| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
6609068-4LINE FILTER 25A CHASSIS MOUNT |
1,840 |
|
Datasheet | AYC | Bulk | Active | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 25 A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
FMAC-0934-5010LINE FILTER 480V/520VAC 50A CHAS |
3,905 |
|
Datasheet | FMAC | Bag | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 50 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1mH |
|
FLLD3100AMHT6LINE FILTER 100A CHASSIS MOUNT |
3,817 |
|
Datasheet | * | Bulk | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 305 V | 530 V | 100 A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
STFV050-10NLINE FILTER 5A CHASSIS MOUNT |
2,371 |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | - | - | - | 5 A | 50/60Hz | General Purpose | CSA, cURus | -40°C ~ 60°C | Chassis Mount | Terminal Block | - |
|
FN2200B-100-35LINE FLTR 1200VDC 100A CHASS MNT |
3,404 |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 100 A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
STFV025-24LLINE FLTR 240VAC 2.5A CHASS MNT |
4,907 |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | 240V | - | - | 2.5 A | 50/60Hz | General Purpose | CSA, cURus | -40°C ~ 60°C | Chassis Mount | Terminal Block | - |
|
FN3287-80-34-C33-R65LINE FILTER 530V/305VAC 80A CHAS |
1,323 |
|
Datasheet | FN 3287 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBC-394D-J812LINE FLTR 520VAC 180A CHASS MNT |
2,763 |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 180 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBC-394D-J814LINE FLTR 760VAC 180A CHASS MNT |
2,893 |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 180 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FN3100-35-33LINE FILTER 35A CHASSIS MOUNT |
3,296 |
|
Datasheet | FN 3100 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 35 A | DC ~ 60Hz | Regenerative Motor Drive | CSA, SEMKO, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FMAD-0932-2510LINE FILTER 277V/480VAC 25A CHAS |
1,499 |
|
Datasheet | FMAD | Bulk | Active | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 25 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 2.6mH |
|
FN3288-80-34-C17-R65LINE FILTER 530V/305VAC 80A CHAS |
3,191 |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
60KEVD10AFPWLINE FILTER 440VAC 60A CHASS MNT |
1,066 |
|
Datasheet | KEV | Box | Active | Three Phase (Wye) | Two Stage | - | 440V | - | - | 60 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN3288-80-34-C26-R65LINE FILTER 530V/305VAC 80A CHAS |
1,816 |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
36FCD10LINE FILTER 36A CHASSIS MOUNT |
2,760 |
|
Datasheet | FCD | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 36 A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
FN3288-80-34-C35-R65LINE FILTER 530V/305VAC 80A CHAS |
3,583 |
|
Datasheet | FN 3288 | Tray | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMAD-395D-K312LINE FILTER 300/520VAC 230A CHAS |
3,466 |
|
Datasheet | FMAD | Box | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 230 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288IT-80-34-C34-R60LINE FILTER 80A CHASSIS MOUNT |
1,582 |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | - | - | - | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
STFE030-10NLINE FILTER 3A DIN RAIL |
4,512 |
|
Datasheet | STFE | Bulk | Active | Single Phase | Single Stage | - | - | - | - | 3 A | 47Hz, 63Hz | General Purpose | CE, cURus | -40°C ~ 50°C | DIN Rail | Terminal Block | - |
|
FMBD-395D-K312LINE FLTR 520VAC 230A CHASS MNT |
1,604 |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 230 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.