ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Time Delay Relays

Explore Time Delay Relays parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Relay Type Function Circuit Delay Time Contact Rating @ Voltage Voltage - Supply Termination Style Timing Adjustment Method Timing Initiate Method Grade Qualification
88226013 Crouzet

88226013

RELAY TIME DELAY 12MIN 5A 230V

Crouzet

3,105
Datasheet 88220 Box Obsolete Panel Mount Mechanical Relay Programmable (Multi-Function) SPST-NO (1 Form A), SPDT (1 Form C) 0.3 Sec ~ 12 Min 5A @ 230VAC 24VAC Screw Terminal Hand Dial Input Voltage - -
88226014 Crouzet

88226014

RELAY TIME DELAY 12HR 5A 230V

Crouzet

3,725
Datasheet 88220 Box Obsolete Panel Mount Mechanical Relay Programmable (Multi-Function) SPST-NO (1 Form A), SPDT (1 Form C) 0.3 Min ~ 12 Hrs 5A @ 230VAC 220 ~ 240VAC Screw Terminal Hand Dial Input Voltage - -
88226029 Crouzet

88226029

RELAY TIME DELAY 24V 60HZ 12M

Crouzet

4,311
Datasheet - Box Obsolete - - - - - - - - - - - -
88226503 Crouzet

88226503

RELAY TIME DELAY 12MIN 5A 230V

Crouzet

1,381
Datasheet 88220 Box Obsolete Socketable Mechanical Relay Programmable (Multi-Function) SPST-NO (1 Form A), SPDT (1 Form C) 0.3 Sec ~ 12 Min 5A @ 230VAC 110 ~ 127VAC Plug In, 8 Pin (Octal) Hand Dial Input Voltage - -
88829108 Crouzet

88829108

RELAY TIME DELAY 20HR 5A 230V

Crouzet

4,974
Datasheet EMYR8 Box Obsolete DIN Rail Mechanical Relay Programmable (Multi-Function) SPDT (1 Form C) 0.1 Sec ~ 20 Hrs 5A @ 230VAC 24 ~ 240VAC, 12 ~ 240VDC Screw Terminal Hand Dial Input Voltage - -
88895207 Crouzet

88895207

RELAY TIME DELAY 10HR 5A 250V

Crouzet

3,727
Datasheet RTM Box Obsolete Socketable Mechanical Relay On-Delay DPDT (2 Form C) 0.1 Sec ~ 10 Hrs 5A @ 250VAC 230VAC Plug In Hand Dial Input Voltage - -
88896207 Crouzet

88896207

RELAY TIME DELAY 10HR 5A 250V

Crouzet

2,714
Datasheet RTM Box Obsolete Socketable Mechanical Relay On-Delay 4PDT (4 Form C) 0.1 Sec ~ 10 Hrs 5A @ 250VAC 230VAC Plug In Hand Dial Input Voltage - -
S1DX-S2C1S-DC12V Panasonic Industrial Automation Sales

S1DX-S2C1S-DC12V

RELAY TIME DELAY ONE SHOT 2FORMC

Panasonic Industrial Automation Sales

1,388
Datasheet S1DX Bulk Obsolete Socketable Mechanical Relay On-Delay DPDT (2 Form C) 0.1 Sec ~ 1 Sec 7A @ 250VAC 12VDC Plug In Hand Dial Input Voltage - -
S1DX-S2C5S-DC24V Panasonic Industrial Automation Sales

S1DX-S2C5S-DC24V

RELAY TIME DELAY ONE SHOT 2FORMC

Panasonic Industrial Automation Sales

1,799
Datasheet S1DX Bulk Obsolete Socketable Mechanical Relay On-Delay DPDT (2 Form C) 0.2 Sec ~ 5 Sec 7A @ 250VAC 24VDC Plug In Hand Dial Input Voltage - -
7022QE TE Connectivity Aerospace, Defense and Marine

7022QE

RELAY TIME DELAY 200SEC 10A 240V

TE Connectivity Aerospace, Defense and Marine

3,833
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay DPDT (2 Form C) 20 Sec ~ 200 Sec 10A @ 240VAC 12VDC Screw Terminal Hand Dial Input Voltage - -
7012AKLX TE Connectivity Aerospace, Defense and Marine

7012AKLX

RELAY TIME DELAY 300SEC 10A 240V

TE Connectivity Aerospace, Defense and Marine

4,768
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay On-Delay DPDT (2 Form C) 1 Sec ~ 300 Sec 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
5-1423164-9 TE Connectivity Aerospace, Defense and Marine

5-1423164-9

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

3,341
Datasheet - Bulk Active - - - - - - - - - - - -
1755142-3 TE Connectivity Aerospace, Defense and Marine

1755142-3

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

1,403
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay DPDT (2 Form C) 1.5 Sec ~ 15 Sec 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
7024ABT TE Connectivity Aerospace, Defense and Marine

7024ABT

RELAY TIME DELAY 5SEC 10A 400V

TE Connectivity Aerospace, Defense and Marine

3,991
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay 4PDT (4 Form C) 0.5 Sec ~ 5 Sec 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
7024MEI1 TE Connectivity Aerospace, Defense and Marine

7024MEI1

RELAY TIME DELAY 200SEC 10A 240V

TE Connectivity Aerospace, Defense and Marine

2,746
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay 4PDT (4 Form C) 20 Sec ~ 200 Sec 10A @ 240VAC 28VDC Screw Terminal Hand Dial Input Voltage - -
7014MCI1 TE Connectivity Aerospace, Defense and Marine

7014MCI1

RELAY TIME DELAY 15SEC 10A 240V

TE Connectivity Aerospace, Defense and Marine

4,756
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay On-Delay 4PDT (4 Form C) 1.5 Sec ~ 15 Sec 10A @ 240VAC 28VDC Screw Terminal Hand Dial Input Voltage - -
5-1472973-0 TE Connectivity Aerospace, Defense and Marine

5-1472973-0

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

2,545
Datasheet - Bulk Active - - - - - - - - - - - -
7032CCB TE Connectivity Aerospace, Defense and Marine

7032CCB

RELAY TIME DELAY 15SEC 10A 400V

TE Connectivity Aerospace, Defense and Marine

1,455
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay, On-Delay DPDT (2 Form C) 1.5 Sec ~ 15 Sec 10A @ 240VAC 480VAC Screw Terminal Hand Dial Input Voltage - -
7012ODH2 TE Connectivity Aerospace, Defense and Marine

7012ODH2

RELAY TIME DELAY 50SEC 10A 240V

TE Connectivity Aerospace, Defense and Marine

2,641
Datasheet 7000, AGASTAT Bulk Active Through Hole Mechanical Relay On-Delay DPDT (2 Form C) 5 Sec ~ 50 Sec 10A @ 240VAC 24VDC PC Pin Hand Dial Input Voltage - -
1649335-1 TE Connectivity Aerospace, Defense and Marine

1649335-1

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

3,841
Datasheet - Bulk Obsolete - - - - - - - - - - - -
Total 5007 Record«Prev1... 239240241242243244245246...251Next»
FAQ

Frequently Asked Questions

What are Time Delay Relays components used for?

Time Delay Relays components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Time Delay Relays part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Time Delay Relays parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Time Delay Relays?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top