Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Filter Type Configuration Voltage - Rated DC Voltage - Rated AC Voltage - Rated AC (Phase to Ground/Neutral) Voltage - Rated AC (Phase to Phase) Current Frequency - Operating Applications Approval Agency Operating Temperature Mounting Type Termination Style Inductance
RPM7020-20-QD Astrodyne TDI

RPM7020-20-QD

LINE FILTER 300VAC 20A CHASS MNT

Astrodyne TDI

2,540
Datasheet RPM7020 Box Active Single Phase Two Stage - 300V - - 20 A 50/60Hz, 50/400Hz - - -40°C ~ 100°C Chassis Mount Quick Connect -
LX15 F Astrodyne TDI

LX15 F

LINE FILTER 250VAC 15A CHASS MNT

Astrodyne TDI

3,352
Datasheet LX Box Active Single Phase Two Stage - 250V - - 15 A 50/60Hz General Purpose CE, CSA, cURus, SEMKO - Chassis Mount Quick Connect -
DSC1000-1-4.7-QD Astrodyne TDI

DSC1000-1-4.7-QD

LINE FILTER 250VAC 16A CHASS MNT

Astrodyne TDI

4,137
Datasheet DSC1000 Box Active Single Phase Two Stage - 250V - - 16 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Quick Connect -
RPM7020-20-S Astrodyne TDI

RPM7020-20-S

LINE FILTER 300VAC 20A CHASS MNT

Astrodyne TDI

1,632
Datasheet RPM7020 Box Active Single Phase Two Stage - 300V - - 20 A 50/60Hz, 50/400Hz - - -40°C ~ 100°C Chassis Mount Threaded Post (M5) -
RP186-10-0-QD Astrodyne TDI

RP186-10-0-QD

LINE FILTER 250VAC 10A CHASS MNT

Astrodyne TDI

2,748
Datasheet RP186 Box Active Single Phase Single Stage - 250V - - 10 A 50/60Hz General Purpose CE, CSA, cURus, ENEC -25°C ~ 100°C Chassis Mount IEC 320-C14, Quick Connect -
083.00101.00 Astrodyne TDI

083.00101.00

LINE FILTER 250VAC 1A CHASS MNT

Astrodyne TDI

3,844
Datasheet 83 Box Active Single Phase Single Stage - 250V - 1.45 kV 1 A 50/60Hz General Purpose cURus, VDE -25°C ~ 85°C Chassis Mount IEC Inlet-C14, Quick Connect -
LX20B H Astrodyne TDI

LX20B H

LINE FILTER 250VAC 20A CHASS MNT

Astrodyne TDI

1,979
Datasheet LX Box Active Single Phase Two Stage - 250V - - 20 A 50/60Hz General Purpose CE, CSA, cURus, SEMKO - Chassis Mount Quick Connect -
RP615-6-100-QD Astrodyne TDI

RP615-6-100-QD

LINE FILTER 250VAC 6A CHASS MNT

Astrodyne TDI

1,360
Datasheet RP615 Box Active DC Two Stage - 250V - - 6 A - General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Quick Connect -
080M.00601.00 Astrodyne TDI

080M.00601.00

LINE FILTER 250VAC 6A CHASS MNT

Astrodyne TDI

3,866
Datasheet 080 Box Active Single Phase Single Stage - 250V - - 6 A 50/60Hz General Purpose cURus, VDE -25°C ~ 85°C Chassis Mount IEC Inlet-C14, Quick Connect -
RP210-16-0-QD Astrodyne TDI

RP210-16-0-QD

LINE FILTER 250VAC 16A CHASS MNT

Astrodyne TDI

2,249
Datasheet RP210 Box Active Single Phase Two Stage - 250V - - 16 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Quick Connect -
RPM7050-20-S Astrodyne TDI

RPM7050-20-S

LINE FILTER 300VAC 20A CHASS MNT

Astrodyne TDI

2,647
Datasheet RPM7050 Box Active Single Phase Two Stage - 300V - - 20 A 50/60Hz, 50/400Hz - - -40°C ~ 100°C Chassis Mount Threaded Post (M5) -
091.00301.00 Astrodyne TDI

091.00301.00

LINE FILTER 250VAC 3A CHASS MNT

Astrodyne TDI

1,489
Datasheet 91 Box Active Single Phase Single Stage - 250V - 1.45 kV 3 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 85°C Chassis Mount IEC 320-C14, Quick Connect -
SF15 Astrodyne TDI

SF15

LINE FILTER 250VAC 15A CHASS MNT

Astrodyne TDI

2,506
Datasheet SF Box Active Single Phase Two Stage - 250V - - 15 A 50/60Hz General Purpose CE, CSA, cURus, SEMKO - Chassis Mount Quick Connect -
080M.00301.00 Astrodyne TDI

080M.00301.00

LINE FILTER 250VAC 3A CHASS MNT

Astrodyne TDI

3,063
Datasheet 080 Box Active Single Phase Single Stage - 250V - - 3 A 50/60Hz General Purpose cURus, VDE -25°C ~ 85°C Chassis Mount IEC Inlet-C14, Quick Connect -
RP600-60-4.7-C-F Astrodyne TDI

RP600-60-4.7-C-F

LINE FILTER 100VAC/VDC 60A CHASS

Astrodyne TDI

2,799
Datasheet RP600 Box Active DC Two Stage 100V 100V - - 60 A - General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Terminal Block -
RP230-20-10-W Astrodyne TDI

RP230-20-10-W

LINE FILTER 250VAC 20A CHASS MNT

Astrodyne TDI

3,803
Datasheet RP230 Box Active Single Phase Two Stage - 250V - - 20 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Wire Leads -
RP186-10-2.2-QD Astrodyne TDI

RP186-10-2.2-QD

LINE FILTER 250VAC 10A CHASS MNT

Astrodyne TDI

1,621
Datasheet RP186 Box Active Single Phase Single Stage - 250V - - 10 A 50/60Hz General Purpose CE, CSA, cURus, ENEC -25°C ~ 100°C Chassis Mount IEC 320-C14, Quick Connect -
RP692-400-2000-B Astrodyne TDI

RP692-400-2000-B

LINE FLTR 1.2KVAC 400A CHASS MNT

Astrodyne TDI

3,695
Datasheet RP692 Box Active DC Single Stage - 1.2kV - - 400 A - General Purpose CE, CSA, cURus, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Terminal Post -
RP135-200-22-S Astrodyne TDI

RP135-200-22-S

LINE FLTR 250VAC 200A CHASS MNT

Astrodyne TDI

4,614
Datasheet RP135 Box Active Single Phase Single Stage - 250V - - 200 A 50/60Hz General Purpose CE, cURus, SEMKO -25°C ~ 100°C Chassis Mount Threaded Post (M10) -
084.00101.00 Astrodyne TDI

084.00101.00

LINE FILTER 250VAC 1A CHASS MNT

Astrodyne TDI

2,984
Datasheet 84 Box Active Single Phase Single Stage - 250V - 1.45 kV 1 A 50/60Hz General Purpose cURus, VDE -25°C ~ 85°C Chassis Mount IEC 320-C14, Quick Connect -
Total 8635 Record«Prev1... 407408409410411412413414...432Next»
FAQ

Frequently Asked Questions

What are Power Line Filter Modules components used for?

Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Power Line Filter Modules part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Power Line Filter Modules?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top