Time Delay Relays
Explore Time Delay Relays parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Relay Type | Function | Circuit | Delay Time | Contact Rating @ Voltage | Voltage - Supply | Termination Style | Timing Adjustment Method | Timing Initiate Method | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
H3CR-A-300 AC100-240/DC100-125RELAY TIME DELAY 300HR 5A 250V |
4,152 |
|
Datasheet | H3CR-A | Bulk | Obsolete | Socketable | Mechanical Relay | Programmable (Multi-Function) | DPDT (2 Form C) | 0.05 Sec ~ 300 Hrs | 5A @ 250VAC | 100 ~ 240VAC, 100 ~ 125VDC | Plug In, 11 Pin (Octal) | Hand Dial | - | - | - |
|
H3DE-M2 DC12RELAY TIME DELAY 120HR 5A 250V |
2,909 |
|
Datasheet | H3DE-M | Bulk | Obsolete | DIN Rail | Mechanical Relay | Programmable (Multi-Function) | DPDT (2 Form C) | 0.1 Sec ~ 120 Hrs | 5A @ 250VAC | 12VDC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
PRS65RELAY TIME DELAY 480SEC 10A 400V |
1,091 |
|
Datasheet | PRS | Bulk | Active | Socketable | Mechanical Relay | One Shot | SPDT (1 Form C) | 7 Sec ~ 480 Sec | 10A @ 400VAC | 230VAC | Plug In, 8 Pin (Octal) | Hand Dial | Input Voltage | - | - |
|
2867924RELAY TIME DELAY 3MIN 5A 250V |
3,726 |
|
Datasheet | ETD-SL-1T | Bulk | Obsolete | DIN Rail | Mechanical Relay | Star Delta Controller | DPDT (2 Form C) | 0.5 Sec ~ 3 Min | 5A @ 250VAC | 24 ~ 230VAC, 24VDC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
H3DE-F AC/DC24-230RELAY TIME DELAY 12HR 5A 250V |
2,358 |
|
Datasheet | H3DE-F | Bulk | Obsolete | DIN Rail | Mechanical Relay | Repeat Cycle, Twin Timer | SPDT (1 Form C) | 0.1 Sec ~ 12 Hrs | 5A @ 250VAC | 24 ~ 230VAC/DC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
H3DE-G AC/DC24-230RELAY TIME DELAY 120 SEC 5A 250V |
3,614 |
|
Datasheet | H3DE-G | Bulk | Obsolete | DIN Rail | Mechanical Relay | Star Delta Controller | DPDT (2 Form C) | 1 Sec ~ 120 Sec | 5A @ 250VAC | 24 ~ 230VAC/DC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
H3DE-H AC/DC24 LRELAY TIME DELAY 120 SEC 5A 250V |
1,995 |
|
Datasheet | H3DE-H | Bulk | Obsolete | DIN Rail | Mechanical Relay | Off-Delay | SPDT (1 Form C) | 1 Sec ~ 120 Sec | 5A @ 250VAC | 24VAC/DC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
GT3S-1AF20RELAY TIME DELAY 100SEC 5A 250V |
2,133 |
|
Datasheet | GT3 | Bulk | Active | Socketable | Mechanical Relay | Star Delta Controller | SPST-NO (1 Form A) | 0.05 Sec ~ 100 Sec | 5A @ 250VAC/30VDC | 100 ~ 240VAC | Plug In, 8 Pin (Octal) | Hand Dial | Input Voltage | - | - |
|
PRLM423RELAY TIME DELAY 60SEC 10A 240V |
3,681 |
|
Datasheet | PRLM | Bulk | Active | Socketable | Mechanical Relay | On-Delay | DPDT (2 Form C) | 1 Sec ~ 60 Sec | 10A @ 240VAC | 120VAC | Plug In, 8 Pin (Octal) | Fixed | Input Voltage | - | - |
|
H3Y-4 DC24 10MRELAY TIME DELAY 10MIN 3A 250V |
3,006 |
|
Datasheet | H3Y | Bulk | Active | Socketable | Mechanical Relay | Off-Delay, On-Delay | 4PDT (4 Form C) | 0.5 Min ~ 10 Min | 3A @ 250VAC | 24VDC | Plug In | Hand Dial | Input Voltage | - | - |
