| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN5030-55-34LINE FILTER 55A CHASSIS MOUNT |
4,138 |
|
Datasheet | FN 5030 | Tray | Obsolete | Three Phase (Delta) | Three Stage | - | - | 288 V | 500 V | 55 A | - | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | - |
|
TAC-250-103LINE FLTR 500VAC 250A CHASS MNT |
4,243 |
|
Datasheet | TAC | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 250 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
TAC-250-223LINE FLTR 500VAC 250A CHASS MNT |
4,604 |
|
Datasheet | TAC | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 250 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
TAC-250-333LINE FLTR 500VAC 250A CHASS MNT |
1,294 |
|
Datasheet | TAC | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 250 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143C0800S250LINE FILTER 800A CHASSIS MOUNT |
3,656 |
|
Datasheet | B84143C*S250 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 305 V | 530 V | 800 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | - | Chassis Mount | Terminal Post | - |
|
FN5420-26-33-E2FXTLINE FILTER 26A CHASSIS MOUNT |
1,401 |
|
Datasheet | FN 5420 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 480 V | 530 V | 26 A | DC ~ 60Hz | Regenerative Motor Drive | CE, cURus, UKCA | -40°C ~ 70°C | Chassis Mount | Terminal Block | 1.7mH |
|
FN3310HV-2300-99-R5LINE FILTER 2.3KA CHASSIS MOUNT |
3,038 |
|
Datasheet | FN 3310 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 440 V | 760 V | 2.3 kA | DC ~ 60Hz | Inverters, Power Drive Systems | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
600TYSS104LINE FILTER 480VAC CHASSIS MOUNT |
1,987 |
|
Datasheet | TYS | Box | Active | Three Phase (Wye) | Single Stage | - | 480V | - | - | - | 50/60Hz | General Purpose | - | - | Chassis Mount | Terminal Post | 3µH |
|
FTB-150-203-HLINE FLTR 500VAC 150A CHASS MNT |
3,820 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-150-324-HLINE FLTR 500VAC 150A CHASS MNT |
4,141 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-150-663-HLINE FLTR 500VAC 150A CHASS MNT |
4,244 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-150-203-HSLINE FLTR 500VAC 150A CHASS MNT |
3,798 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-150-663-HSLINE FLTR 500VAC 150A CHASS MNT |
1,257 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMCC-H93F-S652LINE FILTER 1.6KA CHASSIS MOUNT |
1,893 |
|
Datasheet | FMCC SOL | Box | Active | Three Phase (Delta) | Three Stage | - | - | 520 V | 760 V | 1.6 kA | 50 ~ 60Hz | General Purpose | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post, Threaded Post (M12) | - |
|
|
1000APH12LLINE FILTER 520VAC 1KA CHASS MNT |
4,693 |
|
Datasheet | APH | Bulk | Active | Three Phase (Delta) | Three Stage | - | 520V | - | - | 1 kA | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
B84143V0075R227LINE FILTER 75A CHASSIS MOUNT |
4,786 |
|
Datasheet | B84143V | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | - | 520 V | 75 A | 50 ~ 60Hz | Converter | cURus | - | Chassis Mount | Terminal Block | 0.86mH |
|
B84143B1250S081LINE FLTR 760/440VAC 1.25KA CHAS |
4,851 |
|
Datasheet | B84143B | Box | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | 760 V | 440 V | 1.25 kA | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
RSHN-2300LINE FILTER 250VAC/VDC 300A CHAS |
4,899 |
|
Datasheet | RSHN | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 300 A | - | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84299D2160B201EMP-FILTER 2X16A, 250VAC, 40KA |
4,942 |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
TAC-300-223LINE FLTR 500VAC 300A CHASS MNT |
1,015 |
|
Datasheet | TAC | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 300 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.