Time Delay Relays
Explore Time Delay Relays parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Relay Type | Function | Circuit | Delay Time | Contact Rating @ Voltage | Voltage - Supply | Termination Style | Timing Adjustment Method | Timing Initiate Method | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ORB24A11DRELAY TIME DELAY 1 SEC 10A 120V |
2,798 |
|
Datasheet | ORB | Bulk | Active | Chassis Mount | Mechanical Relay | Off-Delay | DPDT (2 Form C) | Fixed, 1 Sec | 10A @ 120/240VAC | 24VAC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
|
ORB24A21DRELAY TIME DELAY 3SEC 10A 120V |
2,610 |
|
Datasheet | ORB | Bulk | Active | Chassis Mount | Mechanical Relay | Off-Delay | DPDT (2 Form C) | 0.05 Sec ~ 3 Sec | 10A @ 120/240VAC | 24VAC | Quick Connect - 0.250" (6.3mm) | Screwdriver Slot | Input Voltage, Trigger Signal | - | - |
|
ORB24A25RELAY TIME DELAY 300SEC 10A 120V |
3,656 |
|
Datasheet | ORB | Bulk | Active | Chassis Mount | Mechanical Relay | Off-Delay | SPDT (1 Form C) | 3 Sec ~ 300 Sec | 10A @ 120/240VAC | 24VAC | Quick Connect - 0.250" (6.3mm) | Screwdriver Slot | Input Voltage, Trigger Signal | - | - |
|
ORS120A150SDRELAY TIME DELAY 50SEC 10A 120V |
1,451 |
|
Datasheet | ORS | Bulk | Active | Chassis Mount | Mechanical Relay | One Shot | DPDT (2 Form C) | Fixed, 50 Sec | 10A @ 120/240VAC | 120VAC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage | - | - |
|
48636RELAY TIME DELAY 10A 24V CHAS MT |
3,286 |
|
Datasheet | - | Bulk | Obsolete | Chassis Mount | Solid State Relay | Programmable (Multi-Function) | - | - | 10A @ 24VDC | 9 ~ 32VDC | Connector | - | Input Voltage | - | - |
|
H3Y-4 AC24 30SRELAY TIME DELAY 30SEC |
3,080 |
|
Datasheet | H3Y | Bulk | Active | Socketable | Mechanical Relay | Off-Delay, On-Delay | 4PDT (4 Form C) | 1 Sec ~ 30 Sec | 3A @ 250VAC | 24VAC | Plug In | Hand Dial | Input Voltage | - | - |
|
15954.2RELAY TIME DELAY DIN RAIL |
4,542 |
|
Datasheet | - | Box | Active | DIN Rail | - | - | SPST-NO (1 Form A) | - | - | 24VDC | Plug In | - | - | - | - |
|
E1ZI10 12-240VAC/DCRELAY TIME DELAY 100HR 8A 250V |
3,558 |
|
Datasheet | ENYA | Bulk | Active | DIN Rail | Mechanical Relay | Repeat Cycle | SPDT (1 Form C) | 0.05 Sec ~ 100 Hrs | 8A @ 250VAC | 12 ~ 240VAC/DC | Screw Terminal | Screwdriver Slot | Input Voltage, Trigger Signal | - | - |
|
KSDR40A0RELAY TIME DELAY 10SEC CHAS MT |
4,470 |
|
Datasheet | KSDR | Bulk | Active | Chassis Mount | Solid State Relay | Repeat Cycle | SPST-NO (1 Form A) | 0.1 Sec ~ 10 Sec | - | 120VAC | Quick Connect - 0.250" (6.3mm) | Screwdriver Slot | Input Voltage | - | - |
|
81.01.0.230.0000RELAY TIME DELAY 10HR 16A 250V |
3,727 |
|
Datasheet | 81 | Box | Active | DIN Rail | Mechanical Relay | Programmable (Multi-Function) | SPDT (1 Form C) | 0.1 Sec ~ 10 Hrs | 16A @ 250VAC | 12 ~ 230VAC | Screw Terminal | Screwdriver Slot | Input Voltage | - | - |
|
HRDS430RELAY TIME DELAY 10SEC 30A 125V |
