Current/Voltage Transducer Monitors
Explore Current/Voltage Transducer Monitors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output | Isolation | Response Time | Accuracy | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ISOBLOCK V-4C (5V 5V)VOLTAGE SEN W/GALVANIC ISOLATION |
3,146 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±5V | ±5V | 1500V (Working) | 2.8µs | ±0.2% | 12 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | CE |
|
ISOBLOCK V-4C (50MV 5V)VOLTAGE SEN W/GALVANIC ISOLATION |
4,017 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±50mV | ±5V | 1500V (Working) | 2.8µs | ±0.2% | 12 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | CE |
|
ISOBLOCK V-4C (20V 5V)VOLTAGE SEN W/GALVANIC ISOLATION |
1,646 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±20V | ±5V | 1500V (Working) | 2.8µs | ±0.2% | 12 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | CE |
|
P51000K11-M2M/11CURRENT TRANSDUCER 2000 VDC |
4,575 |
|
Datasheet | ProLine | Box | Active | Voltage Transducer | ±300mV (Configurable) | ±20mA, ±10V (Configurable) | 2000VAC/DC (Working), 10000VAC (Test) | 45µs | ±0.1% | 24 ~ 230VAC/DC | DIN Rail | Screw Terminal | -40°C ~ 85°C | UL |
|
P51000K11-M1M/11CURRENT TRANSDUCER 2000 VDC |
4,095 |
|
Datasheet | ProLine | Box | Active | Voltage Transducer | ±100mV (Configurable) | ±20mA, ±10V (Configurable) | 2000VAC/DC (Working), 10000VAC (Test) | 45µs | ±0.1% | 24 ~ 230VAC/DC | DIN Rail | Screw Terminal | -40°C ~ 85°C | UL |
|
ISOBLOCK V-4C (50V 5V)TRANSDUCER VOLTAGE 9-28VDC |
3,178 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±50V | ±5V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
P43000D2CURRENT TRANSDUCER 2200 VDC |
1,750 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±5A (Configurable) | ±20mA, ±10V (Configurable) | 2200VAC/DC (Working), 10000VAC (Test) | 110µs | ±0.3% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | - |
|
P51100K11-M1M/11CURRENT TRANSDUCER 4800 VDC |
3,464 |
|
Datasheet | ProLine | Box | Active | Voltage Transducer | ±100mV (Configurable) | ±20mA, ±10V (Configurable) | 4800VAC/DC (Working), 16000VAC (Test) | 45µs | ±0.1% | 24 ~ 230VAC/DC | DIN Rail | Screw Terminal | -40°C ~ 85°C | UL |
|
P51100K11-M2M/11CURRENT TRANSDUCER 4800 VDC |
3,072 |
|
Datasheet | ProLine | Box | Active | Voltage Transducer | ±300mV (Configurable) | ±20mA, ±10V (Configurable) | 4800VAC/DC (Working), 16000VAC (Test) | 45µs | ±0.1% | 24 ~ 230VAC/DC | DIN Rail | Screw Terminal | -40°C ~ 85°C | UL |
|
P52000K11-M5M/11VOLTAGE TRANSDUCER 2000 VDC |
3,966 |
|
Datasheet | ProLine | Box | Active | Voltage Transducer | ±900V (Configurable) | ±20mA, ±10V (Configurable) | 2000VAC/DC (Working), 10000VAC (Test) | 60µs | ±0.1% | 24 ~ 230VAC/DC | DIN Rail | Screw Terminal | -40°C ~ 85°C | UL |
|
ISOBLOCK Q-4CISOLATION AMPLIFIER |
1,956 |
|
Datasheet | IsoBlock Q | Box | Active | Voltage Transducer | - | ±10V | 2500V (Working) | 5µs | ±0.2% | 2 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | CE |
|
ISOBLOCK V-4C (500VAC 7VAC0.1%)TRANSDUCER VOLTAGE 9-28VDC |
3,244 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | 0 ~ 500VAC | 0 ~ 7VAC | 1500V (Working) | 2.8µs | ±0.1% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-4C (250VAC 7VAC0.1%)TRANSDUCER VOLTAGE 9-28VDC |
1,354 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | 0 ~ 250VAC | 0 ~ 7VAC | 1500V (Working) | 2.8µs | ±0.1% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK Q-4C (HR)TRANSDUCER VOLTAGE 9-28VDC |
4,036 |
|
Datasheet | IsoBlock Q | Box | Active | Voltage Transducer | - | ±10V | 2500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK Q-4C (LR)TRANSDUCER VOLTAGE 9-28VDC |
3,120 |
|
Datasheet | IsoBlock Q | Box | Active | Voltage Transducer | - | ±10V | 2500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
P43100D2-0005CURRENT TRANSDUCER 3600 VDC |
1,618 |
|
Datasheet | VariTrans | Box | Active | Voltage Transducer | ±5A | ±20mA | 3600VAC/DC (Working), 15000VAC (Test) | 110µs | ±0.3% | 20 ~ 253VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 70°C | - |
|
ISOBLOCK V-4C (1500V 10V0.1%)TRANSDUCER VOLTAGE 9-28VDC |
2,493 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±1500V | ±10V | 1500V (Working) | 2.8µs | ±0.1% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-4C (1000V 10V0.1%)TRANSDUCER VOLTAGE 9-28VDC |
2,106 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±1000V | ±10V | 1500V (Working) | 2.8µs | ±0.1% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-4C (750V 10V0.1%)TRANSDUCER VOLTAGE 9-28VDC |
2,050 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±750V | ±10V | 1500V (Working) | 2.8µs | ±0.1% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
ISOBLOCK V-4C (500V 10V0.1%)TRANSDUCER VOLTAGE 9-28VDC |
2,931 |
|
Datasheet | IsoBlock V | Box | Active | Voltage Transducer | ±500V | ±10V | 1500V (Working) | 2.8µs | ±0.1% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
Frequently Asked Questions
What are Current/Voltage Transducer Monitors components used for?
Current/Voltage Transducer Monitors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current/Voltage Transducer Monitors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Current/Voltage Transducer Monitors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.