Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
STFV300-24LLINE FILTER 240VAC 30A CHASS MNT |
4,111 |
|
Datasheet | STFV | Bulk | Active | Single Phase | Single Stage | - | 240V | - | - | 30 A | 50/60Hz | General Purpose | CSA, cURus | -40°C ~ 60°C | Chassis Mount | Terminal Block | - |
|
FN2211HV-1500-99-C17-R90LINE FILTER 1500VDC 1.5KA CHASS |
2,235 |
|
Datasheet | FN 2211 | Bulk | Active | DC | Single Stage | 1500V (1.5kV) | - | - | - | 1.5 kA | DC | Inverters, Power Drive Systems | CE, cURus | 0°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN2211HV-1500-99-C27-R99LINE FILTER 1500VDC 1.5KA CHASS |
1,386 |
|
Datasheet | FN 2211 | Bulk | Active | DC | Single Stage | 1500V (1.5kV) | - | - | - | 1.5 kA | DC | Inverters, Power Drive Systems | CE, cURus | 0°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
2-2443554-4LINE FILTER 1000VDC 1.6KA CHASS |
2,514 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1000V (1kV) | - | - | - | 1.6 kA | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
2-2443555-4LINE FILTER 1500VDC 1.6KA CHASS |
4,103 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 1.6 kA | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143B1000S024LINE FILTER 690V/400VAC 1KA CHAS |
3,227 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | 690V, 400V | - | - | 1 kA | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Block, Threaded Post (M12) | - |
|
B84143V0075R229LINE FILTER 75A CHASSIS MOUNT |
2,976 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 75 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN2210HV-2300-99-R9LINE FILTER 1500VDC 2.3KA CHASS |
4,198 |
|
Datasheet | FN 2210 | Bulk | Active | DC | Single Stage | 1500V (1.5kV) | - | - | - | 2.3 kA | DC | Inverters, Power Drive Systems | CE, cURus | 0°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143V0056R230LINE FILTER 690V/400VAC 56A CHAS |
3,065 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | 690V, 400V | - | - | 56 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143V0095R229LINE FILTER 95A CHASSIS MOUNT |
1,732 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 95 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143V0066R127LINE FILTER 66A CHASSIS MOUNT |
2,227 |
|
Datasheet | B84143V | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | - | 520 V | 66 A | 50/60Hz | Converter | cUR, UR | - | Chassis Mount | Terminal Block, Wire Leads | - |
|
B84143V0095R127LINE FILTER 95A CHASSIS MOUNT |
2,463 |
|
Datasheet | B84143V | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | - | 520 V | 95 A | 50 ~ 60Hz | Converter | cUR, UR | - | Chassis Mount | Terminal Post | 130µH |
|
B84143V0207S230LINE FILTER 207A CHASSIS MOUNT |
2,120 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 207 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block, Wire Leads | - |
|
ID-0242SLINE FLTR 250VAC/VDC 2A PANEL |
100 |
|
Datasheet | ID | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 2 A | 50 ~ 60Hz | General Purpose | CQC, CSA, ENEC, TUV, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Solder Lug | - |
|
ID-0342SLINE FLTR 250VAC/VDC 3A PANEL |
2,548 |
|
Datasheet | ID | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 3 A | 50 ~ 60Hz | General Purpose | CQC, CSA, ENEC, TUV, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Solder Lug | - |
|
IH-0242HLINE FLTR 250VAC/VDC 2A PANEL |
1,364 |
|
Datasheet | IH | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 2 A | 50 ~ 60Hz | General Purpose | CQC, CSA, ENEC, TUV, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
ID-1022HLINE FLTR 250VAC/VDC 10A PANEL |
1,375 |
|
Datasheet | ID | Tray | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | General Purpose | CQC, CSA, ENEC, TUV, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
IH-0642HLINE FLTR 250VAC/VDC 6A PANEL |
100 |
|
Datasheet | IH | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 6 A | 50 ~ 60Hz | General Purpose | CQC, CSA, ENEC, TUV, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
|
FC-LX1D2LINE FILTER 220VAC 1.5A DIN RAIL |
1,424 |
|
Datasheet | FC-LX1D2 | Tray | Not For New Designs | Single Phase | Single Stage | - | 220V | 6 kV | 4 kV | 1.5 A | - | General Purpose | - | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
IH-1022HLINE FLTR 250VAC/VDC 10A PANEL |
4,854 |
|
Datasheet | IH | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | General Purpose | CQC, CSA, ENEC, TUV, UR, VDE | -25°C ~ 85°C | Panel Mount | IEC 320-C14, Quick Connect | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.