| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FMBC-A91S-5512LINE FILTER 480V/520VAC 55A CHAS |
4,974 |
|
Datasheet | FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 55 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.8mH, L2 - 13µH |
|
FN3287-100-35-C21-R65LINE FILTER 530/305VAC 100A CHAS |
3,362 |
|
Datasheet | FN 3287 | Bulk | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 100 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN5060-24-84LINE FILTER 24A CHASSIS MOUNT |
4,891 |
|
Datasheet | FN 5060 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 500 V | 550 V | 24 A | DC ~ 60Hz | Regenerative Motor Drive | CE, cURus | -25°C ~ 100°C | Chassis Mount | Terminal Block | 98µH |
|
80KEHD10BFPDLINE FILTER 520VAC 80A CHASS MNT |
1,367 |
|
Datasheet | KEH | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 80 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FSB-20-324-HLINE FILTER 500VAC 20A CHASS MNT |
3,165 |
|
Datasheet | FSB | Box | Active | Three Phase (Delta) | Two Stage | - | 500V | - | - | 20 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B86305L0230S000LINE FILTER 230A CHASSIS MOUNT |
2,723 |
|
Datasheet | B86305 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | - | 520 V | 230 A | 50 ~ 60Hz | Converter | cURus | -25°C ~ 100°C | Chassis Mount | Terminal Block | 130µH |
|
FN510-24-33LINE FILTER 24A CHASSIS MOUNT |
3,122 |
|
Datasheet | FN 510 | Tray | Obsolete | Three Phase (Delta) | - | - | - | 288 V | 500 V | 24 A | - | General Purpose | - | -25°C ~ 70°C | Chassis Mount | Terminal Block | - |
|
FN3400-24-33LINE FILTER 24A CHASSIS MOUNT |
2,441 |
|
Datasheet | FN 3400 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 24 A | DC ~ 60Hz | General Purpose | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FTA-80-104LINE FILTER 500VAC 80A CHASS MNT |
1,838 |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-80-155LINE FILTER 500VAC 80A CHASS MNT |
4,868 |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-80-223LINE FILTER 500VAC 80A CHASS MNT |
1,828 |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-80-683LINE FILTER 500VAC 80A CHASS MNT |
1,537 |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84142A0180S081LINE FLTR 800VDC 180A CHASS MNT |
1,202 |
|
Datasheet | B84142A | Bulk | Active | Single Phase | Two Stage | 800V | - | - | - | 180 A | 50 ~ 60Hz | Converter | cUL, cUR, UL,UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3288HVIT-80-34-C26-R60LINE FILTER 760VAC 80A CHASS MNT |
4,400 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84312C0050B121LINE FILTER 100VAC 2A CHASS MNT |
1,395 |
|
Datasheet | B84312 | Box | Active | Single Phase | Three Stage | - | 100V | 100 V | 100 V | 2 A | - | General Purpose | - | -25°C ~ 40°C | Chassis Mount | Threaded Post (M6) | - |
|
B84312C0050B031LINE FILTER 100VAC 3A CHASS MNT |
4,772 |
|
Datasheet | B84312 | Box | Active | Single Phase | Three Stage | - | 100V | 100 V | 100 V | 3 A | - | General Purpose | - | -25°C ~ 40°C | Chassis Mount | Threaded Post (M6) | - |
|
B84312F0050B031LINE FILTER 100VAC 3A CHASS MNT |
2,679 |
|
Datasheet | B84312 | Box | Active | Single Phase | Three Stage | - | 100V | 100 V | 100 V | 3 A | - | General Purpose | - | -25°C ~ 40°C | Chassis Mount | Threaded Post (M6) | - |
|
B84312F0050B121LINE FILTER 100VAC 2A CHASS MNT |
2,077 |
|
Datasheet | B84312 | Box | Active | Single Phase | Three Stage | - | 100V | 100 V | 100 V | 2 A | - | General Purpose | - | -25°C ~ 40°C | Chassis Mount | Threaded Post (M6) | - |
|
AGCF12010-CPLINE FILTER 120VAC 10A CHASS MNT |
1,348 |
|
Datasheet | - | Bulk | Active | Single Phase | - | - | 120V | - | - | 10 A | - | General Purpose | UL | - | Chassis Mount | Terminal Block | - |
|
TAC-100-103LINE FLTR 500VAC 100A CHASS MNT |
3,510 |
|
Datasheet | TAC | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.