Liquid Cooling, Heating
Explore Liquid Cooling, Heating parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Product Type | Power - Cooling | Current | Voltage | Flow Rate | Power Input | Thermal Resistance @ GPM | Fluid Capacity | Operating Temperature | Connection Type | Weight | Dimensions - Overall | Ratings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
6340G2-M9HEAT EXCHANGER |
1,698 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
387002779.03HEAT EXCHANGE LIQUID - AIR 3000W |
1,707 |
|
Datasheet | WL | Bulk | Active | Active, Recirculating Chiller | 3000 W | 2.5 A | 230VAC | 1.59GPM (6.0LPM) | - | - | 3700ML (125.1 oz) | 5°C ~ 40°C | 9mm Press Fit | - | 17.48" L x 15.67" W x 18.94" H (444.0mm x 398.0mm x 481.0mm) | - |
|
HPLC-RM-200RACK MOUNT CHILLER 200W |
2,441 |
|
Datasheet | HPLC-RM | Box | Active | Active, Recirculating Chiller | 200 W | - | 100 ~ 240VAC | - | - | - | - | 10°C ~ 35°C | - | - | 19.06" L x 13.54" W x 6.93" H (484.0mm x 344.0mm x 176.0mm) | CE, UL |
|
ATS-CHILL2300VVAPOR COMPRESSION BASED WATER CH |
2,085 |
|
Datasheet | * | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
9620100.02F1000 CHILLER, 1KW, 115V |
3,275 |
|
Datasheet | F | Bulk | Active | Active, Recirculating Chiller | 1000 W | 11 A | 115VAC | 6.08GPM (23.0LPM) | - | - | - | -0°C ~ 40°C | - | 99 lbs (44.9 kg) | 19.30" L x 14.80" W x 25.20" H (490.2mm x 375.9mm x 640.1mm) | - |
|
ATS-TECHILL-1400ATHERMOELECTRIC (TEC) BASED CHILL |
3,351 |
|
Datasheet | TECHILL | Box | Active | Active, Recirculating Chiller/Heater | 1.4 kW | 20 A | 180 ~ 264VAC | 1GPM (3.79LPM) | - | - | - | 5°C ~ 50°C | - | - | 15.70" L x 28.40" W x 26.60" H (398.8mm x 721.4mm x 675.6mm) | - |
|
385912-029NRC5000-A1-20-ST1 |
1,933 |
|
Datasheet | Nextreme™ | Box | Obsolete | Active, Recirculating Chiller | 5000 W | - | 200 ~ 240V | 3.96GPM (15.0LPM) | - | - | 5000ML (169.1 oz) | 15°C ~ 40°C | - | 220 lbs (99.8 kg) | 24.90" L x 23.00" W x 31.90" H (632.0mm x 583.0mm x 809.0mm) | CE, UL |
|
9663012.13FL1203 CHILLER, 1.2KW, 230V/60Hz |
2,609 |
|
Datasheet | FL | Bulk | Active | Active, Recirculating Chiller | 1200 W | 11 A | 230VAC | 10.57GPM (40.0LPM) | - | - | - | -20°C ~ 40°C | - | 161 lbs (73.0 kg) | 29.90" L x 19.70" W x 25.20" H (759.5mm x 500.4mm x 640.1mm) | - |
|
9663040.16FL4003 CHILLER, 4KW, 230V/3PPE |
2,247 |
|
Datasheet | FL | Bulk | Active | Active, Recirculating Chiller | 4000 W | - | 230 ~ 400VAC | 10.57GPM (40.0LPM) | - | - | - | -20°C ~ 40°C | - | 326 lbs (148.0 kg) | 29.90" L x 23.60" W x 47.24" H (759.5mm x 599.4mm x 1200.0mm) | - |
|
9666110.16FL11006 CHILLER, 11KW, 230V/3PPE |
2,407 |
|
Datasheet | - | Bulk | Active | Active, Recirculating Chiller | 10300 W | - | 230 ~ 400VAC | 15.85GPM (60.0LPM) | - | - | - | -20°C ~ 40°C | - | 556 lbs (252.2 kg) | 33.50" L x 30.70" W x 59.06" H (850.9mm x 779.8mm x 1500.0mm) | - |
|
|
9666070.16.CSA/ULFL7006 NRTL 230V/3PPE/60hz |
4,296 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
9666200.16FL20006 CHILLER, 20KW, 230V/3PPE |
1,258 |
|
Datasheet | FL | Bulk | Active | Active, Recirculating Chiller/Heater | 20000 W | - | 230 ~ 400VAC | 21.13GPM (80.0LPM) | - | - | - | -25°C ~ 40°C | - | 827 lbs (375.1 kg) | 47.24" L x 37.40" W x 62.99" H (1200.0mm x 950.0mm x 1600.0mm) | - |
|
9421552.16PRESTO W55, Water-Cooled REFRIGE |
4,403 |
|
Datasheet | PRESTO W55 | Bulk | Active | Active, Recirculating Chiller/Heater | 13500 W | - | 208 ~ 400VAC | 9.25GPM-21.13GPM (35.0LPM-80.0LPM) | - | - | - | -55°C ~ 250°C | - | 635 lbs (288.0 kg) | 33.30" L x 24.00" W x 49.21" H (845.8mm x 609.6mm x 1250.0mm) | - |
|
9421562.17PRESTO W56, Water-Cooled refrige |
1,243 |
|
Datasheet | PRESTO W56 | Bulk | Active | Active, Recirculating Chiller/Heater | 25800 W | - | 400 ~ 480VAC | 9.25GPM-21.13GPM (35.0LPM-80.0LPM) | - | - | - | -56°C ~ 250°C | - | 849 lbs (385.1 kg) | 37.00" L x 23.60" W x 62.99" H (939.8mm x 599.4mm x 1600.0mm) | - |
|
|
1530.01HEAT EXCHANGER 230V 6LPM 3000W |
2,104 |
|
Datasheet | WL | Box | Obsolete | Active, Heat Exchanger | 3000 W | 2.5 A | 230VAC | 1.59GPM (6.0LPM) | - | - | 3700ML (125.1 oz) | 5°C ~ 40°C | 9mm Press Fit | 85 lbs (38.6 kg) | 18.86" L x 15.67" W x 18.94" H (479.0mm x 398.0mm x 481.0mm) | - |
|
|
1550.00HEAT EXCHANGER 230V 6.5LPM 5000W |
3,266 |
|
Datasheet | WL | Box | Obsolete | Active, Heat Exchanger | 5000 W | 2.6 A | 230VAC | 1.72GPM (6.5LPM) | - | - | 5000ML (169.1 oz) | 5°C ~ 40°C | 9mm Press Fit | 85 lbs (38.6 kg) | 19.02" L x 15.98" W x 18.94" H (483.0mm x 406.0mm x 481.0mm) | - |
|
16-60-002-01SPACER BLOCK/PLATE |
1,017 |
|
Datasheet | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
16-60-003-01SPACER BLOCK/PLATE |
2,287 |
|
Datasheet | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
16-60-005-01SPACER BLOCK/PLATE |
3,384 |
|
Datasheet | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
520019-01PELTIER |
1,061 |
|
Datasheet | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Liquid Cooling, Heating components used for?
Liquid Cooling, Heating components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Liquid Cooling, Heating part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Liquid Cooling, Heating parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.