4,223 |
|
Datasheet | HRDS | Bulk | Obsolete | Chassis Mount | Mechanical Relay | One Shot | SPDT (1 Form C) | 0.1 Sec ~ 10 Sec | 30A @ 125/240VAC | 120VAC | Quick Connect - 0.250" (6.3mm) | External Resistor | Input Voltage, Trigger Signal | - | - |
|
RTE-B1D12RELAY TIME DELAY 600HR 10A 240V |
4,935 |
|
Datasheet | RTE | Bulk | Active | Socketable | Mechanical Relay | Programmable (Multi-Function) | DPDT (2 Form C) | 0.1 Sec ~ 600 Hrs | 10A @ 240VAC/30VDC | 12VDC | Plug In, 11 Pin | Hand Dial | Input Voltage | - | - |
|
ERDM429RELAY TIME DELAY 15MIN 10A 120V |
3,005 |
|
Datasheet | ERDM | Bulk | Obsolete | Chassis Mount | Mechanical Relay | On-Delay | DPDT (2 Form C) | 0.2 Min ~ 15 Min | 10A @ 120/240VAC | 120VAC | Quick Connect - 0.250" (6.3mm) | Hand Dial | Input Voltage | - | - |
|
KRD9120BRELAY TIME DELAY 10SEC 10A 125V |
3,223 |
|
Datasheet | KRD9 | Bulk | Active | Chassis Mount | Mechanical Relay | One Shot | SPDT (1 Form C) | 0.1 Sec ~ 10 Sec | 10A @ 125VAC | 12VDC | Quick Connect - 0.250" (6.3mm) | Screwdriver Slot | Input Voltage, Trigger Signal | - | - |
|
KRD92115MBRELAY TIME DELAY 15 MIN 10A 125V |
2,101 |
|
Datasheet | KRD9 | Bulk | Active | Chassis Mount | Mechanical Relay | One Shot | SPDT (1 Form C) | Fixed, 15 Min | 10A @ 125VAC | 24VAC/DC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
|
KRD93115MARELAY TIME DELAY 15 MIN 10A 125V |
3,837 |
|
Datasheet | KRD9 | Bulk | Active | Chassis Mount | Mechanical Relay | One Shot | SPDT (1 Form C) | Fixed, 15 Min | 10A @ 125VAC | 24VDC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
|
KRDB110.1SRELAY TIME DELAY 0.1SEC 10A 125V |
3,880 |
|
Datasheet | KRDB | Bulk | Active | Chassis Mount | Mechanical Relay | Off-Delay | SPDT (1 Form C) | Fixed, 0.1 Sec | 10A @ 125VAC | 12VDC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
|
KRDB115MRELAY TIME DELAY 5MIN 10A 125V |
2,891 |
|
Datasheet | KRDB | Bulk | Active | Chassis Mount | Mechanical Relay | Off-Delay | SPDT (1 Form C) | Fixed, 5 Min | 10A @ 125VAC | 12VDC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
|
KRDB217SRELAY TIME DELAY 7SEC 10A 125V |
1,814 |
|
Datasheet | KRDB | Bulk | Active | Chassis Mount | Mechanical Relay | Off-Delay | SPDT (1 Form C) | Fixed, 7 Sec | 10A @ 125VAC | 24VAC/DC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
|
KRDB31120SRELAY TIME DELAY 20 SEC 10A 125V |
3,399 |
|
Datasheet | KRDB | Bulk | Active | Chassis Mount | Mechanical Relay | Off-Delay | SPDT (1 Form C) | Fixed, 20 Sec | 10A @ 125VAC | 24VDC | Quick Connect - 0.250" (6.3mm) | Fixed | Input Voltage, Trigger Signal | - | - |
Frequently Asked Questions
What are Time Delay Relays components used for?
Time Delay Relays components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Time Delay Relays part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Time Delay Relays parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.