ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
FILTERED COMPONENT SELECTION

Time Delay Relays

Review Time Delay Relays Industrial Automation and Controls components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.

If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to ICMENU for sourcing and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Relay Type Function Circuit Delay Time Contact Rating @ Voltage Voltage - Supply Termination Style Timing Adjustment Method Timing Initiate Method Grade Qualification
9050JCK17V14 Schneider Electric

9050JCK17V14

RELAY TIME DELAY 30MIN 10A 240V

Schneider Electric

2,448
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay On-Delay DPDT (2 Form C) 0.3 Min ~ 30 Min 10A @ 240VAC 24VAC/DC Plug In Hand Dial Input Voltage - -
9050JCK16V14 Schneider Electric

9050JCK16V14

RELAY TIME DELAY 10MIN 10A 240V

Schneider Electric

4,661
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay On-Delay DPDT (2 Form C) 0.1 Min ~ 10 Min 10A @ 240VAC 24VAC/DC Plug In Hand Dial Input Voltage - -
9050JCK21V36 Schneider Electric

9050JCK21V36

RELAY TIME DELAY 10SEC 10A 240V

Schneider Electric

2,606
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay Off-Delay DPDT (2 Form C) 0.1 Sec ~ 10 Sec 10A @ 240VAC 12VAC/DC Plug In Hand Dial Input Voltage - -
9050JCK21V14 Schneider Electric

9050JCK21V14

RELAY TIME DELAY 10SEC 10A 240V

Schneider Electric

1,411
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay Off-Delay DPDT (2 Form C) 0.1 Sec ~ 10 Sec 10A @ 240VAC 24VAC/DC Plug In Hand Dial Input Voltage - -
9050JCK25V14 Schneider Electric

9050JCK25V14

RELAY TIME DELAY 180SEC 10A 240V

Schneider Electric

1,308
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay Off-Delay DPDT (2 Form C) 1.8 Sec ~ 180 Sec 10A @ 240VAC 24VAC/DC Plug In Hand Dial Input Voltage - -
9050JCK41V14 Schneider Electric

9050JCK41V14

RELAY TIME DELAY 10SEC 10A 240V

Schneider Electric

4,209
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay One Shot DPDT (2 Form C) 0.1 Sec ~ 10 Sec 10A @ 240VAC 24VAC/DC Plug In Hand Dial Input Voltage - -
9050JCK2F15V20 Schneider Electric

9050JCK2F15V20

RELAY TIME DELAY 15 SEC 10A 240V

Schneider Electric

1,566
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay Off-Delay DPDT (2 Form C) Fixed, 15 Sec 10A @ 240VAC 120VAC Plug In Fixed Input Voltage - -
9050JCK24V14 Schneider Electric

9050JCK24V14

RELAY TIME DELAY 120SEC 10A 240V

Schneider Electric

1,871
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay Off-Delay DPDT (2 Form C) 1.2 Sec ~ 120 Sec 10A @ 240VAC 24VAC/DC Plug In Hand Dial Input Voltage - -
9050JCK27V14 Schneider Electric

9050JCK27V14

RELAY TIME DELAY 30MIN 10A 240V

Schneider Electric

4,117
Datasheet Square D JCK Box Obsolete Socketable Mechanical Relay Off-Delay DPDT (2 Form C) 0.3 Min ~ 30 Min 10A @ 240VAC 24VAC/DC Plug In Hand Dial Input Voltage - -
821TD10HUNI Schneider Electric

821TD10HUNI

RELAY TIME DELAY 10HR DIN RAIL

Schneider Electric

2,332
Datasheet Legacy Box Obsolete DIN Rail Mechanical Relay Programmable (Multi-Function) SPDT (1 Form C) 0.1 Sec ~ 10 Hrs - 12 ~ 240VAC/DC Spring Terminal Screwdriver Slot Input Voltage - -
Total 162 Record«Prev1... 1011121314151617Next»
FAQ

Frequently Asked Questions

What are Time Delay Relays components used for?

Time Delay Relays components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Time Delay Relays part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Time Delay Relays parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Time Delay Relays Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top