M6) | - |
|
3H60D HLINE FILTER 480VAC 60A CHASS MNT |
1,179 |
|
Datasheet | 3H | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 60 A | 50/60Hz | General Purpose | CE, CSA, cURus, ENEC, SEMKO | - | Chassis Mount | Threaded Post (1/4-20) | - |
|
RPM8000-125-SLINE FLTR 480VAC 125A CHASS MNT |
2,363 |
|
Datasheet | RPM8000 | Box | Active | Three Phase (Wye) | Two Stage | - | 480V | 1.8 kV | - | 125 A | 50/60Hz, 50/400Hz | - | - | -40°C ~ 100°C | Chassis Mount | Threaded Post (M10) | - |
|
RP110-30-1-SLINE FILTER 250VAC 30A CHASS MNT |
3,277 |
|
Datasheet | RP110 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 30 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | - |
|
RP135-10-2.2-QDLINE FILTER 250VAC 10A CHASS MNT |
4,296 |
|
Datasheet | RP135 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
RP300-150-2000-SLINE FLTR 480VAC 150A CHASS MNT |
2,649 |
|
Datasheet | RP300 | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | 3.5 kV | - | 150 A | 50/60Hz | General Purpose | CE, cURus, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Threaded Post (M10) | - |
|
RP310-10-10-QDLINE FILTER 480VAC 10A CHASS MNT |
3,357 |
|
Datasheet | RP310 | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | 3.5 kV | - | 10 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
RPM8500-125-SLINE FLTR 480VAC 125A CHASS MNT |
3,838 |
|
Datasheet | RPM8500 | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | 1.8 kV | - | 125 A | 50/60Hz, 50/400Hz | - | - | -40°C ~ 100°C | Chassis Mount | Threaded Post (M10) | - |
|
RP692-600-0-BLINE FLTR 1.2KVAC 600A CHASS MNT |
4,121 |
|
Datasheet | RP692 | Box | Active | DC | Single Stage | - | 1.2kV | - | - | 600 A | - | General Purpose | CE, CSA, cURus, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
RP230-3.5-0-QDLINE FLTR 250VAC 3.5A CHASS MNT |
4,092 |
|
Datasheet | RP230 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3.5 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
RP125-80-4.7-SLINE FILTER 250VAC 80A CHASS MNT |
3,098 |
|
Datasheet | RP125 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 80 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -25°C ~ 100°C | Chassis Mount | Threaded Post (M6) | - |
|
3L15 LFLINE FILTER 440VAC 15A CHASS MNT |
2,214 |
|
Datasheet | 3L | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 15 A | 50/60Hz | General Purpose | CE, CSA, cURus, ENEC, SEMKO | - | Chassis Mount | Quick Connect | - |
|
RP230-3.5-.47-QDLINE FLTR 250VAC 3.5A CHASS MNT |
4,775 |
|
Datasheet | RP230 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 3.5 A | 50/60Hz | General Purpose | CE, cURus, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
RPM8000-30-SLINE FILTER 480VAC 30A CHASS MNT |
4,236 |
|
Datasheet | RPM8000 | Box | Active | Three Phase (Wye) | Two Stage | - | 480V | 1.8 kV | - | 30 A | 50/60Hz, 50/400Hz | - | - | -40°C ~ 100°C | Chassis Mount | Threaded Post (M5) | - |
|
RP225-12-3.3-QDLINE FILTER 250VAC 12A CHASS MNT |
1,855 |
|
Datasheet | RP225 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 12 A | 50/60Hz | General Purpose | CE, CSA, cURus, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
RP415-160-100-SLINE FLTR 480VAC 160A CHASS MNT |
3,568 |
|
Datasheet | RP415 | Box | Active | Three Phase (Wye) | Single Stage | - | 480V | 3.5 kV | - | 160 A | 50/60Hz | General Purpose | CE, CSA, cURus, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Threaded Post (M10) | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.