ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
FILTERED COMPONENT SELECTION

Preparation-Treatment

Review Preparation-Treatment Industrial Automation and Controls components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.

If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to ICMENU for sourcing and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Operating Pressure Pressure Regulation Flow Rate Features Connection Method Filtration Level Fluid Type Operating Temperature Flow Direction Drain Type Condensation Capacity Oil Capacity
MS6-LFR-1/2-D7-CUV-AS Festo Corporation

MS6-LFR-1/2-D7-CUV-AS

FILTER REGULATOR

Festo Corporation

2,573
Datasheet MS Bulk Active Filter Regulator 29 ~ 174 PSI (2 ~ 12 bar) 7.3 ~ 174 PSI (0.5 ~ 12 bar) 1057GPM (4000LPM) - G1/2 5µm Compressed Air, Inert Gas 5°C ~ 60°C Left to Right Automatic 1.29oz (38ml) -
MS6-LFM-1/2-AUV Festo Corporation

MS6-LFM-1/2-AUV

MICRO FILTER

Festo Corporation

1,341
Datasheet MS Bulk Active Filter 29 ~ 174 PSI (2 ~ 12 bar) - 238GPM (900LPM) - G1/2 0.01µm Compressed Air, Inert Gas 5°C ~ 60°C Left to Right Automatic 1.29oz (38ml) -
MS6-LRP-1/4-D5-A8 Festo Corporation

MS6-LRP-1/4-D5-A8

PRECISION PRESSURE REGULATOR

Festo Corporation

1,180
Datasheet MS Bulk Active Regulator 14.5 ~ 203 PSI (1 ~ 14 bar) 1.5 ~ 58 PSI (0.1 ~ 4 bar) 370GPM (1400LPM) - G1/4 - Compressed Air, Inert Gas -10°C ~ 60°C Left to Right - - -
MS6-LRP-1/2-D4-A8 Festo Corporation

MS6-LRP-1/2-D4-A8

PRECISION PRESSURE REGULATOR

Festo Corporation

3,597
Datasheet MS Bulk Active Regulator 14.5 ~ 203 PSI (1 ~ 14 bar) 0.7 ~ 36 PSI (0.05 ~ 2.5 bar) 608GPM (2300LPM) - G1/2 - Compressed Air, Inert Gas -10°C ~ 60°C Left to Right - - -
MS4-LFR-1/4-D6-EPM-AG-BAR-B Festo Corporation

MS4-LFR-1/4-D6-EPM-AG-BAR-B

FILTER REGULATOR

Festo Corporation

2,880
Datasheet MS Bulk Active Filter Regulator 14.5 ~ 145 PSI (1 ~ 10 bar) 4.4 ~ 102 PSI (0.3 ~ 7 bar) 374GPM (1700LPM) Pressure Gauge G1/4 40µm Compressed Air, Inert Gas -5°C ~ 50°C Left to Right Manual 0.56oz (16.5ml) -
MS4-LFR-1/4-D6-CPM-AG-BAR-B Festo Corporation

MS4-LFR-1/4-D6-CPM-AG-BAR-B

FILTER REGULATOR

Festo Corporation

4,402
Datasheet MS Bulk Active Filter Regulator 14.5 ~ 145 PSI (1 ~ 10 bar) 4.4 ~ 102 PSI (0.3 ~ 7 bar) 396GPM (1500LPM) Pressure Gauge G1/4 5µm Compressed Air, Inert Gas -5°C ~ 50°C Left to Right Manual 0.56oz (16.5ml) -
MS6-LR-1/2-D6-AG-BAR-B Festo Corporation

MS6-LR-1/2-D6-AG-BAR-B

PRESSURE REGULATOR

Festo Corporation

1,520
Datasheet MS Bulk Active Regulator 14.5 ~ 145 PSI (1 ~ 10 bar) 4.4 ~ 102 PSI (0.3 ~ 7 bar) 1585GPM (6000LPM) Pressure Gauge G1/2 - Compressed Air, Inert Gas -5°C ~ 50°C Left to Right - - -
MS6-LFR-1/2-D6-EPM-AG-BAR-B Festo Corporation

MS6-LFR-1/2-D6-EPM-AG-BAR-B

FILTER REGULATOR

Festo Corporation

4,889
Datasheet MS Bulk Active Filter Regulator 29 ~ 145 PSI (2 ~ 10 bar) 4.4 ~ 102 PSI (0.3 ~ 7 bar) 1400GPM (5300LPM) - G1/2 40µm Compressed Air, Inert Gas -10°C ~ 60°C Left to Right Manual - -
MS4-LFR-1/4-D6-EPV-AG-BAR-B Festo Corporation

MS4-LFR-1/4-D6-EPV-AG-BAR-B

FILTER REGULATOR

Festo Corporation

2,553
Datasheet MS Bulk Active Filter Regulator 14.5 ~ 145 PSI (1 ~ 10 bar) 4.4 ~ 102 PSI (0.3 ~ 7 bar) 449GPM (1700LPM) - G1/4 40µm Compressed Air, Inert Gas -10°C ~ 60°C Left to Right Manual - -
MS4-LFR-1/4-D6-CPV-AG-BAR-B Festo Corporation

MS4-LFR-1/4-D6-CPV-AG-BAR-B

FILTER REGULATOR

Festo Corporation

1,036
Datasheet MS Bulk Active Filter Regulator 14.5 ~ 145 PSI (1 ~ 10 bar) 4.4 ~ 102 PSI (0.3 ~ 7 bar) 449GPM (1700LPM) - G1/4 5µm Compressed Air, Inert Gas -10°C ~ 60°C Left to Right Automatic - -
Total 2806 Record«Prev12345678910...281Next»
FAQ

Frequently Asked Questions

What are Preparation-Treatment components used for?

Preparation-Treatment components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Preparation-Treatment part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Preparation-Treatment parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Preparation-Treatment Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top