Signal Conditioners and Isolators
Explore Signal Conditioners and Isolators parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Type | Input Range (Current, Voltage) | Input Range (Additional) | Output Type | Output Range | Isolation | Features | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
2904090MACX MCR-SL-RPSS-2I-2I-SP |
1,769 |
|
Datasheet | MACX MCR | Bulk | Active | Isolation Amplifier | Current | 0 ~ 20mA | - | Current | 4 ~ 20mA | - | - | 24VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
RN22-CB2AINTERFACE MODULE |
2,423 |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - |
|
RN22-8L2AINTERFACE MODULE |
1,806 |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - |
|
3RS70052KE00SWITCHABLE MULTI-RANGE CNVRTR, 2 |
4,761 |
|
Datasheet | 3RS7 | Box | Active | Isolation Amplifier | Current, Resistance, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 100 Ohm, 330k Ohm | - | - | 50V | - | 24VAC/DC | DIN Rail | Spring Terminal | -25°C ~ 60°C |
|
3RS70051KE00SWITCHABLE MULTI-RANGE CNVRTR, 2 |
1,390 |
|
Datasheet | 3RS7 | Box | Active | Isolation Amplifier | Current, Resistance, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 100 Ohm, 330k Ohm | - | - | 50V | - | 24VAC/DC | DIN Rail | Screw Terminal | -25°C ~ 60°C |
|
1105515SIGNAL CONDITIONER ISO AMP |
3,668 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - |
|
2904962TRANSDUCER CURRENT 24VDC |
1,168 |
|
Datasheet | MACX | Bulk | Obsolete | Isolation Amplifier | Current | 4 ~ 20mA | - | Current | 4 ~ 20mA | 1500V | - | 24V | DIN Rail | Spring Terminal | -20°C ~ 60°C |
|
IAMS0020MOD IAMS DUAL SETPOINT |
1,838 |
|
Datasheet | IAMS | Bulk | Active | Signal Conditioner | Current, Voltage, Resistance, Temperature | 0 ~ 20mA, 0 ~ 10V (Configurable) | 0.01 ~ 100kOhm, -200°C ~ 2300°C | Current, Voltage | 0 ~ 20mA, 0 ~ 12V (Configurable) | 2300V | Alarm Relay (2) | 21.6 ~ 253VAC, 19.2 ~ 300VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
2495700000ACT20P-AI-AO-AC-P |
4,687 |
|
Datasheet | ACT20P | Box | Active | Signal Conditioner | Current | 0 ~ 22mA (Configurable) | - | Current, Voltage | 0 ~ 22mA, 0 ~ 11V (Configurable) | 2000V | - | 90 ~ 264VAC | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
3RS70252FE00SWTCHBL MULTI-RANGE CNVRTR, 24VA |
4,919 |
|
Datasheet | 3RS7 | Box | Active | Signal Conditioner | Current, Resistance, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 100 Ohm, 330k Ohm | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 50V | - | 24VAC/DC | DIN Rail | Spring Terminal | -25°C ~ 60°C |
|
3RS70251FE00SWTCHBL MULTI-RANGE CNVRTR, 24VA |
1,537 |
|
Datasheet | 3RS7 | Box | Active | Isolation Amplifier | Current, Resistance, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 100 Ohm, 330k Ohm | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 50V | - | 24VAC/DC | DIN Rail | Screw Terminal | -25°C ~ 60°C |
|
DSCA33-05ESIGNAL CONDITIONER TRUE RMS DIN |
1,215 |
|
Datasheet | DSCA | Bag | Active | Signal Conditioner | Voltage | 0 ~ 300V | - | Current | 0 ~ 20mA | 1500V | - | 19 ~ 29VDC | DIN Rail | Screw Terminal | -40°C ~ 80°C |
|
DSCA33-01CSIGNAL CONDITIONER TRUE RMS DIN |
3,415 |
|
Datasheet | DSCA | Bag | Active | Signal Conditioner | Voltage | 0 ~ 100mV | - | Current | 4 ~ 20mA | 1500V | - | 19 ~ 29VDC | DIN Rail | Screw Terminal | -40°C ~ 80°C |
|
DSCA33-07SIGNAL CONDITIONER TRUE RMS DIN |
4,433 |
|
Datasheet | DSCA | Bag | Active | Signal Conditioner | Current | 0 ~ 5A | - | Voltage | 0 ~ 10V | 1500V | - | 19 ~ 29VDC | DIN Rail | Screw Terminal | -40°C ~ 80°C |
|
DSCA33-06CSIGNAL CONDITIONER TRUE RMS DIN |
2,920 |
|
Datasheet | DSCA | Bag | Active | Signal Conditioner | Current | 0 ~ 1A | - | Current | 4 ~ 20mA | 1500V | - | 19 ~ 29VDC | DIN Rail | Screw Terminal | -40°C ~ 80°C |
|
857-569POWER SIGNAL CONDITIONER; CURREN |
3,926 |
|
Datasheet | 857 | Bag | Active | Signal Conditioner | Current, Voltage | 0 ~ 5A, 300VAC/DC | 15 ~ 70Hz, 0 ~ 10mOhms | Current, Voltage | 0 ~ 20mA, 0 ~ 10V (Configurable) | 2500V (Test) | - | 24VDC | DIN Rail | Spring Terminal | -40°C ~ 70°C |
|
|
2907706TWO-CHANNEL 2-WAY ISOLATOR |
2,020 |
|
Datasheet | MACX MCR | Bulk | Active | Passive Isolator | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | - | - | Loop Powered | DIN Rail | Screw Terminal | -40°C ~ 85°C |
|
2907707MACX MCR-SL-2I-2I-HV-ILP-SP |
1,322 |
|
Datasheet | MACX MCR | Bulk | Active | Signal Conditioner | Current | 0 ~ 20mA | - | Current | 0 ~ 20mA | 5000V | - | 6 ~ 30VDC | DIN Rail | Spring Terminal | -40°C ~ 85°C |
|
IAMS0002MOD IAMS ANALOG OUTPUT |
3,550 |
|
Datasheet | IAMS | Bulk | Active | Signal Conditioner | Current, Voltage, Resistance, Temperature | 0 ~ 20mA, 0 ~ 10V (Configurable) | 0.01 ~ 100kOhm, -200°C ~ 2300°C | Current, Voltage | 0 ~ 20mA, 0 ~ 12V (Configurable) | 2300V | Alarm Relay (2) | 21.6 ~ 253VAC, 19.2 ~ 300VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C |
|
2904959TRANSDUCER CURRENT 24VDC |
4,784 |
|
Datasheet | MACX | Bulk | Obsolete | Isolation Amplifier | Current | 4 ~ 20mA | - | Current | 4 ~ 20mA | 1500V | - | 24V | DIN Rail | Spring Terminal | -20°C ~ 60°C |
Frequently Asked Questions
What are Signal Conditioners and Isolators components used for?
Signal Conditioners and Isolators components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Signal Conditioners and Isolators part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Signal Conditioners and Isolators parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.