Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
B84143A0050R000LINE FILTER 480V/275VAC 50A CHAS |
4,157 |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 275V | 275 V | 480 V | 50 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, ENEC, UL | - | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
|
B84299D6300B000LINE FILTER 250VAC 30A CHASS MNT |
4,796 |
|
Datasheet | B84299D6 | Tray | Active | Single Phase | Two Stage | - | 250V | - | - | 30 A | 50/60Hz | General Purpose | cUL, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M4), Wire Leads | - |
|
|
RTHN-5030LINE FILTER 500VAC/VDC 30A CHASS |
2,242 |
|
Datasheet | RTHN | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | 500V | - | - | 30 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84144A0050R140LINE FILTER 50A CHASSIS MOUNT |
2,255 |
|
Datasheet | B84144 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 520 V | 300 V | 50 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
RTHB-5020LINE FILTER 500VAC/VDC 20A CHASS |
1,741 |
|
Datasheet | RTHB | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | 500V | - | - | 20 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN3280H-25-33-R69LINE FILTER 25A CHASSIS MOUNT |
2,133 |
|
Datasheet | FN 3280 | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 300 V | 520 V | 25 A | DC ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBC-A91Q-3010LINE FILTER 480V/520VAC 30A CHAS |
3,439 |
|
Datasheet | FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 30 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.9mH, L2 - 10µH |
|
FMBC-R91C-1612LINE FILTER 520VAC 16A CHASS MNT |
3,454 |
|
Datasheet | FMBC LL | Bulk | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 16 A | - | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84144A0066R140LINE FILTER 66A CHASSIS MOUNT |
4,208 |
|
Datasheet | B84144 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 520 V | 300 V | 66 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
F3480T032LINE FILTER 480VAC 32A CHASS MNT |
1,313 |
|
Datasheet | F3480 | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 32 A | 50/60Hz | General Purpose | CE, UR | - | Chassis Mount | Terminal Block | - |
|
B84143V0011R227LINE FILTER 11A CHASSIS MOUNT |
4,978 |
|
Datasheet | B84143V | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | - | 520 V | 11 A | 50 ~ 60Hz | Converter | cURus | - | Chassis Mount | Terminal Block | 4.5mH |
|
FN3270HQ1-65-34LINE FILTER 65A CHASSIS MOUNT |
4,212 |
|
Datasheet | FN 3270 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 65 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84144A0025R000LINE FILTER 440V/250VAC 25A CHAS |
1,274 |
|
Datasheet | B84144 | Bulk | Active | Three Phase (Wye) | Single Stage | - | 440V, 250V | 250 V | 440 V | 25 A | 50 ~ 60Hz | General Purpose | UL | - | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
FN2230-300-99-C0000-R90LINE FLTR 500VDC 300A CHASS MNT |
2,667 |
|
Datasheet | FN2230 | Bulk | Active | DC | Two Stage | 500V | - | - | - | 300 A | DC | General Purpose | CE, CSA, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M10) | - |
|
B84143A0050R021LINE FILTER 760V/440VAC 50A CHAS |
1,403 |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | 760V, 440V | - | - | 50 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
IE-205LINE FILTER 240VAC 5A DIN RAIL |
2,015 |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | 240V | - | - | 5 A | 47Hz, 63Hz | General Purpose | CE, cUL, UL | -40°C ~ 45°C | DIN Rail | Terminal Block | - |
|
B84143A0100R106LINE FILTER 100A CHASSIS MOUNT |
4,866 |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 520 V | 300 V | 100 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN2240-150-99-C0000-R90LINE FLTR 1000VDC 150A CHASS MNT |
1,287 |
|
Datasheet | FN2240 | Bulk | Active | DC | Two Stage | 1000V (1kV) | - | - | - | 150 A | DC | General Purpose | CE, CSA, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Quick Connect, Threaded Post (M10) | - |
|
IE-105LINE FILTER 5A DIN RAIL |
2,838 |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | - | - | - | 5 A | 47Hz, 63Hz | General Purpose | CE, cUL, UL | -40°C ~ 45°C | DIN Rail | Terminal Block | - |
|
|
FMER-G92R-J017LINE FLTR 1200VDC 100A CHASS MNT |
1,951 |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 100 A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.