Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
2443555-3LINE FLTR 1500VDC 150A CHASS MNT |
3,193 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 150 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
2443552-7LINE FLTR 500VDC 300A CHASS MNT |
2,163 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 500V | - | - | - | 300 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN2210HV-400-99-R9LINE FLTR 1500VDC 400A CHASS MNT |
2,780 |
|
Datasheet | FN 2210 | Bulk | Active | DC | Single Stage | 1500V (1.5kV) | - | - | - | 400 A | DC | Inverters, Power Drive Systems | CE, cURus | 0°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
2443552-8LINE FLTR 500VDC 300A CHASS MNT |
3,602 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 500V | - | - | - | 300 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3256H-120-35-R69LINE FILTER 120A CHASSIS MOUNT |
2,520 |
|
Datasheet | FN 3256 | Bulk | Active | Three Phase (Wye) | Single Stage | - | - | 300 V | 520 V | 120 A | DC ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
2443555-4LINE FLTR 1500VDC 150A CHASS MNT |
4,798 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 150 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143A0150R021LINE FILTER 760/440VAC 150A CHAS |
3,429 |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | 760V, 440V | - | - | 150 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
IE-210LINE FILTER 240VAC 10A DIN RAIL |
3,324 |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | 240V | - | - | 10 A | 47Hz, 63Hz | General Purpose | CE, cUL, UL | -40°C ~ 45°C | DIN Rail | Terminal Block | - |
|
2443555-7LINE FLTR 1500VDC 300A CHASS MNT |
1,752 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 300 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
2443554-4LINE FLTR 1000VDC 150A CHASS MNT |
1,474 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1000V (1kV) | - | - | - | 150 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
IE-120LINE FILTER 20A DIN RAIL |
2,974 |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | - | - | - | 20 A | 47Hz, 63Hz | General Purpose | CE, cUL, UL | -40°C ~ 45°C | DIN Rail | Terminal Block | - |
|
FN3270HQ1-150-99LINE FILTER 150A CHASSIS MOUNT |
3,279 |
|
Datasheet | FN 3270 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 150 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143V0016R127LINE FILTER 16A CHASSIS MOUNT |
3,836 |
|
Datasheet | B84143V | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | - | 520 V | 16 A | 50 ~ 60Hz | Converter | cUR, UR | - | Chassis Mount | Terminal Post | 130µH |
|
1-2443552-5LINE FLTR 500VDC 600A CHASS MNT |
1,112 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 500V | - | - | - | 600 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
2443552-9LINE FLTR 500VDC 450A CHASS MNT |
4,141 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 500V | - | - | - | 450 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
1-2443554-0LINE FLTR 1000VDC 450A CHASS MNT |
1,425 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1000V (1kV) | - | - | - | 450 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84142A0600S081LINE FLTR 800VDC 600A CHASS MNT |
4,289 |
|
Datasheet | B84142A | Bulk | Active | Single Phase | Two Stage | 800V | - | - | - | 600 A | 50 ~ 60Hz | Converter | cUL, cUR, UL,UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN2210HV-600-99-R9LINE FLTR 1500VDC 600A CHASS MNT |
4,169 |
|
Datasheet | FN 2210 | Bulk | Active | DC | Single Stage | 1500V (1.5kV) | - | - | - | 600 A | DC | Inverters, Power Drive Systems | CE, cURus | 0°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
2443555-9LINE FLTR 1500VDC 450A CHASS MNT |
4,367 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 450 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
1-2443555-0LINE FLTR 1500VDC 450A CHASS MNT |
4,414 |
|
Datasheet | EVX | Box | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 450 A | DC | Converter | UR | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.