Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN2030-16-08LINE FILTER 250VAC/VDC 16A CHASS |
1,755 |
|
Datasheet | FN 2030 | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 4mH |
|
5500.2612.01LINE FILTER 125V/250VAC 6A CHASS |
3,135 |
|
Datasheet | FMBB NEO | Bulk | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 6 A | - | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 7.8mH |
|
6VW1LINE FILTER 250VAC 6A CHASS MNT |
3,718 |
|
Datasheet | W | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.9mH |
|
PLF-21D5-20A-TLINE FILTER 115V/250VAC 20A CHAS |
1,809 |
|
Datasheet | PLF | Tray | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 20 A | 50 ~ 60Hz | - | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | 600µH |
|
B84742A0010R725LINE FILTER 250VAC/VDC 10A DIN |
4,160 |
|
Datasheet | B84742AxR725 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50/60Hz | Converter | UL | - | DIN Rail | Terminal Block | - |
|
NAH-20-472LINE FILTER 250VAC/VDC 20A CHASS |
4,955 |
|
Datasheet | NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
RSHN-2030LINE FILTER 250VAC/VDC 30A CHASS |
2,409 |
|
Datasheet | RSHN | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 30 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
RSMN-2020LINE FILTER 250VAC/VDC 20A CHASS |
2,541 |
|
Datasheet | RSMN | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 20 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
B84112G0000G125LINE FILTER 250VAC/VDC 25A CHASS |
3,590 |
|
Datasheet | B84112G | Tray | Active | Single Phase | Single Stage | 250V | 250V | - | - | 25 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M5) | 1.6mH |
|
|
B84112B0000B110LINE FILTER 250VAC/VDC 10A CHASS |
3,848 |
|
Datasheet | B84112B | Tray | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50/60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | 1.8mH |
|
FMAC-3RYB-2010LINE FILTER 480VAC 20A DIN RAIL |
1,859 |
|
Datasheet | FMAC RAIL | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 20 A | - | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
|
FN2090LL-12-06LINE FILTER 250VAC/VDC 12A CHASS |
3,251 |
|
Datasheet | FN 2090 | Box | Active | Single Phase | Two Stage | 250V | 250V | - | - | 12 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 4mH |
|
FN2090-10-08LINE FILTER 250VAC/VDC 10A CHASS |
3,776 |
|
Datasheet | FN 2090 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 10 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 8mH |
|
FN2060B-20-06LINE FILTER 250VAC 20A CHASS MNT |
2,083 |
|
Datasheet | FN 2060 | Tray | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH |
|
B84115E0000B030LINE FILTER 250VAC/VDC 3A CHASS |
2,318 |
|
Datasheet | B84115E | Box | Active | Single Phase | Two Stage | 250V | 250V | - | - | 3 A | 50/60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | L1 - 270µH, L2 - 16mH |
|
|
3EQ1LINE FILTER 250VAC 3A CHASS MNT |
2,379 |
|
Datasheet | Q | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 32.18mH |
|
B84114D0000B110LINE FILTER 250VAC/VDC 10A CHASS |
3,025 |
|
Datasheet | B84114D | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | Medical | CSA, ENEC, UL | - | Chassis Mount | Quick Connect | - |
|
FN343-10-05LINE FILTER 250VAC 10A CHASS MNT |
2,415 |
|
Datasheet | FN 343 | Tray | Active | Single Phase | Two Stage | - | 250V | - | - | 10 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 270µH |
|
|
RTEN-5030LINE FILTER 500VAC/VDC 30A CHASS |
3,223 |
|
Datasheet | RTEN | Bulk | Active | Three Phase (Delta) | Single Stage | 500V | 500V | - | - | 30 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN2070-10-08LINE FILTER 250VAC/VDC 10A CHASS |
3,016 |
|
Datasheet | FN 2070 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 10 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 4.5mH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.