ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Power Line Filter Modules

Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Filter Type Configuration Voltage - Rated DC Voltage - Rated AC Voltage - Rated AC (Phase to Ground/Neutral) Voltage - Rated AC (Phase to Phase) Current Frequency - Operating Applications Approval Agency Operating Temperature Mounting Type Termination Style Inductance
091M.03001.00 Astrodyne TDI

091M.03001.00

LINE FILTER 250VAC 30A CHASS MNT

Astrodyne TDI

2,776
Datasheet 080 Box Active Single Phase Single Stage - 250V - 1.45 kV 30 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 85°C Chassis Mount IEC 320-C20, Quick Connect -
084M.00101.00-RSI Astrodyne TDI

084M.00101.00-RSI

LINE FILTER 250VAC 1A CHASS MNT

Astrodyne TDI

3,799
Datasheet 084 Box Active Single Phase Single Stage - 250V - 1.45 kV 1 A 50/60Hz General Purpose cURus, VDE -25°C ~ 85°C Chassis Mount IEC 320-C14, Quick Connect -
RP610-20-4.7-S Astrodyne TDI

RP610-20-4.7-S

LINE FILTER 250VAC 20A CHASS MNT

Astrodyne TDI

1,668
Datasheet RP610 Box Active DC Single Stage - 250V - - 20 A - General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Threaded Post (M4) -
083.01001.00 Astrodyne TDI

083.01001.00

LINE FILTER 250VAC 10A CHASS MNT

Astrodyne TDI

3,945
Datasheet 83 Box Active Single Phase Single Stage - 250V - 1.45 kV 10 A 50/60Hz General Purpose cURus, VDE -25°C ~ 85°C Chassis Mount IEC Inlet-C14, Quick Connect -
RP187-6-2.2-QD Astrodyne TDI

RP187-6-2.2-QD

LINE FILTER 250VAC 6A CHASS MNT

Astrodyne TDI

1,720
Datasheet RP187 Box Active Single Phase Two Stage - 250V - - 6 A 50/60Hz General Purpose CE, CSA, cURus, ENEC -25°C ~ 100°C Chassis Mount IEC 320-C14, Quick Connect -
RP240-50-10-S Astrodyne TDI

RP240-50-10-S

LINE FILTER 250VAC 50A CHASS MNT

Astrodyne TDI

3,765
Datasheet RP240 Box Active Single Phase Two Stage - 250V - - 50 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Threaded Post (M5) -
RP105-16-2.2-QD Astrodyne TDI

RP105-16-2.2-QD

LINE FILTER 250VAC 16A CHASS MNT

Astrodyne TDI

4,667
Datasheet RP105 Box Active Single Phase Single Stage - 250V - - 16 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Quick Connect -
085SM.02000.00 Astrodyne TDI

085SM.02000.00

LINE FILTER 250VAC 20A CHASS MNT

Astrodyne TDI

3,040
Datasheet 085S Box Active Single Phase Single Stage - 250V - - 20 A 50/60Hz General Purpose CE, cETLus, SEMKO -25°C ~ 40°C Chassis Mount IEC Inlet-C20, Quick Connect -
RP180-15-0-QD Astrodyne TDI

RP180-15-0-QD

LINE FILTER 250VAC 15A CHASS MNT

Astrodyne TDI

4,200
Datasheet RP180 Box Active Single Phase Single Stage - 250V - - 15 A 50/60Hz General Purpose CE, cURus, ENEC -25°C ~ 100°C Chassis Mount IEC 320-C14, Quick Connect -
RP692-50-2000-S Astrodyne TDI

RP692-50-2000-S

LINE FLTR 1.2KVAC 50A CHASS MNT

Astrodyne TDI

2,880
Datasheet RP692 Box Active DC Single Stage - 1.2kV - - 50 A - General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Threaded Post (M5) -
RP110-3-.47-W Astrodyne TDI

RP110-3-.47-W

LINE FILTER 250VAC 3A CHASS MNT

Astrodyne TDI

4,802
Datasheet RP110 Box Active Single Phase Single Stage - 250V - - 3 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Wire Leads -
RP135-3-2.2-QD Astrodyne TDI

RP135-3-2.2-QD

LINE FILTER 250VAC 3A CHASS MNT

Astrodyne TDI

2,370
Datasheet RP135 Box Active Single Phase Single Stage - 250V - - 3 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Quick Connect -
RP180-20-.22-QD Astrodyne TDI

RP180-20-.22-QD

LINE FILTER 250VAC 20A CHASS MNT

Astrodyne TDI

4,446
Datasheet RP180 Box Active Single Phase Single Stage - 250V - - 20 A 50/60Hz General Purpose CE, cURus, ENEC -25°C ~ 100°C Chassis Mount IEC 320-C14, Quick Connect -
RP240-100-10-S Astrodyne TDI

RP240-100-10-S

LINE FLTR 250VAC 100A CHASS MNT

Astrodyne TDI

2,118
Datasheet RP240 Box Active Single Phase Two Stage - 250V - - 100 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Threaded Post (M10) -
RP420-30-100-S Astrodyne TDI

RP420-30-100-S

LINE FILTER 480VAC 30A CHASS MNT

Astrodyne TDI

4,252
Datasheet RP420 Box Active Three Phase (Wye) Two Stage - 480V 3.8 kV - 30 A 50/60Hz General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Threaded Post (M5) -
RP428-400-1000-B Astrodyne TDI

RP428-400-1000-B

LINE FLTR 480VAC 400A CHASS MNT

Astrodyne TDI

1,906
Datasheet RP428 Box Active Three Phase (Wye) Two Stage - 480V 3.5 kV - 400 A 50/60Hz General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Terminal Post -
RP415-16-100-S Astrodyne TDI

RP415-16-100-S

LINE FILTER 480VAC 16A CHASS MNT

Astrodyne TDI

3,775
Datasheet RP415 Box Active Three Phase (Wye) Single Stage - 480V 3.5 kV - 16 A 50/60Hz General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Threaded Post (M5) -
083M.00301.00 Astrodyne TDI

083M.00301.00

LINE FILTER 250VAC 3A CHASS MNT

Astrodyne TDI

4,156
Datasheet 081 Box Active Single Phase Single Stage - 250V - 1.45 kV 3 A 50/60Hz General Purpose cURus, VDE -25°C ~ 85°C Chassis Mount IEC Inlet-C14, Quick Connect -
RP305-80-100-C Astrodyne TDI

RP305-80-100-C

LINE FILTER 480VAC 80A CHASS MNT

Astrodyne TDI

4,457
Datasheet RP305 Box Active Three Phase (Delta) Single Stage - 480V 3.5 kV - 80 A 50/60Hz General Purpose CE, CSA, cURus, SEMKO -25°C ~ 100°C Chassis Mount Terminal Block -
RP405-40-100-S Astrodyne TDI

RP405-40-100-S

LINE FILTER 480VAC 40A CHASS MNT

Astrodyne TDI

4,817
Datasheet RP405 Box Active Three Phase (Wye) Single Stage - 480V 3.5 kV - 40 A 50/60Hz General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Threaded Post (M5) -
Total 8635 Record«Prev1... 412413414415416417418419...432Next»
FAQ

Frequently Asked Questions

What are Power Line Filter Modules components used for?

Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Power Line Filter Modules part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Power Line Filter Modules?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top