Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
42TDVST2LINE FILTER 480VAC 42A CHASS MNT |
4,489 |
|
Datasheet | TDV | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 42 A | 50/60Hz | General Purpose | cURus, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | 600µH |
|
3-104-582LINE FILTER 36A CHASSIS MOUNT |
1,016 |
|
Datasheet | FMAC NEO | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 36 A | 50 ~ 60Hz | General Purpose | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
3-104-583LINE FILTER 50A CHASSIS MOUNT |
2,610 |
|
Datasheet | FMAC NEO | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 50 A | 50 ~ 60Hz | General Purpose | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
8KEPS10BFPWLINE FILTER 520VAC 8A CHASS MNT |
1,005 |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 8 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
5500.2240LINE FILTER 125V/250VAC 30A CHAS |
4,193 |
|
Datasheet | FMBB | Bulk | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 30 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cULus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBD-395B-3614LINE FILTER 760VAC 36A CHASS MNT |
4,952 |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 760V | - | - | 36 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
8KEMS10BFPDHMLINE FILTER 520VAC 8A CHASS MNT |
3,182 |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 8 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
RTCN-5050LINE FILTER 500VAC/VDC 50A CHASS |
4,055 |
|
Datasheet | RTCN | Bulk | Active | Three Phase (Delta) | Single Stage | 500V | 500V | - | - | 50 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
MBS-1220-22LINE FILTER 250VAC/VDC 20A CHASS |
1,729 |
|
Datasheet | MBS | Bulk | Obsolete | Single Phase | Single Stage | 250V | 250V | - | - | 20 A | - | General Purpose | CSA, UL, VDE | -25°C ~ 85°C | Chassis Mount | Threaded Post (M4) | - |
|
SF1908LINE FILTER ASSY |
3,481 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
K5-3EMI FILTER, SINGLE PHASE, 5A |
3,219 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
16TYT8LINE FILTER 480VAC CHASSIS MOUNT |
4,650 |
|
Datasheet | TYT | Box | Active | Three Phase (Wye) | Single Stage | - | 480V | - | - | - | 50/60Hz | General Purpose | - | - | Chassis Mount | Terminal Block | 1.2mH |
|
FMBD-345B-5014LINE FILTER 760VAC 50A CHASS MNT |
4,595 |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 760V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBD-395B-5014LINE FILTER 760VAC 50A CHASS MNT |
4,027 |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 760V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FN685-16-03LINE FILTER 250VAC 16A CHASS MNT |
1,350 |
|
Datasheet | FN 685 | Tray | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | 2.3mH |
|
FN2412H-45-33LINE FILTER DIN RAIL |
1,667 |
|
Datasheet | FN 2412 | Tray | Obsolete | Single Phase | Single Stage | - | - | - | - | - | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
7KEPS10BBSWVMLINE FILTER 520VAC 7A CHASS MNT |
3,287 |
|
Datasheet | KEP-BS | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 7 A | 50 ~ 60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
8KEMS10BFPDVMLINE FILTER 520VAC 8A CHASS MNT |
2,434 |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 8 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
MC1306DINLINE FILTER 6A DIN RAIL |
1,310 |
|
Datasheet | MC13 | Bulk | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | 500 V | 6 A | - | General Purpose | CSA, UL, VDE | -25°C ~ 85°C | DIN Rail | Terminal Block | - |
|
|
08TYT8-1LINE FILTER 520VAC CHASSIS MOUNT |
2,248 |
|
Datasheet | TYT | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | - | 50/60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block | 2.4mH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.