Uninterruptible Power Supply (UPS) Systems
Explore Uninterruptible Power Supply (UPS) Systems parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Voltage - Input | Applications | Form | Power - Rated | AC Outlets | Backup Time - Max Load | Media Lines Protected | Voltage - Output | Input Connector | Output Connector | Cord Length | Approval Agency | Size / Dimension | Height |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SU1500RTXL2UUPS TRUEONLINE 1.5KVA 1200W 6OUT |
3,811 |
|
Datasheet | Smart Online™ | - | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 1.5kVA / 1200W | 6 (UPS) | 5 minutes | - | 120V | NEMA 5-15P | NEMA 5-15R | 10' (3.05m) | - | 20.787" L x 17.520" W (528.00mm x 445.00mm) | 3.500" (88.90mm) |
|
SU1000XLAUPS TRUE ONLINE 1000VA 800W 6OUT |
3,047 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Tower | 1kVA / 800W | 6 (UPS) | 4.5 minutes | RJ45 | 120V | NEMA 5-15P | NEMA 5-15R | 10' (3.05m) | - | 13.201" L x 6.799" W (335.30mm x 172.70mm) | 10.000" (254.00mm) |
|
SU1000RTXL2UAUPS TRUE ONLINE 1.0KVA 800W 6OUT |
2,802 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 1kVA / 800W | 6 (UPS) | 4.5 minutes | RJ45 | 120V | NEMA 5-15P | NEMA 5-15R | 10' (3.05m) | - | 13.500" L x 17.500" W (342.90mm x 444.50mm) | 3.500" (88.90mm) |
|
SU1500RTXL2UAUPS TRUEONLINE 1.5KVA 1200W 6OUT |
3,867 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 1.5kVA / 1200W | 6 (UPS) | 5 minutes | RJ45 | 120V | NEMA 5-15P | NEMA 5-15R | 10' (3.05m) | - | 19.000" L x 17.500" W (482.60mm x 444.50mm) | 3.500" (88.90mm) |
|
SU2200RTXL2UAUPS TRUEONLINE 2.2KVA 1600W 7OUT |
1,932 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 2.2kVA / 1600W | 7 (UPS) | 4.5 minutes | RJ45 | 120V | NEMA 5-20P | NEMA 5-20R (6), NEMA L5-20R (1) | 10' (3.05m) | - | 20.787" L x 17.520" W (528.00mm x 445.00mm) | 3.500" (88.90mm) |
|
SU5000RT3UHVUPS SMARTONLINE 5KVA 3500W 4OUT |
1,059 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 5kVA / 3500W | 4 (UPS) | 8 minutes | - | 200V, 208V, 220V, 240V | NEMA L6-30P | NEMA L6-20R (2), NEMA L6-30R (2) | 10' (3.05m) | - | 26.000" L x 17.480" W (660.40mm x 444.50mm) | 5.201" (132.10mm) |
|
SU5000RT3UUPS SMARTONLINE 5KVA 3500W 16OUT |
2,498 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 5kVA / 3500W | 16 (UPS) | 8 minutes | - | 120V, 208V | NEMA L6-30P | NEMA 5-20R (12), NEMA L6-20R (2), NEMA L6-30R (2) | 10' (3.05m) | - | 26.000" L x 17.480" W (660.40mm x 444.50mm) | 5.201" (132.10mm) |
|
SMART2200VSXLUPS SMARTPRO 2.2KVA 1600W 10OUT |
4,313 |
|
Datasheet | Smart Pro® | Bulk | Obsolete | Line Interactive (Input Regulation) | - | Network, Single Phase | Tower | 2.2kVA / 1600W | 10 (UPS) | 7 minutes | - | 120V | NEMA 5-20P | NEMA 5-15R (7), NEMA 5-20R (2), NEMA L5-20R (1) | 8' (2.44m) | - | 12.000" L x 9.201" W (304.80mm x 233.70mm) | 14.201" (360.70mm) |
|
SU20K3/3UPS SMARTONLINE 20KVA 16KW IGBT |
1,074 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, 3-Phase | Tower | 20kVA / 16000W | - | 5 minutes | - | 120V, 208V (3-Phase) | Hardwired | Hardwired | - | - | 36.799" L x 19.500" W (934.70mm x 495.30mm) | 35.902" (911.90mm) |
|
SU30K3/3UPS SMARTONLINE 30KVA 24KW IGBT |
3,431 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, 3-Phase | Tower | 30kVA / 24000W | - | 5 minutes | - | 120V, 208V (3-Phase) | Hardwired | Hardwired | - | - | 37.902" L x 19.500" W (962.70mm x 495.30mm) | 35.902" (911.90mm) |
|
HT850UPSUPS 750VA 450W 12OUT RJ11 COAX |
4,935 |
|
