Preparation-Treatment
Explore Preparation-Treatment parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Operating Pressure | Pressure Regulation | Flow Rate | Features | Connection Method | Filtration Level | Fluid Type | Operating Temperature | Flow Direction | Drain Type | Condensation Capacity | Oil Capacity |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MPPE-3-1/2-6-010-BPROPORTIONAL-PRESSURE REGULATOR |
3,232 |
|
Datasheet | MPPE | Bulk | Active | Regulator | 116 PSI (8 bar) | 0 ~ 87 PSI (0 ~ 6 bar) | - | 18 ~ 30VDC Supply Voltage | G1/2 | - | Compressed Air, Inert Gas | 0°C ~ 50°C | - | - | - | - |
|
MPPE-3-1/2-2,5-420-BPROPORTIONAL-PRESSURE REGULATOR |
3,571 |
|
Datasheet | MPPE | Bulk | Active | Regulator | 65 PSI (4.5 bar) | 0 ~ 36 PSI (0 ~ 2.5 bar) | - | 18 ~ 30VDC Supply Voltage | G1/2 | - | Compressed Air, Inert Gas | 0°C ~ 50°C | - | - | - | - |
|
MPPE-3-1/2-6-420-BPROPORTIONAL-PRESSURE REGULATOR |
3,159 |
|
Datasheet | MPPE | Bulk | Active | Regulator | 116 PSI (8 bar) | 0 ~ 87 PSI (0 ~ 6 bar) | - | 18 ~ 30VDC Supply Voltage | G1/2 | - | Compressed Air, Inert Gas | 0°C ~ 50°C | - | - | - | - |
|
MPPE-3-1/2-10-010-BPROPORTIONAL-PRESSURE REGULATOR |
4,084 |
|
Datasheet | MPPE | Bulk | Active | Regulator | 177PSI (12 bar) | 0 ~ 145 PSI (0 ~ 10 bar) | - | 18 ~ 30VDC Supply Voltage | G1/2 | - | Compressed Air, Inert Gas | 0°C ~ 50°C | - | - | - | - |
|
MPPE-3-1/2- -BPROPORTIONAL-PRESSURE REGULATOR |
1,942 |
|
Datasheet | MPPE | Bulk | Active | Regulator | 0 ~ 145 PSI (0 ~ 10 bar) | 0 ~ 145 PSI (0 ~ 10 bar) | - | 18 ~ 30VDC Supply Voltage | G1/2 | - | Compressed Air, Inert Gas | 0°C ~ 50°C | - | - | - | - |
|
MSE6-C2M-5000-FB44-D-RG-BAR-AMI-AGDENERGY EFFICIENCY MODULE |
4,459 |
|
Datasheet | MSE6 | Bulk | Active | Regulator | 50 ~ 188 PSI (3.5 ~ 13 bar) | - | - | Pressure Gauge | G1/2 | - | Compressed Air | 0°C ~ 50°C | - | Automatic | - | - |
|
LDM1-3/4-D-MAXI-300MEMBRANE AIR DRYER |
3,468 |
|
Datasheet | D | Bulk | Obsolete | Filter | 43.5 ~ 181.3 PSI (3 ~ 12.5 bar) | - | 79GPM (300LPM) | - | G3/4 | - | Compressed Air | 2°C ~ 50°C | - | - | - | - |
|
MSE6-C2M-5000-FB43-D-M-RG-BAR-M12L4-MQ1-AGDENERGY EFFICIENCY MODULE |
2,967 |
|
Datasheet | MSE6 | Bulk | Active | Filter Regulator | 72.5 ~ 159.5 PSI (5 ~ 11 bar) | 36 ~ 145 PSI (2.5 ~ 10 bar) | 1849GPM (7000LPM) | - | G1/2 | - | Compressed Air | 0°C ~ 50°C | Left to Right | Automatic | - | - |
|
MSE6-C2M-5000-FB43-D-M-RG-BAR-M12L5-MQ1-AGDENERGY EFFICIENCY MODULE |
3,429 |
|
Datasheet | MSE6 | Bulk | Active | Filter Regulator | 72.5 ~ 159.5 PSI (5 ~ 11 bar) | 36 ~ 145 PSI (2.5 ~ 10 bar) | 1849GPM (7000LPM) | - | G1/2 | - | Compressed Air | 0°C ~ 50°C | Left to Right | Automatic | - | - |
|
MSE6-C2M-5000-FB44-D-M-RG-BAR-AMI-AGDENERGY EFFICIENCY MODULE |
3,243 |
|
Datasheet | MSE6 | Bulk | Active | Regulator | 188 PSI (13 bar) | - | - | Pressure Gauge | G1/2 | - | Compressed Air | 0°C ~ 50°C | - | Automatic | - | - |
|
MSE6-C2M-5000-FB36-D-M-RG-BAR-M12L5-AGDENERGY EFFICIENCY MODULE |
4,930 |
|
