Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN251-24-07LINE FILTER 440VAC 24A CHASS MNT |
3,106 |
|
Datasheet | FN 251 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | 440V | - | - | 24 A | DC ~ 60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block, Wire Leads | 1mH |
|
FN251-4-07LINE FILTER 440VAC 4A CHASS MNT |
1,176 |
|
Datasheet | FN 251 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | 440V | - | - | 4 A | DC ~ 60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block, Wire Leads | 7mH |
|
FN3110-50-52LINE FILTER 50A CHASSIS MOUNT |
3,563 |
|
Datasheet | FN 3100 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 50 A | DC ~ 60Hz | Regenerative Motor Drive | CSA, SEMKO, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3110-80-35LINE FILTER 80A CHASSIS MOUNT |
1,287 |
|
Datasheet | FN 3100 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 80 A | DC ~ 60Hz | Regenerative Motor Drive | CSA, SEMKO, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
ZRAC2220-11LINE FILTER 250VAC 20A CHASS MNT |
2,745 |
|
Datasheet | ZRAC-11 | Bulk | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 20 A | - | General Purpose | CSA, NEMKO, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
ZRAC2210-11LINE FILTER 250VAC 10A CHASS MNT |
4,866 |
|
Datasheet | ZRAC-11 | Bulk | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 10 A | - | General Purpose | CSA, NEMKO, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
5003.136B.1LINE FILTER 125VDC 10A PANEL MNT |
3,097 |
|
Datasheet | 5003 | Bulk | Obsolete | Single Phase | Single Stage | 125V | - | - | - | 10 A | - | Signal | cURus, ENEC, UL, VDE | -25°C ~ 85°C | Panel Mount | PC Pins | 400µH |
|
|
B84111A0000K010LINE FILTER 250VAC/VDC 1A CHASS |
3,888 |
|
Datasheet | B84111A | Tray | Obsolete | Single Phase | Single Stage | 250V | 250V | - | - | 1 A | 50/60Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | IEC 320-C14, Quick Connect | 1.5mH |
|
|
B84299D6101A003LINE FLTR 277VAC 100A CHASS MNT |
1,146 |
|
Datasheet | B84299D6 | Tray | Active | Single Phase | Three Stage | - | 277V | - | - | 100 A | 50/60Hz | General Purpose | cUL, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M10), Wire Leads | - |
|
|
B84299D6050B003LINE FILTER 250VAC 5A CHASS MNT |
1,070 |
|
Datasheet | B84299D6 | Tray | Active | Single Phase | Three Stage | - | 250V | - | - | 5 A | 50/60Hz | General Purpose | cUL, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M4), Wire Leads | - |
|
B84143B0150R110LINE FILTER 520/300VAC 150A CHAS |
4,909 |
|
Datasheet | B84143B | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | 520V, 300V | - | - | 150 A | 50/60Hz | General Purpose | ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | - |
|
|
B84142A0030R122LINE FILTER 300VAC/VDC 30A CHASS |
4,337 |
|
Datasheet | B84142A | Tray | Obsolete | Single Phase | Two Stage | 300V | 300V | - | - | 30 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
B84112B0000K030LINE FILTER 250VAC/VDC 3A CHASS |
1,960 |
|
Datasheet | B84112B | Tray | Obsolete | Single Phase | Single Stage | 250V | 250V | - | - | 3 A | 50/60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 85°C | Chassis Mount | Quick Connect | 10mH |
|
1609163-6LINE FILTER 100A CHASSIS MOUNT |
3,788 |
|
Datasheet | CDEFX | Bulk | Active | - | - | - | - | - | - | 100 A | - | General Purpose | - | - | Chassis Mount | - | - |
|
FN5040-4.5-82LINE FILTER 4.5A CHASSIS MOUNT |
4,062 |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 4.5 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 13mH |
|
FN5040-10-83LINE FILTER 10A CHASSIS MOUNT |
3,946 |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 10 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 5.2mH |
|
FN5040-24-84LINE FILTER 24A CHASSIS MOUNT |
2,544 |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 24 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 2.4mH |
|
FN5040-48-85LINE FILTER 48A CHASSIS MOUNT |
3,883 |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 48 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 1.1mH |
|
FN5040-62-86LINE FILTER 62A CHASSIS MOUNT |
2,783 |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 62 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 850µH |
|
FN5040-75-87LINE FILTER 75A CHASSIS MOUNT |
1,265 |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 75 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 750µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.