ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Time Delay Relays

Explore Time Delay Relays parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Relay Type Function Circuit Delay Time Contact Rating @ Voltage Voltage - Supply Termination Style Timing Adjustment Method Timing Initiate Method Grade Qualification
8-1437449-6 TE Connectivity Aerospace, Defense and Marine

8-1437449-6

RELAY TIME DELAY 50SEC 10A 240V

TE Connectivity Aerospace, Defense and Marine

3,864
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay On-Delay 4PDT (4 Form C) 5 Sec ~ 50 Sec 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
7014PBL TE Connectivity Aerospace, Defense and Marine

7014PBL

RELAY TIME DELAY 5SEC 10A 240V

TE Connectivity Aerospace, Defense and Marine

4,897
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay On-Delay 4PDT (4 Form C) 0.7 Sec ~ 7 Sec 10A @ 240VAC 125VDC Screw Terminal Hand Dial Input Voltage - -
TR14I3B TE Connectivity Potter & Brumfield Relays

TR14I3B

RELAY TIME DELAY

TE Connectivity Potter & Brumfield Relays

3,895
Datasheet TR, AGASTAT Bulk Active Socketable Mechanical Relay On-Delay 4PDT (4 Form C) 0.55 Sec ~ 15 Sec 10A @ 120VAC 120VAC Plug In Screwdriver Slot Input Voltage - -
2-1423160-0 TE Connectivity Aerospace, Defense and Marine

2-1423160-0

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

3,786
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay On-Delay 4PDT (4 Form C) 0.7 Sec ~ 7 Sec 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
5-1423162-2 TE Connectivity Aerospace, Defense and Marine

5-1423162-2

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

2,242
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay DPDT (2 Form C) 3 Min ~ 30 Min 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
1-1423166-5 TE Connectivity Aerospace, Defense and Marine

1-1423166-5

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

2,855
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay 4PDT (4 Form C) 1.5 Sec ~ 15 Sec 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
TR14D3A TE Connectivity Potter & Brumfield Relays

TR14D3A

RELAY TIME DELAY

TE Connectivity Potter & Brumfield Relays

2,550
Datasheet TR, AGASTAT Bulk Active Socketable Mechanical Relay On-Delay 4PDT (4 Form C) 0.15 Sec ~ 3 Sec 10A @ 120VAC 215VDC Plug In Screwdriver Slot Input Voltage - -
6-1472973-8 TE Connectivity Aerospace, Defense and Marine

6-1472973-8

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

3,185
Datasheet - Bulk Active - - - - - - - - - - - -
7022RCA2I1 TE Connectivity Aerospace, Defense and Marine

7022RCA2I1

RELAY TIME DELAY 15SEC 10A 400V

TE Connectivity Aerospace, Defense and Marine

3,274
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay DPDT (2 Form C) 1.5 Sec ~ 15 Sec 10A @ 240VAC 60VDC Quick Connect Hand Dial Input Voltage - -
7022RFA2I TE Connectivity Aerospace, Defense and Marine

7022RFA2I

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

1,815
Datasheet - Bulk Active - - - - - - - - - - - -
TR14D3N TE Connectivity Potter & Brumfield Relays

TR14D3N

RELAY TIME DELAY 30MIN 10A 120V

TE Connectivity Potter & Brumfield Relays

2,255
Datasheet TR, AGASTAT Bulk Active Socketable Mechanical Relay On-Delay 4PDT (4 Form C) 1 Min ~ 30 Min 10A @ 120VAC 215VDC Plug In Screwdriver Slot Input Voltage - -
1-1423165-5 TE Connectivity Aerospace, Defense and Marine

1-1423165-5

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

4,832
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay Off-Delay 4PDT (4 Form C) 3 Cyc ~ 120 Cyc 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
2-1755142-9 TE Connectivity Aerospace, Defense and Marine

2-1755142-9

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

4,394
Datasheet - Bulk Active - - - - - - - - - - - -
2-1423158-0 TE Connectivity Aerospace, Defense and Marine

2-1423158-0

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

2,476
Datasheet - Bulk Active - - - - - - - - - - - -
2-1437488-8 TE Connectivity Aerospace, Defense and Marine

2-1437488-8

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

2,197
Datasheet - Bulk Active - - - - - - - - - - - -
2-1423163-4 TE Connectivity Aerospace, Defense and Marine

2-1423163-4

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

2,558
Datasheet - Bulk Active - - - - - - - - - - - -
2-1472973-4 TE Connectivity Aerospace, Defense and Marine

2-1472973-4

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

1,199
Datasheet 7000, AGASTAT Bulk Active Panel Mount Mechanical Relay On-Delay DPDT (2 Form C) 6 Min ~ 60 Min 10A @ 240VAC 120VAC Screw Terminal Hand Dial Input Voltage - -
1-1423158-8 TE Connectivity Aerospace, Defense and Marine

1-1423158-8

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

1,323
Datasheet - Bulk Active - - - - - - - - - - - -
1423328-6 TE Connectivity Aerospace, Defense and Marine

1423328-6

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

2,016
Datasheet - Bulk Active - - - - - - - - - - - -
7-1423157-0 TE Connectivity Aerospace, Defense and Marine

7-1423157-0

RELAY TIME DELAY

TE Connectivity Aerospace, Defense and Marine

1,113
Datasheet - Bulk Active - - - - - - - - - - - -
Total 5007 Record«Prev1... 204205206207208209210211...251Next»
FAQ

Frequently Asked Questions

What are Time Delay Relays components used for?

Time Delay Relays components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Time Delay Relays part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Time Delay Relays parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Time Delay Relays?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top