Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
FN3258-75-52LINE FILTER 75A CHASSIS MOUNT |
3,129 |
|
Datasheet | FN 3258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 75 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
F4804ALINE FLTR 80VAC 4A SURFACE MOUNT |
3,700 |
|
Datasheet | F | Tape & Reel (TR) | Obsolete | Single Phase | Three Stage | - | 80V | - | - | 4 A | - | General Purpose | DEMKO, UL | -40°C ~ 85°C | Surface Mount | SMD (SMT) Tab | - |
|
FN2360B-3-06LINE FILTER 250VAC 3A CHASS MNT |
4,115 |
|
Datasheet | FN 2360 | Tray | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 3 A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 400µH |
|
FN2360B-6-06LINE FILTER 250VAC 6A CHASS MNT |
4,474 |
|
Datasheet | FN 2360 | Tray | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.7mH |
|
FN2360W-3-06LINE FILTER 250VAC 3A CHASS MNT |
1,028 |
|
Datasheet | FN 2360 | Tray | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 3 A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 400µH |
|
FN2360X-6-06LINE FILTER 250VAC 6A CHASS MNT |
2,717 |
|
Datasheet | FN 2360 | Tray | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | General Purpose | CSA, SEMKO | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.7mH |
|
FN256-120-28LINE FILTER 120A CHASSIS MOUNT |
1,501 |
|
Datasheet | FN 256 | Tray | Obsolete | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 120 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN256-120-35LINE FILTER 120A CHASSIS MOUNT |
2,353 |
|
Datasheet | FN 256 | Tray | Obsolete | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 120 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN256-160-28LINE FILTER 160A CHASSIS MOUNT |
2,266 |
|
Datasheet | FN 256 | Tray | Obsolete | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 160 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN256-160-40LINE FILTER 160A CHASSIS MOUNT |
3,269 |
|
Datasheet | FN 256 | Tray | Obsolete | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 160 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN258-250-40LINE FILTER 250A CHASSIS MOUNT |
4,546 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 250 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3258H-16-45LINE FILTER 16A CHASSIS MOUNT |
3,926 |
|
Datasheet | FN 3258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 16 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3258H-30-47LINE FILTER 30A CHASSIS MOUNT |
4,990 |
|
Datasheet | FN 3258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 30 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3258H-42-47LINE FILTER 42A CHASSIS MOUNT |
4,174 |
|
Datasheet | FN 3258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 42 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3258H-55-52LINE FILTER 55A CHASSIS MOUNT |
4,902 |
|
Datasheet | FN 3258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 55 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3258H-7-45LINE FILTER 7A CHASSIS MOUNT |
2,987 |
|
Datasheet | FN 3258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 7 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FN3258H-75-52LINE FILTER 75A CHASSIS MOUNT |
3,231 |
|
Datasheet | FN 3258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 75 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3258P-42-47LINE FILTER 42A CHASSIS MOUNT |
2,193 |
|
Datasheet | FN 3258 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 42 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN351-280-37LINE FILTER 280A CHASSIS MOUNT |
4,273 |
|
Datasheet | FN 351 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 250 V | 440 V | 280 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN251-16-07LINE FILTER 440VAC 16A CHASS MNT |
1,785 |
|
Datasheet | FN 251 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | 440V | - | - | 16 A | DC ~ 60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block, Wire Leads | 2.6mH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.