|
H3Y-4 AC200-230 5SRELAY TIME DELAY 5SEC 3A 250V |
2,989 |
|
Datasheet | H3Y | Bulk | Active | Socketable | Mechanical Relay | Off-Delay, On-Delay | 4PDT (4 Form C) | 0.2 Sec ~ 5 Sec | 3A @ 250VAC | 200 ~ 230VAC | Plug In | Hand Dial | Input Voltage | - | - |
|
H3Y-4-B AC100-120 10SRELAY TIME DELAY 10SEC |
4,925 |
|
Datasheet | H3Y | Bulk | Active | DIN Rail | Mechanical Relay | On-Delay | 4PDT (4 Form C) | 0.5 Sec ~ 10 Sec | 5A @ 250VAC | 100 ~ 120VAC | Spring Terminal | Hand Dial | Input Voltage | - | - |
|
H3Y-4-B AC100-120 5SRELAY TIME DELAY 5SEC |
2,662 |
|
Datasheet | H3Y | Bulk | Active | DIN Rail | Mechanical Relay | On-Delay | 4PDT (4 Form C) | 0.2 Sec ~ 5 Sec | 5A @ 250VAC | 100 ~ 120VAC | Spring Terminal | Hand Dial | Input Voltage | - | - |
|
H3Y-4-B AC100-120 60SRELAY TIME DELAY 60SEC |
1,533 |
|
Datasheet | H3Y | Bulk | Active | DIN Rail | Mechanical Relay | On-Delay | 4PDT (4 Form C) | 2 Sec ~ 60 Sec | 5A @ 250VAC | 100 ~ 120VAC | Spring Terminal | Hand Dial | Input Voltage | - | - |
|
H3Y-4-B AC100-120 10MRELAY TIME DELAY 10MIN |
2,680 |
|
Datasheet | H3Y | Bulk | Active | DIN Rail | Mechanical Relay | On-Delay | 4PDT (4 Form C) | 0.5 Min ~ 10 Min | 5A @ 250VAC | 100 ~ 120VAC | Spring Terminal | Hand Dial | Input Voltage | - | - |
|
H3Y-4-B AC100-120 1SRELAY TIME DELAY 1SEC |
3,801 |
|
Datasheet | H3Y | Bulk | Active | DIN Rail | Mechanical Relay | On-Delay | 4PDT (4 Form C) | 0.1 Sec ~ 1 Sec | 5A @ 250VAC | 100 ~ 120VAC | Spring Terminal | Hand Dial | Input Voltage | - | - |
|
DBB51CM241MRELAY TIME DELAY 60SEC 5A 250V |
1,966 |
|
Datasheet | DBB51 | Box | Active | DIN Rail | Mechanical Relay | Off-Delay | SPDT (1 Form C) | 6 Sec ~ 60 Sec | 5A @ 250VAC | 24 ~ 240VAC, 24VDC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
H3DK-S2A DC12RELAY TIME DELAY 1200HR 5A 250V |
1,428 |
|
Datasheet | H3DK-S | Bulk | Active | DIN Rail | Mechanical Relay | Programmable (Multi-Function) | DPDT (2 Form C) | 0.1 Sec ~ 1200 Hrs | 5A @ 250VAC | 12VDC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
|
8243770000RELAY TIME DELAY 1SEC 0.1A 48V |
4,243 |
|
Datasheet | DKZA | Bulk | Obsolete | DIN Rail | Solid State Relay | Off-Delay | SPST-NO (1 Form A) | 0.1 Sec ~ 1 Sec | 0.1A @ 48VDC | 24VDC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
TDM24DLRELAY TIME DEL 1023SEC 10A 120V |
3,930 |
|
Datasheet | TDM | Bulk | Active | Socketable | Mechanical Relay | On-Delay | DPDT (2 Form C) | 1 Sec ~ 1023 Sec | 10A @ 120/240VAC | 24 ~ 28VDC | Plug In, 8 Pin (Octal) | DIP Switches | Input Voltage | - | - |
Frequently Asked Questions
What are Time Delay Relays components used for?
Time Delay Relays components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Time Delay Relays part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Time Delay Relays parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.