Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN3288-230-40-C26-R65LINE FILTER 230A CHASSIS MOUNT |
2,872 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 305 V | 530 V | 230 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288-230-40-C35-R65LINE FILTER 230A CHASSIS MOUNT |
2,070 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 305 V | 530 V | 230 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
STFV300-10NLINE FILTER 30A CHASSIS MOUNT |
3,094 |
|
Datasheet | STFV | Bulk | Active | Single Phase | Single Stage | - | - | - | - | 30 A | 50/60Hz | General Purpose | CSA, cURus | -40°C ~ 60°C | Chassis Mount | Terminal Block | - |
|
1-2443555-2LINE FLTR 1500VDC 450A CHASS MNT |
2,953 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 450 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
1-2443555-5LINE FLTR 1500VDC 600A CHASS MNT |
4,485 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 600 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
1-2443554-2LINE FLTR 1000VDC 450A CHASS MNT |
4,566 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1000V (1kV) | - | - | - | 450 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
1-2443554-6LINE FLTR 1000VDC 600A CHASS MNT |
4,373 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1000V (1kV) | - | - | - | 600 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3288HVIT-230-40-C26-R60LINE FILTER 230A CHASSIS MOUNT |
4,734 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | - | 760 V | 230 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288HVIT-230-40-C34-R60LINE FILTER 230A CHASSIS MOUNT |
4,462 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | - | 760 V | 230 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3270HQ1-320-99LINE FILTER 320A CHASSIS MOUNT |
3,105 |
|
Datasheet | FN 3270 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 320 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
1-2443555-6LINE FLTR 1500VDC 600A CHASS MNT |
3,171 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 600 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143V0033R229LINE FILTER 33A CHASSIS MOUNT |
1,142 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 33 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBD-B92F-J612LINE FILTER 300/520VAC 160A CHAS |
3,397 |
|
Datasheet | FMBD NEO | Bulk | Active | Three Phase (Wye) | Two Stage | - | 300V, 520V | - | - | 160 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 400µH, L2 - 9µH |
|
B84143V0033R227LINE FILTER 33A CHASSIS MOUNT |
4,557 |
|
Datasheet | B84143V | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | - | 520 V | 33 A | 50 ~ 60Hz | Converter | cURus | - | Chassis Mount | Terminal Block | 1.8mH |
|
B84143B0400S020LINE FILTER 530/310VAC 400A CHAS |
3,594 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | 530V, 310V | - | - | 400 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
FN3270HQ1-400-99LINE FILTER 400A CHASSIS MOUNT |
3,299 |
|
Datasheet | FN 3270 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 400 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143V0050R227LINE FILTER 50A CHASSIS MOUNT |
4,713 |
|
Datasheet | B84143V | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | - | 520 V | 50 A | 50 ~ 60Hz | Converter | cURus | - | Chassis Mount | Terminal Block | 1.2mH |
|
1-2443552-7LINE FILTER 500VDC 1KA CHASS MNT |
1,736 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 500V | - | - | - | 1 kA | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
1-2443552-8LINE FILTER 500VDC 1KA CHASS MNT |
2,166 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 500V | - | - | - | 1 kA | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN2210HV-1000-99-R9LINE FLTR 1500VDC 1KA CHASS MNT |
4,671 |
|
Datasheet | FN 2210 | Bulk | Active | DC | Single Stage | 1500V (1.5kV) | - | - | - | 1 kA | DC | Inverters, Power Drive Systems | CE, cURus | 0°C ~ 100°C | Chassis Mount | Terminal Post | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.