| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
40VK6LINE FILTER 250VAC 40A CHASS MNT |
1,644 |
|
Datasheet | K | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 40 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 590µH |
|
|
FN2090Z-16-06LINE FILTER 110V/250VAC 16A CHAS |
1,970 |
|
Datasheet | FN 2090 | Tray | Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -20°C ~ 100°C | Chassis Mount | Quick Connect | 4mH |
|
|
FN2090LL-20-06LINE FILTER 250VAC/VDC 20A CHASS |
2,830 |
|
Datasheet | FN 2090 | Box | Active | Single Phase | Two Stage | 250V | 250V | - | - | 20 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2.7mH |
|
|
FN2410-16-44LINE FILTER 250VAC 16A CHASS MNT |
1,717 |
|
Datasheet | FN 2410 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
20VS6LINE FILTER 120V/250VAC 20A CHAS |
3,327 |
|
Datasheet | S | Bulk | Active | Single Phase | Two Stage | - | 120V, 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 960µH |
|
|
FN2412-8-44LINE FILTER 250VAC 8A DIN RAIL |
2,481 |
|
Datasheet | FN 2412 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 8 A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
6609048-5LINE FILTER 250VAC 6A CHASS MNT |
2,534 |
|
Datasheet | Q | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 48.8mH |
|
|
20VW6LINE FILTER 250VAC 20A CHASS MNT |
3,604 |
|
Datasheet | W | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 1.76mH |
|
FN2060B-30-08LINE FILTER 250VAC 30A CHASS MNT |
4,307 |
|
Datasheet | FN 2060 | Tray | Active | Single Phase | Two Stage | - | 250V | - | - | 30 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 600µH |
|
FN2090LL-20-08LINE FILTER 250VAC/VDC 20A CHASS |
4,573 |
|
Datasheet | FN 2090 | Box | Active | Single Phase | Two Stage | 250V | 250V | - | - | 20 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 2.7mH |
|
|
FN2070-16-08LINE FILTER 110V/250VAC 16A CHAS |
4,746 |
|
Datasheet | FN 2070 | Tray | Active | Single Phase | Two Stage | - | 110V, 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 2.8mH |
|
|
FN2412-16-44LINE FILTER 250VAC 16A DIN RAIL |
2,802 |
|
Datasheet | FN 2412 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
|
B84143A0008R105LINE FILTER 520V/300VAC 8A CHASS |
4,731 |
|
Datasheet | B84143A | Tray | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | - | - | 8 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
B84143A0016R105LINE FILTER 520V/300VAC 16A CHAS |
4,994 |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | - | - | 16 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FN2412-25-33LINE FILTER 250VAC 25A DIN RAIL |
1,582 |
|
Datasheet | FN 2412 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 25 A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
|
FN3270H-10-44LINE FILTER 480VAC 10A CHASS MNT |
2,625 |
|
Datasheet | FN 3270 | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V | 300 V | 520 V | 10 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FN2410-45-33LINE FILTER 250VAC 45A CHASS MNT |
3,891 |
|
Datasheet | FN 2410 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 45 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
5500.2065LINE FILTER 125V/250VAC 20A CHAS |
2,695 |
|
Datasheet | FMAB | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 20 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 3.5mH |
|
FMBD-345B-3612LINE FILTER 520VAC 36A CHASS MNT |
2,645 |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 36 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN2200B-25-33LINE FLTR 1200VDC 25A CHASS MNT |
3,747 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 25 A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.