Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
75KEPS10AFPWLINE FILTER 440VAC 75A CHASS MNT |
1,574 |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 75 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
80KEBS6AFPDLINE FILTER 440VAC 80A CHASS MNT |
3,915 |
|
Datasheet | KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 80 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M8) | - |
|
40 AHV D FPLINE FILTER 40A CHASSIS MOUNT |
1,644 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 40 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
100KEMS10ABSDLINE FLTR 440VAC 100A CHASS MNT |
4,391 |
|
Datasheet | KEM-BS | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
80KEBS10AFPDLINE FILTER 440VAC 80A CHASS MNT |
1,854 |
|
Datasheet | KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 80 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
75KEHD10BBSDLINE FILTER 520VAC 75A CHASS MNT |
4,429 |
|
Datasheet | KEH-BS | Bulk | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 75 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
100KEPS10ABSWLINE FLTR 440VAC 100A CHASS MNT |
4,282 |
|
Datasheet | KEP-BS | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
75KEPS10BFPWLINE FILTER 520VAC 75A CHASS MNT |
4,524 |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 75 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
80KESS10AFPWLINE FILTER 440VAC 80A CHASS MNT |
4,057 |
|
Datasheet | KES | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 80 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
30 AHV D BSLINE FILTER 130A CHASSIS MOUNT |
1,416 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 130 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
75KEVD10BBSWLINE FILTER 520VAC 75A CHASS MNT |
2,523 |
|
Datasheet | KEV-BS | Bulk | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 75 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
100KEMS10BBSDLINE FLTR 520VAC 100A CHASS MNT |
3,239 |
|
Datasheet | KEM-BS | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
80KEBS6BFPDLINE FILTER 520VAC 80A CHASS MNT |
1,716 |
|
Datasheet | KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 80 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M8) | - |
|
100KEPS10BBSWLINE FLTR 520VAC 100A CHASS MNT |
3,410 |
|
Datasheet | KEP-BS | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
100KEBS6AFPDLINE FLTR 440VAC 100A CHASS MNT |
2,902 |
|
Datasheet | KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M10) | - |
|
100KEMS10AFPDLINE FLTR 440VAC 100A CHASS MNT |
3,282 |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 100 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
42 AHV D BSLINE FILTER 42A CHASSIS MOUNT |
1,149 |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Two Stage | - | - | 750 V | 760 V | 42 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
100KEPS10AFPWLINE FLTR 440VAC 100A CHASS MNT |
2,331 |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 100 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
100KEBS10AFPDLINE FLTR 440VAC 100A CHASS MNT |
2,704 |
|
Datasheet | KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
80KESS10BFPWLINE FILTER 520VAC 80A CHASS MNT |
2,674 |
|
Datasheet | KES | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 80 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.