| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FIN1700E.018.MLINE FILTER 18A CHASSIS MOUNT |
4,945 |
|
Datasheet | FIN1700E | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 3.1 kV | 2.3 kV | 18 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN21.003.MLINE FILTER 250VAC 3A DIN RAIL |
3,436 |
|
Datasheet | FIN21 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
FIN33.020.FLINE FILTER 250VAC 20A CHASS MNT |
1,345 |
|
Datasheet | FIN33 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | 50/60Hz | Medical | cCSAus, CE | -40°C ~ 85°C | Chassis Mount | Quick Connect | - |
|
FIN1240.080.MLINE FILTER 80A CHASSIS MOUNT |
3,419 |
|
Datasheet | FIN1240 | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 2.9 kV | 2.2 kV | 80 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN26.010.MLINE FILTER 250VAC 10A DIN RAIL |
4,061 |
|
Datasheet | FIN26 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
FIN538S1.280.VLINE FILTER 280A CHASSIS MOUNT |
1,048 |
|
Datasheet | FIN538S1 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 3.2 kV | 2.4 kV | 280 A | 50/60Hz | Regenerative Motor Drive | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
FIN538S1.250.VLINE FILTER 250A CHASSIS MOUNT |
4,059 |
|
Datasheet | FIN538S1 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 3.2 kV | 2.4 kV | 250 A | 50/60Hz | Regenerative Motor Drive | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
FIN1500.080.VLINE FILTER 80A CHASSIS MOUNT |
4,148 |
|
Datasheet | FIN1500 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 2.9 kV | 2.2 kV | 80 A | 50/60Hz | Regenerative Motor Drive | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
FIN538S1.075.MLINE FILTER 75A CHASSIS MOUNT |
3,567 |
|
Datasheet | FIN538S1 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 3.2 kV | 2.4 kV | 75 A | 50/60Hz | Regenerative Motor Drive | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN538S1.130.MLINE FILTER 130A CHASSIS MOUNT |
4,390 |
|
Datasheet | FIN538S1 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 3.2 kV | 2.4 kV | 130 A | 50/60Hz | Regenerative Motor Drive | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN1700E.070.MLINE FILTER 70A CHASSIS MOUNT |
2,248 |
|
Datasheet | FIN1700E | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 3.1 kV | 2.3 kV | 70 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN27.020.MLINE FILTER 250VAC 20A DIN RAIL |
1,072 |
|
Datasheet | FIN27 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
FIN1240.050.MLINE FILTER 50A CHASSIS MOUNT |
1,618 |
|
Datasheet | FIN1240 | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 2.9 kV | 2.2 kV | 50 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN33.040.VLINE FILTER 250VAC 40A CHASS MNT |
3,874 |
|
Datasheet | FIN33 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 40 A | 50/60Hz | Medical | cCSAus, CE | -40°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
FIN1240.500.BLINE FILTER 500A CHASSIS MOUNT |
1,516 |
|
Datasheet | FIN1240 | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 2.9 kV | 2.2 kV | 500 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Post | - |
|
FIN1700EG.055.MLINE FILTER 55A CHASSIS MOUNT |
2,957 |
|
Datasheet | FIN1700EG | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 3.1 kV | 2.3 kV | 55 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN1700.032.MLINE FILTER 32A CHASSIS MOUNT |
1,238 |
|
Datasheet | FIN1700 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 3.2 kV | 2.4 kV | 32 A | 50/60Hz | General Purpose | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN1740ESM.072.MLINE FILTER 72A CHASSIS MOUNT |
4,321 |
|
Datasheet | FIN1740ESM | Bulk | Active | Three Phase (Wye) | Single Stage | - | - | 3.1 kV | 2.3 kV | 72 A | 50/60Hz | Medical | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FIN1500.050.VLINE FILTER 50A CHASSIS MOUNT |
4,892 |
|
Datasheet | FIN1500 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 2.9 kV | 2.2 kV | 50 A | 50/60Hz | Regenerative Motor Drive | CE, CSA, cURus, UL | -40°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
FIN230SP.001.MLINE FILTER 1000VDC DIN RAIL |
2,498 |
|
Datasheet | FIN230SP | Bulk | Active | Three Phase (Delta) | Single Stage | 1000V (1kV) | - | 3.3 kV | 2.4 kV | - | 50/60Hz | General Purpose | CE, CSA, cURus, UL | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.