Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FLLE2032AUMILINE FILTER 300VAC/VDC 32A CHASS |
1,470 |
|
Datasheet | FLLE2-U | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 32 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 1.3mH |
|
NBH-16-101LINE FILTER 250VAC/VDC 16A CHASS |
1,749 |
|
Datasheet | NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
NBH-16-471LINE FILTER 250VAC/VDC 16A CHASS |
2,976 |
|
Datasheet | NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
NBH-16-000LINE FILTER 250VAC/VDC 16A CHASS |
3,176 |
|
Datasheet | NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN2090B-30-08LINE FILTER 250VAC/VDC 30A CHASS |
2,471 |
|
Datasheet | FN 2090 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 30 A | 50 ~ 60Hz | Medical | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 1.5mH |
|
RTEN-2006LINE FILTER 6A CHASSIS MOUNT |
1,827 |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 6 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
7KEMS10ABSDDMLINE FILTER 440VAC 7A CHASS MNT |
4,721 |
|
Datasheet | KEM-BS | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 7 A | 50 ~ 60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
04TDPS6(D)LINE FILTER 4A DIN RAIL |
1,126 |
|
Datasheet | TDP | Box | Active | Three Phase (Delta) | Single Stage | - | - | - | - | 4 A | - | General Purpose | cURus, ENEC | - | DIN Rail | Terminal Block | 40mH |
|
F1760DD20LINE FILTER 250VAC 20A CHASS MNT |
2,467 |
|
Datasheet | F1760 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, TUV, UR | - | Chassis Mount | Threaded Post (8-32) | - |
|
F1770DD20LINE FILTER 250VAC 20A CHASS MNT |
3,958 |
|
Datasheet | F1770 | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, TUV, UR | - | Chassis Mount | Threaded Post (8-32) | - |
|
RTEN-2010LINE FILTER 10A CHASSIS MOUNT |
3,388 |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 10 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
MXB-1210-33LINE FILTER 250VAC/VDC 10A CHASS |
4,066 |
|
Datasheet | MXB | Bulk | Obsolete | Single Phase | Two Stage | 250V | 250V | - | - | 10 A | - | General Purpose | CSA, UL, VDE | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
6609976-3LINE FILTER 250VAC 12A CHASS MNT |
1,168 |
|
Datasheet | FC | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 12 A | 50/60Hz | Inverters, Power Drive Systems | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
FN2070A-25-08LINE FILTER 250VAC/VDC 25A CHASS |
4,640 |
|
Datasheet | FN 2070 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 25 A | DC ~ 400Hz | Safety | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 2mH |
|
|
10TDS6DLINE FILTER 440VAC 10A CHASS MNT |
2,700 |
|
Datasheet | TD | Box | Active | Three Phase (Delta) | Two Stage | - | 440V | - | - | 10 A | 50/60Hz | General Purpose | - | - | Chassis Mount | Threaded Post (M6) | L1 - 122µH, L2 - 2.8mH |
|
|
06TDPS6(D)LINE FILTER 6A DIN RAIL |
2,578 |
|
Datasheet | TDP | Box | Active | Three Phase (Delta) | Single Stage | - | - | - | - | 6 A | - | General Purpose | cURus, ENEC | - | DIN Rail | Terminal Block | 23mH |
|
MXB-1220-33LINE FILTER 250VAC/VDC 20A CHASS |
3,793 |
|
Datasheet | MXB | Bulk | Obsolete | Single Phase | Two Stage | 250V | 250V | - | - | 20 A | - | General Purpose | CSA, UL, VDE | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
8KEMS10AFPDLINE FILTER 440VAC 8A CHASS MNT |
2,232 |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 8 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
4-1609037-0LINE FILTER 250VAC 20A CHASS MNT |
2,780 |
|
Datasheet | HT | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 2.88mH |
|
FN2090Z-30-08LINE FILTER 250VAC/VDC 30A CHASS |
2,205 |
|
Datasheet | FN 2090 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 30 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 1.5mH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.