| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TAC-300-333LINE FLTR 500VAC 300A CHASS MNT |
1,248 |
|
Datasheet | TAC | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 300 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84299D2160B003LINE FILTER 250VAC 16A CHASS MNT |
2,194 |
|
Datasheet | - | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 16 A | 50 ~ 60Hz | General Purpose | - | -25°C ~ 40°C | Chassis Mount | Threaded Post (M8) | - |
|
RTEN-5200J9J3-00LINE FILTER 200A CHASSIS MOUNT |
2,228 |
|
Datasheet | RTEN-J9J3-00 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 500 V | 500 V | 200 A | - | General Purpose | ENEC | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN351H-280-37LINE FILTER 280A CHASSIS MOUNT |
3,560 |
|
Datasheet | FN 351 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 280 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
RTHC-5200LINE FILTER 500VAC/VDC 200A CHAS |
2,117 |
|
Datasheet | RTHC | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | 500V | - | - | 200 A | - | General Purpose | EN | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
RTHN-5200LINE FILTER 500VAC/VDC 200A CHAS |
2,904 |
|
Datasheet | RTHN | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | 500V | - | - | 200 A | - | General Purpose | EN | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
F3480T322LINE FLTR 480VAC 322A CHASS MNT |
3,171 |
|
Datasheet | F3480 | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 322 A | 50/60Hz | General Purpose | CE, UR | - | Chassis Mount | Terminal Block | - |
|
B84143C0800S251LINE FILTER 800A CHASSIS MOUNT |
2,142 |
|
Datasheet | B84143C*S251 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 440 V | 760 V | 800 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | - | Chassis Mount | Terminal Post | - |
|
FN3311HV-2300-99-C18-R55LINE FILTER 2.3KA CHASSIS MOUNT |
4,198 |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 440 V | 760 V | 2.3 kA | DC ~ 60Hz | Inverters, Power Drive Systems | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
RTEN-5250J9J3-00LINE FILTER 250A CHASSIS MOUNT |
1,566 |
|
Datasheet | RTEN-J9J3-00 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 500 V | 500 V | 250 A | - | General Purpose | ENEC | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143K1250S081LINE FLTR 760/440VAC 1.25KA CHAS |
2,237 |
|
Datasheet | B84143K | Box | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | 760 V | 440 V | 1.25 kA | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN5020-55-34LINE FILTER 55A CHASSIS MOUNT |
1,488 |
|
Datasheet | FN 5020 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 288 V | 500 V | 55 A | - | Regenerative Motor Drive | - | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | - |
|
B84143C1000S250LINE FILTER 1KA CHASSIS MOUNT |
3,727 |
|
Datasheet | B84143C*S250 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 305 V | 530 V | 1 kA | 50 ~ 60Hz | Converter | cUR, ENEC, UR | - | Chassis Mount | Terminal Post | - |
|
FN3311HVIT-2300-99-C18-R5LINE FILTER 2.3KA CHASSIS MOUNT |
1,172 |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 440 V | 760 V | 2.3 kA | DC ~ 60Hz | Inverters, Power Drive Systems | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84299D2320B003LINE FILTER 250VAC 32A CHASS MNT |
1,679 |
|
Datasheet | - | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 32 A | 50 ~ 60Hz | General Purpose | - | -25°C ~ 40°C | Chassis Mount | Threaded Post (M8) | - |
|
B84143B1600S080LINE FILTER 1.6KA CHASSIS MOUNT |
3,882 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 520 V | 300 V | 1.6 kA | 50 ~ 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Post | 130µH |
|
1609071-2LINE FILTER 63A CHASSIS MOUNT |
1,372 |
|
Datasheet | ADT | Bulk | Obsolete | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 63 A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Threaded Post (3/8-16) | - |
|
FN2200R-2300-99LINE FILTER 1200VDC 2.3KA CHASS |
2,216 |
|
Datasheet | FN 2200 | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 2.3 kA | - | Photovoltaic Inverter | cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FSB-80-324-HLINE FILTER 500VAC 80A CHASS MNT |
1,963 |
|
Datasheet | FSB | Box | Active | Three Phase (Delta) | Two Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
1000APH12PLINE FILTER 690VAC 1KA CHASS MNT |
2,168 |
|
Datasheet | APH | Bulk | Active | Three Phase (Delta) | Three Stage | - | 690V | - | - | 1 kA | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.