| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN2210-250-99-R5LINE FLTR 1000VDC 250A CHASS MNT |
4,239 |
|
Datasheet | FN 2210 | Box | Active | DC | Single Stage | 1000V (1kV) | - | - | - | 250 A | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN2200-150-40LINE FLTR 1200VDC 150A CHASS MNT |
3,522 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 150 A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN2210-400-99-R5LINE FLTR 1000VDC 400A CHASS MNT |
1,779 |
|
Datasheet | FN 2210 | Box | Active | DC | Single Stage | 1000V (1kV) | - | - | - | 400 A | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN2211-400-99-C30-R55LINE FLTR 1000VDC 400A CHASS MNT |
3,207 |
|
Datasheet | FN 2211 | Box | Active | DC | Single Stage | 1000V (1kV) | - | - | - | 400 A | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
FN3258-130-35LINE FILTER 130A CHASSIS MOUNT |
4,778 |
|
Datasheet | FN 3258 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 130 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
STFV150-10NLINE FILTER 15A CHASSIS MOUNT |
2,710 |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | - | - | - | 15 A | 50/60Hz | General Purpose | CSA, cURus | -40°C ~ 60°C | Chassis Mount | Terminal Block | - |
|
FN2200-400-99LINE FLTR 1200VDC 400A CHASS MNT |
1,746 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 400 A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
FN3359HV-400-99LINE FILTER 400A CHASSIS MOUNT |
1,803 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 400 V | 690 V | 400 A | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3359HV-600-99LINE FILTER 600A CHASSIS MOUNT |
1,682 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 400 V | 690 V | 600 A | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
5500.2015LINE FILTER 125V/250VAC 1A TH |
4,197 |
|
Datasheet | FPP-02 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 1 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 10mH |
|
5500.2018LINE FILTER 125V/250VAC 4A TH |
4,212 |
|
Datasheet | FPP-02 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 4 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 1mH |
|
|
RSEL-2006ALINE FILTER 250VAC/VDC 6A CHASS |
1,235 |
|
Datasheet | RSEL | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 6 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
|
B84110A0000A010LINE FILTER 250VAC/VDC 1A TH |
1,595 |
|
Datasheet | B84110A | Tray | Active | Single Phase | Single Stage | 250V | 250V | - | - | 1 A | 50/60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 10mH |
|
5500.2630.01LINE FILTER 125V/250VAC 1A CHASS |
1,795 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 1 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
F1199BB03LINE FILTER 250VAC 3A CHASS MNT |
1,236 |
|
Datasheet | F1199 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Wire Leads | - |
|
5500.2041LINE FILTER 125V/250VAC 6A CHASS |
1,858 |
|
Datasheet | FMW-41 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 6 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
1EB3LINE FILTER 250VAC 1A CHASS MNT |
2,977 |
|
Datasheet | B | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 1.86mH |
|
|
F3099BB06LINE FILTER 250VAC 6A CHASS MNT |
1,342 |
|
Datasheet | F3099 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | 50/60Hz | Medical | CSA, UR, VDE | - | Chassis Mount | Wire Leads | - |
|
FHSMM10A1FRLINE FILTER 250VAC 10A CHASS MNT |
2,845 |
|
Datasheet | - | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | DC ~ 400Hz | Medical | EN, UL | -40°C ~ 110°C | Chassis Mount | Quick Connect | 300µH |
|
FHSMM06A1FRLINE FILTER 250VAC 6A CHASS MNT |
2,826 |
|
Datasheet | - | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | Medical | EN, UL | -40°C ~ 110°C | Chassis Mount | Quick Connect | 800µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.