Datasheet | Home Theater | Bulk | Obsolete | Line Interactive (Input Regulation) | - | Desktop, Home Theater | Desktop | 750VA / 450W | 12 (6 UPS, 6 Surge Only) | 4 minutes | Type F Coax, RJ11 | 120V | NEMA 5-15P | NEMA 5-15R | 6' (1.83m) | - | 7.000" L x 12.000" W (177.80mm x 304.80mm) | 4.000" (101.60mm) |
|
INTRNT OFFC300UPS 300VA 150W 6OUT RJ/45 |
1,382 |
|
Datasheet | Internet Office® | Bulk | Obsolete | Standby (No Regulation) | - | Desktop, Home Theater | Desktop | 300VA / 150W | 6 (3 UPS, 3 Surge Only) | 4 minutes | RJ45 | 120V | NEMA 5-15P | NEMA 5-15R | 6' (1.83m) | - | 4.500" L x 11.000" W (114.30mm x 279.40mm) | 2.598" (66.00mm) |
|
OMNI500ISOUPS 500VA 300W 3OUT USB TOWER |
3,104 |
|
Datasheet | OmniSmart™ | Bulk | Obsolete | Line Interactive (Input Regulation) | - | Desktop, Home Theater | Tower | 500VA / 300W | 3 (UPS) | 5 minutes | - | 120V | NEMA 5-15P | NEMA 5-15R | 6' (1.83m) | - | 7.500" L x 5.201" W (190.50mm x 132.10mm) | 10.799" (274.30mm) |
|
SMART700SERUPS 700VA 450W 6OUT SERIAL |
2,375 |
|
Datasheet | Smart Pro® | Bulk | Obsolete | Line Interactive (Input Regulation) | - | Network, Single Phase | Tower | 700VA / 450W | 6 (UPS) | 6 minutes | - | 120V | NEMA 5-15P | NEMA 5-15R | 7' (2.13m) | - | 7.756" L x 7.244" W (197.00mm x 184.00mm) | 11.732" (298.00mm) |
|
SU10000RT3U2TFUPS 10KVA 9000W 30OUT RACK MOUNT |
1,565 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 10kVA / 9000W | 30 (UPS) | 4.3 minutes | - | 120V, 208V | Hardwired | NEMA 5-20R (24), NEMA L6-20R (4), NEMA L6-30R (2) | - | - | 26.213" L x 17.500" W (655.80mm x 444.50mm) | 5.142" (130.60mm) |
|
SU10K3/1XUPS 10KVA 8KW 220V 3-PHASE TOWER |
3,700 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, 3-Phase | Tower | 10kVA / 8000W | - | 4 minutes | - | 220V, 230V, 240V (3-Phase) | Hardwired | Hardwired | - | - | 24.803" L x 10.984" W (630.00mm x 279.00mm) | 22.205" (564.00mm) |
|
SU2200XLUPS 2200VA 1600W 7OUT SERIAL |
4,804 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Tower | 2.2kVA / 1600W | 7 (UPS) | 6 minutes | - | 120V | NEMA 5-20P | NEMA 5-20R (6), NEMA L5-20R (1) | 10' (3.05m) | - | 16.772" L x 5.512" W (426.00mm x 140.00mm) | 14.764" (375.00mm) |
|
SU3000RTXL3UHVUPS 3KVA 2400W 8OUT RACK MOUNT |
3,920 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 3kVA / 2400W | 8 (UPS) | 5 minutes | - | 200V, 208V, 220V, 240V | NEMA L6-20P | NEMA 6-20R (6), NEMA L6-20R (2) | 10' (3.05m) | - | 21.000" L x 17.500" W (533.40mm x 444.50mm) | 5.252" (133.40mm) |
|
SU3000RTXR3UUPS 3KVA 2400W 9OUT RACK MOUNT |
4,191 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Rackmount | 3kVA / 2400W | 9 (UPS) | 12 minutes | RJ45 | 120V | NEMA L5-30P | NEMA 5-15R (4), NEMA 5-20R (4), NEMA L5-30R (1) | 10' (3.05m) | - | 26.000" L x 17.799" W (660.40mm x 452.10mm) | 5.201" (132.10mm) |
|
SU3000XLUPS 3KVA 2400W 9OUT SERIAL |
4,193 |
|
Datasheet | Smart Online™ | Bulk | Obsolete | Online (Double Conversion) | - | Network, Single Phase | Tower | 3kVA / 2400W | 9 (UPS) | 5 minutes | RJ45 | 120V | NEMA L5-30P | NEMA 5-15R (4), NEMA 5-20R (4), NEMA L5-30R (1) | 10' (3.05m) | - | 20.500" L x 9.000" W (520.70mm x 228.60mm) | 10.299" (261.60mm) |
Frequently Asked Questions
What are Uninterruptible Power Supply (UPS) Systems components used for?
Uninterruptible Power Supply (UPS) Systems components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Uninterruptible Power Supply (UPS) Systems part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Uninterruptible Power Supply (UPS) Systems parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.