| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
FN256-8-46LINE FILTER 8A CHASSIS MOUNT |
3,733 |
|
Datasheet | FN 256 | Tray | Obsolete | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 8 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
16TDT2LINE FILTER 480VAC CHASSIS MOUNT |
4,999 |
|
Datasheet | TDT | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | - | 50/60Hz | General Purpose | - | - | Chassis Mount | Terminal Block | 5.2mH |
|
|
25TYT8-2LINE FILTER 520VAC CHASSIS MOUNT |
4,797 |
|
Datasheet | TYT | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | - | 50/60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block | L1 - 1.6mH, L2 - 6µH |
|
FN258L-7-07LINE FILTER 7A CHASSIS MOUNT |
3,989 |
|
Datasheet | FN 258 | Tray | Obsolete | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 7 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
2788977LINE FILTER 264VAC 10A DIN RAIL |
4,556 |
|
Datasheet | - | Bulk | Obsolete | Single Phase | Single Stage | - | 264V | - | - | 10 A | 50/60Hz | General Purpose | GOST, UR, VDE | -25°C ~ 100°C | DIN Rail | Terminal Block | 1.8mH |
|
FN3288HV-20-33-C25-R65LINE FILTER 20A CHASSIS MOUNT |
1,812 |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 440 V | 760 V | 20 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
RSAN-2060LINE FILTER 250VAC/VDC 60A CHASS |
2,394 |
|
Datasheet | RSAN | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 60 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
10KEHD10BFPDLINE FILTER 520VAC 10A CHASS MNT |
1,533 |
|
Datasheet | KEH | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 10 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
LF-310LINE FILTER 250VAC/VDC 10A CHASS |
3,484 |
|
Datasheet | LF | Box | Obsolete | Three Phase (Delta) | Two Stage | 250V | 250V | - | - | 10 A | - | General Purpose | UL | -20°C ~ 45°C | Chassis Mount | Threaded Post (M4) | - |
|
6609974-5LINE FILTER 16A CHASSIS MOUNT |
3,821 |
|
Datasheet | FCD | Box | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 277 V | 480 V | 16 A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
6609069-6LINE FILTER 250VAC 50A CHASS MNT |
3,653 |
|
Datasheet | FC | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 50 A | 50/60Hz | Inverters, Power Drive Systems | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
TAC-50-103LINE FILTER 500VAC 50A CHASS MNT |
1,802 |
|
Datasheet | TAC | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 50 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B86305L0035R000LINE FILTER 520VAC 35A CHASS MNT |
1,052 |
|
Datasheet | B86305 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 35 A | 50/60Hz | Converter | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | 840µH |
|
20KESS6BFPWLINE FILTER 520VAC 16A CHASS MNT |
2,854 |
|
Datasheet | KES | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 16 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
B84144A0025R140LINE FILTER 25A CHASSIS MOUNT |
2,114 |
|
Datasheet | B84144 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 520 V | 300 V | 25 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FSB-30-254-UEMI FILTER |
1,010 |
|
Datasheet | FSB | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | - | 528 V | 30 A | 50/60Hz | Regenerative Motor Drive | cURus, ENEC, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
10KEVD10BFPWLINE FILTER 520VAC 10A CHASS MNT |
1,706 |
|
Datasheet | KEV | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 10 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
16KEHD10ABSDHMLINE FILTER 440VAC 16A CHASS MNT |
4,504 |
|
Datasheet | KEH-BS | Box | Active | Three Phase (Delta) | Two Stage | - | 440V | - | - | 16 A | 50 ~ 60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN686-25-23LINE FILTER 250VAC 25A CHASS MNT |
4,399 |
|
Datasheet | FN 685 | Tray | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 25 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1.35mH |
|
|
25TDT2LINE FILTER 480VAC CHASSIS MOUNT |
3,486 |
|
Datasheet | TDT | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | - | 50/60Hz | General Purpose | - | - | Chassis Mount | Terminal Block | 2.2mH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.