Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
B84143A0035R410LINE FILTER 35A CHASSIS MOUNT |
2,219 |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 520 V | 300 V | 35 A | 50 ~ 60Hz | Converter | cUL, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
IE-203LINE FILTER 240VAC 3A DIN RAIL |
2,292 |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | 240V | - | - | 3 A | 47Hz, 63Hz | General Purpose | CE, cUL, UL | -40°C ~ 45°C | DIN Rail | Terminal Block | - |
|
SF1932LINE FILTER ASSY |
3,803 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
TPYA45-4FFLINE FILTER, 3-PHASE WYE, 250/44 |
3,141 |
|
Datasheet | TPY | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 250 V | 440 V | 45 A | 47Hz, 63Hz | General Purpose | CSA, UR, VDE | - | Chassis Mount | Threaded Post (M5) | - |
|
FN3288HV-63-53-C25-R65LINE FILTER 63A CHASSIS MOUNT |
3,298 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 440 V | 760 V | 63 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
DE45-4FFLINE FILTER, 3-PHASE, 480VAC, 45 |
2,065 |
|
Datasheet | DE | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 45 A | 47Hz, 63Hz | General Purpose | cCSAus | - | Chassis Mount | Threaded Post (1/4-20) | - |
|
|
LF-330LINE FILTER 250VAC/VDC 30A CHASS |
3,434 |
|
Datasheet | LF | Box | Obsolete | Three Phase (Delta) | Two Stage | 250V | 250V | - | - | 30 A | - | General Purpose | - | -20°C ~ 55°C | Chassis Mount | Threaded Post (M4) | - |
|
FN5420-5.9-88-E0XXTLINE FILTER 5.9A CHASSIS MOUNT |
1,973 |
|
Datasheet | FN 5420 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 480 V | 530 V | 5.9 A | DC ~ 60Hz | Regenerative Motor Drive | CE, cURus, UKCA | -40°C ~ 70°C | Chassis Mount | Terminal Block | 7.48mH |
|
3VAQ8FLINE FILTER 250VAC 3A CHASS MNT |
2,565 |
|
Datasheet | AQ | Bulk | Obsolete | Single Phase | Three Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | CSA, UR | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Wire Leads | - |
|
75KEBS6AFPDLINE FILTER 440VAC 75A CHASS MNT |
1,907 |
|
Datasheet | KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 75 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M8) | - |
|
75KEMS10ABSDDMLINE FILTER 440VAC 75A CHASS MNT |
4,841 |
|
Datasheet | KEM-BS | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 75 A | 50 ~ 60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBC-A91R-4212LINE FILTER 480V/520VAC 42A CHAS |
1,484 |
|
Datasheet | FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 42 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.3mH, L2 - 10µH |
|
AGCF02410LINE FILTER 24VDC 10A CHASS MNT |
3,898 |
|
Datasheet | - | Bulk | Active | Single Phase | - | 24V | - | - | - | 10 A | 50/60Hz | General Purpose | CSA, UL | - | Chassis Mount | Terminal Block | - |
|
FN5010-2.5-99LINE FILTER 2.5A CHASSIS MOUNT |
2,038 |
|
Datasheet | FN 5010 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 230 V | 400 V | 2.5 A | - | Inverters, Power Drive Systems | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | 22.4mH |
|
FN3840-50-53-C35-R65LINE FILTER 50A CHASSIS MOUNT |
1,498 |
|
Datasheet | FN3840 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 305 V | 530 V | 50 A | 50/60Hz | Regenerative Motor Drive | CE, ENEC, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84742A0130R190LINE FLTR 1KVDC 500VAC 130A CHAS |
4,374 |
|
Datasheet | B84742 | Box | Active | Single Phase | Single Stage | 1000V (1kV) | 500V | - | - | 130 A | 50/60Hz | Photovoltaic Inverter | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FN351-50-33LINE FILTER 50A CHASSIS MOUNT |
4,377 |
|
Datasheet | FN 351 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 250 V | 440 V | 50 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
TAH-50-223EMI FILTER |
3,762 |
|
Datasheet | TAH | Bulk | Active | Three Phase (Delta) | Single Stage | - | 528V | - | - | 50 A | - | General Purpose | cURus, ENEC, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143V0007R231LINE FILTER 230V/400VAC 7A CHASS |
4,683 |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | 230V, 400V | - | - | 7 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
RTHB-5050LINE FILTER 500VAC/VDC 50A CHASS |
3,126 |
|
Datasheet | RTHB | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | 500V | - | - | 50 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.