Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
FN3120H-150-40LINE FILTER 150A CHASSIS MOUNT |
4,010 |
|
Datasheet | FN 3120 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 150 A | DC ~ 60Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN530-4-99LINE FILTER 4A CHASSIS MOUNT |
3,525 |
|
Datasheet | FN 530 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 288 V | 500 V | 4 A | - | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | - |
|
FN3311-600-99-C16-R55LINE FILTER 520/300VAC 600A CHAS |
4,595 |
|
Datasheet | FN 3311 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | 300 V | 520 V | 600 A | 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143B0400S080LINE FILTER 400A CHASSIS MOUNT |
3,399 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | - | 300 V | 400 A | 50 ~ 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Post | 130µH |
|
B84233A1500R000LINE FILTER 530V/305VAC 50A CHAS |
2,213 |
|
Datasheet | LeaXield™ | Box | Active | Three Phase (Delta) | Single Stage | - | 530V, 305V | - | - | 50 A | - | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN2200B-600-99LINE FLTR 1200VDC 600A CHASS MNT |
3,866 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 600 A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3120H-230-40LINE FILTER 230A CHASSIS MOUNT |
3,694 |
|
Datasheet | FN 3120 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 230 A | DC ~ 60Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84143B0600S080LINE FILTER 600A CHASSIS MOUNT |
1,871 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | - | 300 V | 600 A | 50 ~ 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Post | 130µH |
|
FN2210-1500-99-R5LINE FILTER 1000VDC 1.5KA CHASS |
1,275 |
|
Datasheet | FN 2210 | Box | Active | DC | Single Stage | 1000V (1kV) | - | - | - | 1.5 kA | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
300 AHV S FPLINE FILTER 300A CHASSIS MOUNT |
3,760 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 300 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
|
B84143B0600S020LINE FILTER 530/310VAC 600A CHAS |
1,975 |
|
Datasheet | B84143B | Tray | Active | Three Phase (Delta) | Two Stage | - | 530V, 310V | - | - | 600 A | 50/60Hz | Inverters, Power Drive Systems | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
FN2200B-800-99LINE FLTR 1200VDC 800A CHASS MNT |
1,598 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 800 A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN530-16-99LINE FILTER 16A CHASSIS MOUNT |
4,476 |
|
Datasheet | FN 530 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 288 V | 500 V | 16 A | - | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block, Wire Leads | - |
|
FN2200-1000-99LINE FLTR 1200VDC 1KA CHASS MNT |
4,152 |
|
Datasheet | FN 2200 | Tray | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 1 kA | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143B1000S080LINE FILTER 1KA CHASSIS MOUNT |
1,064 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 520 V | 300 V | 1 kA | 50 ~ 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Post | 130µH |
|
FN3100-300-99LINE FILTER 300A CHASSIS MOUNT |
3,525 |
|
Datasheet | FN 3100 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 300 A | DC ~ 60Hz | Regenerative Motor Drive | CSA, SEMKO, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FN2200B-1000-99LINE FLTR 1200VDC 1KA CHASS MNT |
1,434 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 1 kA | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143V0050R229LINE FILTER 50A CHASSIS MOUNT |
3,595 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 50 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN3359HV-800-99LINE FILTER 800A CHASSIS MOUNT |
4,674 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 400 V | 690 V | 800 A | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3359HV-1000-99LINE FILTER 1KA CHASSIS MOUNT |
3,586 |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 400 V | 690 V | 1 kA | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.