Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FLLD3800APZI1LINE FILTER 800A CHASSIS MOUNT |
2,237 |
|
Datasheet | FLLD3 – PH | Bulk | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 800 A | 50 ~ 60Hz | General Purpose | UL | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FTB-80-203-HLINE FILTER 500VAC 80A CHASS MNT |
2,945 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-80-324-HLINE FILTER 500VAC 80A CHASS MNT |
3,012 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-80-663-HLINE FILTER 500VAC 80A CHASS MNT |
1,227 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN2211-1500-99-C30-R55LINE FILTER 1000VDC 1.5KA CHASS |
4,097 |
|
Datasheet | FN 2211 | Box | Active | DC | Single Stage | 1000V (1kV) | - | - | - | 1.5 kA | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143B0400S024LINE FILTER 690/400VAC 400A CHAS |
3,808 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | 690V, 400V | - | - | 400 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
FN5010-60-99LINE FILTER 60A CHASSIS MOUNT |
1,747 |
|
Datasheet | FN 5010 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 230 V | 400 V | 60 A | - | Inverters, Power Drive Systems | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | 1.1mH |
|
FTB-100-203-HLINE FLTR 500VAC 100A CHASS MNT |
4,310 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-100-324-HLINE FLTR 500VAC 100A CHASS MNT |
3,313 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-100-663-HLINE FLTR 500VAC 100A CHASS MNT |
2,634 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84142C1250S081LINE FILTER 1500VDC 600VAC CHAS |
2,232 |
|
Datasheet | B84142C | Box | Active | DC | Two Stage | 1500V (1.5kV) | 600V | - | - | 1.25 kA | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FTB-80-203-HSLINE FILTER 500VAC 80A CHASS MNT |
2,260 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-80-324-HSLINE FILTER 500VAC 80A CHASS MNT |
3,604 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-80-663-HSLINE FILTER 500VAC 80A CHASS MNT |
2,241 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
RTEN-5200LINE FILTER 500VAC/VDC 200A CHAS |
3,393 |
|
Datasheet | RTEN | Bulk | Active | Three Phase (Delta) | Single Stage | 500V | 500V | - | - | 200 A | - | General Purpose | EN | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMAC-0F32-1713LINE FILTER 550VAC 17A CHASS MNT |
1,244 |
|
Datasheet | FMAC-Out | Bulk | Active | Three Phase (Delta) | Single Stage | - | 550V | - | - | 17 A | 50 ~ 60Hz | General Purpose | ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84143B0400S021LINE FILTER 760/440VAC 400A CHAS |
3,042 |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | - | - | 400 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
|
RTHB-5150LINE FILTER 500VAC/VDC 150A CHAS |
2,478 |
|
Datasheet | RTHB | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | 500V | - | - | 150 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-100-203-HSLINE FLTR 500VAC 100A CHASS MNT |
2,265 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTB-100-324-HSLINE FLTR 500VAC 100A CHASS MNT |
2,891 |
|
Datasheet | FTB | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.