Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
NBH-10-331LINE FILTER 250VAC/VDC 10A CHASS |
4,441 |
|
Datasheet | NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
NBH-10-471LINE FILTER 250VAC/VDC 10A CHASS |
2,961 |
|
Datasheet | NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
NBH-10-681LINE FILTER 250VAC/VDC 10A CHASS |
4,480 |
|
Datasheet | NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 10 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FLLE2020AUDDLINE FILTER 300VAC/VDC 20A CHASS |
4,520 |
|
Datasheet | FLLE2-U | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 20 A | 50/60Hz | General Purpose | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 2.7mH |
|
|
6VN1LINE FILTER 250VAC 6A CHASS MNT |
4,161 |
|
Datasheet | N | Bulk | Last Time Buy | Single Phase | Single Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 4.47mH |
|
|
6EP3LINE FILTER 250VAC 6A CHASS MNT |
2,247 |
|
Datasheet | EP | Bulk | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | - |
|
MZ1206DINLINE FILTER 250VAC 6A DIN RAIL |
1,749 |
|
Datasheet | MZ12 | Bulk | Obsolete | Single Phase | Single Stage | - | 250V | - | - | 6 A | - | General Purpose | CSA, SEMKO, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - |
|
AHM-30LINE FILTER 250VAC 30A CHASS MNT |
1,007 |
|
Datasheet | AHM | Box | Obsolete | Single Phase | Two Stage | - | 250V | - | - | 30 A | 50/60Hz | Medical | CE, UR | -25°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
|
GT-215ULINE FILTER 250VAC 15A CHASS MNT |
2,789 |
|
Datasheet | GT | Box | Obsolete | Single Phase | Single Stage | - | 250V | - | - | 15 A | - | General Purpose | - | -20°C ~ 55°C | Chassis Mount | Threaded Post (M4) | - |
|
FN2090-16-07LINE FILTER 250VAC/VDC 16A CHASS |
1,925 |
|
Datasheet | FN 2090 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 16 A | 50 ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 4mH |
|
FN2030BZ-30-08LINE FILTER 250VAC/VDC 30A CHASS |
4,259 |
|
Datasheet | FN 2030 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 30 A | 50 ~ 60Hz | Medical | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 2mH |
|
FLLE2020ASMILINE FILTER 300VAC/VDC 20A CHASS |
2,519 |
|
Datasheet | FLLE2-S | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 20 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 2mH |
|
F1300DD20LINE FILTER 250VAC 20A CHASS MNT |
2,820 |
|
Datasheet | F1300 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Threaded Post (1/4-20) | - |
|
F2800AA10LINE FILTER 250VAC 10A CHASS MNT |
1,545 |
|
Datasheet | F2800 | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Quick Connect | - |
|
|
B84112G0000M125LINE FILTER 250VAC/VDC 25A CHASS |
2,262 |
|
Datasheet | B84112G | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 25 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M5) | 1.6mH |
|
TKA-007LINE FILTER 440VAC 7A CHASS MNT |
1,676 |
|
Datasheet | TK | Box | Obsolete | Three Phase (Delta) | Single Stage | - | 440V | - | - | 7 A | 50/60Hz | Inverters, Power Drive Systems | cCSAus, CE, UR | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN2070M-10-08LINE FILTER 250VAC/VDC 10A CHASS |
4,596 |
|
Datasheet | FN 2070 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 10 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 4.5mH |
|
MC1220LLINE FILTER 250VAC 20A CHASS MNT |
4,952 |
|
Datasheet | MC | Bulk | Obsolete | Single Phase | Single Stage | - | 250V | - | - | 20 A | - | General Purpose | CSA, SEMKO, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
6609026-9LINE FILTER 250VAC 30A CHASS MNT |
1,973 |
|
Datasheet | K | Bulk | Obsolete | Single Phase | Single Stage | - | 250V | - | - | 30 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 690µH |
|
G10-10ELINE FILTER, 250VAC, 10A, CHASSI |
2,007 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.