Datasheet | MSE6 | Bulk | Active | Filter Regulator | 72.5 ~ 159.5 PSI (5 ~ 11 bar) | 36 ~ 145 PSI (2.5 ~ 10 bar) | 1849GPM (7000LPM) | 18 ~ 30VDC Supply Voltage | G1/2 | - | Compressed Air | 0°C ~ 50°C | - | Automatic | - | - |
|
MSE6-C2M-5000-FB36-D-M-RG-BAR-M12L4-AGDENERGY EFFICIENCY MODULE |
1,923 |
|
Datasheet | MSE6 | Bulk | Active | Filter Regulator | 72.5 ~ 159.5 PSI (5 ~ 11 bar) | 36 ~ 145 PSI (2.5 ~ 10 bar) | 1849GPM (7000LPM) | 18 ~ 30VDC Supply Voltage | G1/2 | - | Compressed Air | 0°C ~ 50°C | - | Automatic | - | - |
|
MSE6-D2M-5000-CBUS-S-RG-BAR-VCB-AGDENERGY EFFICIENCY MODULE |
1,825 |
|
Datasheet | MSE6 | Bulk | Active | Regulator | 50 ~ 145 PSI (3.5 ~ 10 bar) | 50 ~ 145 PSI (3.5 ~ 10 bar) | 1189GPM (4500LPM) | - | Push-In Connection for Tubing 6.00mm Dia | - | Compressed Air | 0°C ~ 50°C | Left to Right | Automatic | - | - |
|
VPPL-3L-3-G14-0L20H-A4-A-S1-6PROPORTIONAL-PRESSURE REGULATOR |
2,358 |
|
Datasheet | VPPL | Bulk | Active | Regulator | 290 PSI (20 bar) | 2.9 ~ 290 PSI (0.2 ~ 20 bar) | 74GPM (282LPM) | 24VDC Supply Voltage | G1/4 | - | Compressed Air, Inert Gas | 5°C ~ 50°C | - | - | - | - |
|
VPPL-3L-3-G14-0L40H-V1-V-S1-7PROPORTIONAL-PRESSURE REGULATOR |
1,313 |
|
Datasheet | VPPL | Bulk | Active | Regulator | 725 PSI (50 bar) | 2.9 ~ 580 PSI (0.2 ~ 40 bar) | 74GPM (282LPM) | 24VDC Supply Voltage | G1/4 | - | Compressed Air, Inert Gas | 5°C ~ 50°C | - | - | - | - |
|
VPPL-3L-3-G14-0L20H-V1-A-S1-6PROPORTIONAL-PRESSURE REGULATOR |
2,491 |
|
Datasheet | VPPL | Bulk | Active | Regulator | 290 PSI (20 bar) | 2.9 ~ 290 PSI (0.2 ~ 20 bar) | 74GPM (282LPM) | 24VDC Supply Voltage | G1/4 | - | Compressed Air, Inert Gas | 5°C ~ 50°C | - | - | - | - |
|
VPPL-3L-3-G14-0L40H-A4-A-S1-7PROPORTIONAL-PRESSURE REGULATOR |
3,520 |
|
Datasheet | VPPL | Bulk | Active | Regulator | 725 PSI (50 bar) | 2.9 ~ 580 PSI (0.2 ~ 40 bar) | 74GPM (282LPM) | 24VDC Supply Voltage | G1/4 | - | Compressed Air, Inert Gas | 5°C ~ 50°C | - | - | - | - |
|
VPPL-3L-3-G14-0L40H-V1-A-S1-7PROPORTIONAL-PRESSURE REGULATOR |
1,124 |
|
Datasheet | VPPL | Bulk | Active | Regulator | 725 PSI (50 bar) | 2.9 ~ 580 PSI (0.2 ~ 40 bar) | 74GPM (282LPM) | 24VDC Supply Voltage | G1/4 | - | Compressed Air, Inert Gas | 5°C ~ 50°C | - | - | - | - |
|
VPPL-3L-3-G14-0L20H-V1-V-S1-6PROPORTIONAL-PRESSURE REGULATOR |
2,061 |
|
Datasheet | VPPL | Bulk | Active | Regulator | 290 PSI (20 bar) | 2.9 ~ 290 PSI (0.2 ~ 20 bar) | 74GPM (282LPM) | 24VDC Supply Voltage | G1/4 | - | Compressed Air, Inert Gas | 5°C ~ 50°C | - | - | - | - |
|
LDM1-1/2-D-MAXI-300MEMBRANE AIR DRYER |
1,933 |
|
Datasheet | D | Bulk | Active | Lubricator | 43.5 ~ 181.3 PSI (3 ~ 12.5 bar) | - | 79GPM (300LPM) | - | G1/2 | - | Compressed Air | 2°C ~ 50°C | - | - | - | - |
Frequently Asked Questions
What are Preparation-Treatment components used for?
Preparation-Treatment components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Preparation-Treatment part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Preparation-Treatment parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.