Time Delay Relays
Explore Time Delay Relays parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Relay Type | Function | Circuit | Delay Time | Contact Rating @ Voltage | Voltage - Supply | Termination Style | Timing Adjustment Method | Timing Initiate Method | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
55XU-P8-CU-ROHSRELAY TIME DELAY 30HR 5A 250V |
3,022 |
|
Datasheet | 55XU | Box | Active | Socketable | Mechanical Relay | Interval, On-Delay | DPDT (2 Form C) | 0 Sec ~ 30 Hrs | 5A @ 250VAC/24VDC | 20 ~ 240VAC, 12 ~ 240VDC | Plug In, 8 Pin (Octal) | Hand Dial | Input Voltage | - | - |
|
|
QAS2S110ADLRELAY TIME DELAY 2 SEC CHAS MT |
1,617 |
|
Datasheet | QAS | Box | Active | Chassis Mount | Solid State Relay | On-Delay | SPDT (1 Form C) | Fixed, 2 Sec | - | 110VAC/DC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage | - | - |
|
|
H3RN-11 DC24RELAY TIME DELAY 10HR 3A 250V |
2,789 |
|
Datasheet | H3RN | Bulk | Active | Socketable | Mechanical Relay | Programmable (Multi-Function) | SPDT (1 Form C) | 0.1 Min ~ 10 Hrs | 3A @ 250VAC | 24VDC | Plug In | Thumbwheel Switches | Input Voltage | - | - |
|
KSD2221RELAY TIME DELAY 100SEC CHAS MT |
1,590 |
|
Datasheet | KSD2 | Bulk | Active | Chassis Mount | Solid State Relay | Interval | SPST-NO (1 Form A) | 1 Sec ~ 100 Sec | - | 24VAC | Quick Connect - 0.250" (6.3mm) | External Resistor | Input Voltage | - | - |
|
XB5DTB24RELAY TIME DELAY 10MIN PNL MT |
2,788 |
|
Datasheet | Harmony | Box | Active | Panel Mount | Timer Only, Relay Not Included | Programmable (Multi-Function) | - | 0.5 Min ~ 10 Min | - | 24VDC | Screw Terminal | - | Input Voltage | - | - |
|
CT45S45RELAY TIME DELAY 45SEC CHAS MT |
1,195 |
|
Datasheet | CT | Bulk | Active | Chassis Mount | Solid State Relay | Off-Delay, On-Delay | SPST-NO (1 Form A) | Fixed, 45 Sec | - | 24VAC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage | - | - |
|
|
KSDB324NRELAY TIME DELAY 100MIN CHAS MT |
2,131 |
|
Datasheet | KSDB | Bulk | Active | Chassis Mount | Solid State Relay | Off-Delay | SPST-NO (1 Form A) | 1 Min ~ 100 Min | - | 24VDC | Quick Connect - 0.250" (6.3mm) | External Resistor | Input Voltage, Trigger Signal | - | - |
|
MSM11W6RELAY TIME DELAY 1 SEC CHAS MT |
4,411 |
|
Datasheet | MSM | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | Fixed, 1 Sec | - | 12VDC | Wire Leads | Fixed | Input Voltage | - | - |
|
MSM42W6RELAY TIME DELAY 2 SEC CHAS MT |
2,929 |
|
Datasheet | MSM | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | Fixed, 2 Sec | - | 120VAC | Wire Leads | Fixed | Input Voltage | - | - |
|
ATS-P120RELAY TIME DELAY 59SEC 16A 240V |
4,170 |
|
Datasheet | ATS | Box | Active | DIN Rail | Mechanical Relay | Programmable (Multi-Function) | SPDT (1 Form C) | 1 Sec ~ 59 Sec | 16A @ 240VAC | 110 ~ 240VAC | Screw Terminal | Up/Down Digit Keys | Input Voltage | - | - |
|
|
TAC1413RELAY TIME DELAY 3SEC CHAS MT |
1,517 |
|
Datasheet | TAC1 | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | Fixed, 3 Sec | - | 120VAC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage | - | - |
|
XB5DTGM2RELAY TIME DELAY 10SEC PNL MT |
4,612 |
|
Datasheet | Harmony | Box | Active | Panel Mount | Timer Only, Relay Not Included | Programmable (Multi-Function) | - | 0.5 Sec ~ 10 Sec | - | 110 ~ 230VAC/DC | Screw Terminal | - | Input Voltage | - | - |
|
|
TDUH3000ARELAY TIME DELAY 10230SEC CHAS |
4,435 |
|
Datasheet | TDUH | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | 10 Sec ~ 10230 Sec | - | 24 ~ 120VAC/DC | Quick Connect - 0.250" (6.3mm) | DIP Switches | Input Voltage | - | - |
|
|
KSD2420RELAY TIME DELAY 10SEC CHAS MT |
2,229 |
|
Datasheet | KSD2 | Bulk | Active | Chassis Mount | Solid State Relay | Interval | SPST-NO (1 Form A) | 0.1 Sec ~ 10 Sec | - | 120VAC | Quick Connect - 0.250" (6.3mm) | External Resistor | Input Voltage | - | - |
|
|
QASP60S220ADLRELAY TIME DELAY 60SEC CHAS MT |
2,290 |
|
Datasheet | QAS | Tray | Active | Chassis Mount | Solid State Relay | On-Delay | SPDT (1 Form C) | 0.6 Sec ~ 60 Sec | - | 220VAC/DC | Quick Connect - 0.250" (6.3mm) | Screwdriver Slot | Input Voltage | - | - |
|
|
QASP100S24ADLRELAY TIME DELAY 100SEC CHAS MT |
2,472 |
|
Datasheet | QAS | Box | Active | Chassis Mount | Solid State Relay | On-Delay | SPDT (1 Form C) | 1 Sec ~ 100 Sec | - | 24VAC/DC | Quick Connect - 0.250" (6.3mm) | Screwdriver Slot | Input Voltage | - | - |
|
XB5DTGM3RELAY TIME DELAY 60SEC PNL MT |
3,486 |
|
Datasheet | Harmony | Box | Active | Panel Mount | Timer Only, Relay Not Included | Programmable (Multi-Function) | - | 3 Sec ~ 60 Sec | - | 110 ~ 230VAC/DC | Screw Terminal | - | Input Voltage | - | - |
|
|
TA12D2RELAY TIME DELAY 2 MIN CHAS MT |
3,923 |
|
Datasheet | TA | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | Fixed, 2 Min | - | 12VDC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
|
H3DK-GE AC240-440RELAY TIME DELAY 120 SEC 5A 250V |
4,154 |
|
Datasheet | H3DK-G | Bulk | Active | DIN Rail | Mechanical Relay | Star Delta Controller | SPDT (1 Form C) | 1 Sec ~ 120 Sec | 5A @ 250VAC | 240 ~ 440VAC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
TS14130RELAY TIME DELAY 30SEC CHAS MT |
1,621 |
|
Datasheet | TS1 | Bulk | Active | Chassis Mount | Solid State Relay | On-Delay | SPST-NO (1 Form A) | Fixed, 30 Sec | - | 120VAC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage | - | - |
Frequently Asked Questions
What are Time Delay Relays components used for?
Time Delay Relays components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Time Delay Relays part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Time Delay Relays parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.