Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AGPH24015LINE FILTER 240VAC 15A CHASS MNT |
4,428 |
|
Datasheet | - | Bulk | Active | Single Phase | - | - | 240V | - | - | 15 A | - | General Purpose | UL | - | Chassis Mount | Terminal Block | - |
|
FN3287-160-40-C21-R65LINE FILTER 530/305VAC 160A CHAS |
3,535 |
|
Datasheet | FN 3287 | Bulk | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 160 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
3-138-343LINE FILTER 230A CHASSIS MOUNT |
3,393 |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | - | 520 V | 760 V | 230 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
FN3310HV-250-99-R5LINE FILTER 250A CHASSIS MOUNT |
1,362 |
|
Datasheet | FN 3310 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 440 V | 760 V | 250 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
F3480T060LINE FILTER 480VAC 60A CHASS MNT |
3,628 |
|
Datasheet | F3480 | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 60 A | 50/60Hz | General Purpose | CE, UR | - | Chassis Mount | Terminal Block | - |
|
|
FLLD3250APHI1LINE FLTR 690VAC 250A CHASS MNT |
2,337 |
|
Datasheet | FLLD3 | Bulk | Last Time Buy | Three Phase (Delta) | Two Stage | - | 690V | - | - | 250 A | 50/60Hz | General Purpose | EN, UL | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
DC150-4FFLINE FILTER, 3-PHASE, 250VAC, 15 |
1,055 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
B84142C0320S081LINE FLTR 1500VDC 320A CHASS MNT |
1,393 |
|
Datasheet | B84142C | Bulk | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 320 A | 50 ~ 60Hz | Converter | cUL, cUR, UL,UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
DE150-4FFLINE FILTER, 3-PHASE, 480VAC, 15 |
2,799 |
|
Datasheet | DE | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 150 A | 47Hz, 63Hz | General Purpose | cCSAus | - | Chassis Mount | Threaded Post (3/8-16) | - |
|
|
FLLE2250APVI1LINE FLTR 1200VDC 250A CHASS MNT |
4,818 |
|
Datasheet | FLLE2-PV | Bulk | Last Time Buy | DC | Single Stage | 1200V (1.2kV) | - | - | - | 250 A | - | Photovoltaic Inverter | EN, UL | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
3-138-371LINE FILTER 230A CHASSIS MOUNT |
0 |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 230 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
B84142J0320S081LINE FLTR 1KVDC 600VAC 320A CHAS |
2,003 |
|
Datasheet | B84142 | Box | Active | DC | Two Stage | 1000V (1kV) | 600V | - | - | 320 A | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
TPYA150-4FFLINE FILTER, 3-PHASE WYE, 250/44 |
4,940 |
|
Datasheet | TPY | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 250 V | 440 V | 150 A | 47Hz, 63Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Threaded Post (M5) | - |
|
|
160TYT8-1LINE FILTER 520VAC CHASSIS MOUNT |
1,695 |
|
Datasheet | TYT | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | - | 50/60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block | 500µH |
|
|
200TYSS104LINE FILTER 480VAC CHASSIS MOUNT |
4,653 |
|
Datasheet | TYS | Box | Active | Three Phase (Wye) | Single Stage | - | 480V | - | - | - | 50/60Hz | General Purpose | - | - | Chassis Mount | Terminal Post | 3µH |
|
FN3288HVIT-125-35-C26-R60LINE FLTR 760VAC 125A CHASS MNT |
1,181 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 125 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84143A0150R000LINE FILTER 480/275VAC 150A CHAS |
2,948 |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 275V | 275 V | 480 V | 150 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, ENEC, UL | - | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
FN5420-18-89-E0XXTLINE FILTER 18A CHASSIS MOUNT |
2,198 |
|
Datasheet | FN 5420 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 480 V | 530 V | 18 A | DC ~ 60Hz | Regenerative Motor Drive | CE, cURus, UKCA | -40°C ~ 70°C | Chassis Mount | Terminal Block | 2.45mH |
|
FN3288-160-40-C21-R65LINE FILTER 530/305VAC 160A CHAS |
1,146 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 160 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN258HV-100-35LINE FILTER 100A CHASSIS MOUNT |
3,381 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 100 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.