Uninterruptible Power Supply (UPS) Systems
Explore Uninterruptible Power Supply (UPS) Systems parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Voltage - Input | Applications | Form | Power - Rated | AC Outlets | Backup Time - Max Load | Media Lines Protected | Voltage - Output | Input Connector | Output Connector | Cord Length | Approval Agency | Size / Dimension | Height |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SVT10KXSMARTONLINE SVTX SERIES 3-PHASE |
4,402 |
|
Datasheet | SmartOnline | Bulk | Active | Online (Double Conversion) | - | General Purpose, Industrial Control | Tower | 10kVA / 9000W | - | 3.8 minutes | - | 220V, 230V, 240V (3-Phase) | Hardwired | Hardwired | - | - | 32.000" L x 9.800" W (812.80mm x 248.92mm) | 33.900" (861.06mm) |
|
9PXM08CDXXXMOTORS & SOLENIODS |
4,183 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
9PX8KPMEATON 9PX 8KVA 7.2KW 208V POWER |
2,708 |
|
Datasheet | - | Box | Active | Online (Double Conversion) | 200VAC, 208VAC, 220VAC, 230VAC, 240VAC | Network, Single Phase | Rackmount, Tower | 8kVA / 7200W | - | - | RS-232 | 208V | Hardwired | Hardwired | - | CE, cULus, FCC, NOM | 27.559" L x 17.323" W (700.00mm x 440.00mm) | 5.118" (130.00mm) |
|
9PXM08JKXXXMOTORS & SOLENIODS |
3,994 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SU6000RT4UTFUPS SMART ONLINE RACKMOUNT |
2,844 |
|
Datasheet | * | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
9PXM08EFXXXMOTORS & SOLENIODS |
1,237 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
9PX3000GRT-LEATON 9PX 3000VA 2400W 208V ONLI |
4,657 |
|
Datasheet | - | Box | Active | Online (Double Conversion) | 200VAC, 208VAC, 220VAC, 230VAC, 240VAC | General Purpose, Industrial Control | Rackmount, Tower | 3kVA / 2.4kW | 10 (UPS) | 3 minutes | RS-232 | 200V, 208V, 220V, 230V, 240V | NEMA L6-20P | IEC 320-C13 (8), IEC 320-C19 (2) | 6' (1.83m) | cTUVus, NOM | 28.400" L x 17.300" W (721.36mm x 439.42mm) | 10.200" (259.08mm) |
|
9PX1500RT-L-PP9PX1500RT-L WITH EMB SU |
2,571 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
9PXM08EJXXXMOTORS & SOLENIODS |
1,887 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
S4K2U3000CUPS ON LINE 3000VA 120V 3G |
4,723 |
|
Datasheet | S4K | Bulk | Obsolete | Online (Double Conversion) | - | General Purpose, Industrial Control | Rackmount, Tower | 3kVA / 2700W | 7 | - | - | 110V, 115V, 120V, 127V | NEMA 5-30P | NEMA 5-30R (1), NEMA 5-20R (6) | 10' (3.05m) | - | 23.701" L x 16.929" W (602.00mm x 430.00mm) | 3.402" (86.40mm) |
|
5PX2000RT3UG2-PPP5PX2000RT3UNG2 WITH EMB SU & PP |
4,954 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SV10000RT120PSTACO SV10000RT120P DOUBLE CONVE |
1,600 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SV10000T120PSTACO SV10000T120P DOUBLE CONVER |
4,138 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SU6KRT3UHV208/240V 6000VA 6000W ON-LINE UP |
2,890 |
|
Datasheet | SmartOnline® | Bulk | Active | Online (Double Conversion) | 200VAC, 208VAC, 240VAC | Desktop, Home Theater, Network, Single Phase | Rackmount | 6kVA / 6000W | 6 (UPS) | 3 minutes | RS-232 | 200V, 208V, 220V, 230V, 240V | NEMA L6-30P, Hardwired | Hardwired, NEMA L6-30R (4), NEMA L6-20R (2) | 10' (3.05m) | CSA, FCC, UL | 30.000" L x 17.500" W (762.00mm x 444.50mm) | 5.140" (130.56mm) |
|
9PX2000RT-PPP9PX2000RT WITH EMB SU & PP |
1,036 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SU6KRT3UG200240V 6000VA 6000W ON-LINE UPS |
3,513 |
|
Datasheet | SmartOnline® | Bulk | Active | Online (Double Conversion) | 200VAC, 208VAC, 220VAC, 230VAC, 240VAC | Desktop, Home Theater, Network, Single Phase | Rackmount | 6kVA / 6000W | 8 (UPS) | 3 minutes | RS-232 | 200V, 208V, 220V, 230V, 240V | Hardwired | C13 (4), C19 (4), Hardwired | - | CE, CSA, FCC | 30.000" L x 17.500" W (762.00mm x 444.50mm) | 5.140" (130.56mm) |
|
5PX2000RTG2-PPP5PX2000RTNG2 WITH EMB SU & PP |
1,454 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
S4K2U30005CUPS ON LINE 3000VA 230V 3G |
3,735 |
|
Datasheet | S4K | Bulk | Obsolete | Online (Double Conversion) | - | General Purpose, Industrial Control | Rackmount, Tower | 3kVA / 2700W | 7 | - | - | 110V, 115V, 120V, 127V | NEMA 5-30P | NEMA 5-30R (1), NEMA 5-20R (6) | 10' (3.05m) | - | 23.701" L x 16.929" W (602.00mm x 430.00mm) | 3.402" (86.40mm) |
|
9PX2000RT-L-PP9PX2000RT-L WITH EMB SU |
1,313 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
784834-01APC UNINTERRUPTIBLE POWER SUPPLY |
2,359 |
|
Datasheet | APC | Box | Active | - | - | General Purpose, Industrial Control | Rackmount | - | - | - | - | 120V | - | - | - | - | - | - |
Frequently Asked Questions
What are Uninterruptible Power Supply (UPS) Systems components used for?
Uninterruptible Power Supply (UPS) Systems components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Uninterruptible Power Supply (UPS) Systems part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Uninterruptible Power Supply (UPS) Systems parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.